Electric wns oil or fired steam boiler to be taken by each of the cathodic protection measures components of the electric steam boiler is made of different materials. In order to prevent galvanic corrosion, cathodic protection measures must be taken. Sewage treatment electric steam boilers. Bottom electric steam boiler blowdown can prevent flue gas condensation. Since the flue gas is flue gas condensation (diesel or natural gas) and the flue gas temperature in the aqueous too low, water generated. A portion of the moisture is discharged from the chimney, the chimney wall is absorbed, the rest is deposited on the bottom of the chimney. Water produced by the following factors influence: flue gas temperature (efficiency 91%, the flue gas must be at a temperature of 170 ℃) where the total surface area heat chimney, chimney and chimney material. Maintenance of the burner. Electric steam boiler and burner maintenance, repair after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion in the boiler memory stay too long. We first opened when an electric steam boiler burner door, the rear housing panel removed, unscrew the screws electric steam boiler cleaning the rear opening. Clean fuel gas piping with a wire brush. With a soft brush to clean the combustion chamber. Electric steam boiler to remove residue in the boiler, the cleaning opening is screwed on the screw, closing the burner door seal check is complete. If electric steam boilers installed in areas where temperatures below 0 ℃ must take the following precautions: If electric steam boiler room outside, the room temperature drops below 15 ℃ or 18 ℃, the electric steam boiler running all day long. If no one in the room for a long time, the water should be emptied in electric steam boilers.

Boiler plant equipment as three major important energy conversion device, fuel chemical energy into heat energy, and the pot was heated using thermal energy to become hot water having a sufficient quantity and a mass (steam temperature, steam pressure) steam turbine for use. The Anyang City, the power company to my company to buy a split 2 tons of steam condensing gas wns oil or fired steam boiler for supplying electricity demand. The WNS series split condensing boilers using advanced technology designed to greatly improve the thermal efficiency of the boiler, up to about 96%.

The main difference between the gas boiler and gas wns oil or fired steam boiler What is the main difference between what gas boilers and gas steam boiler is? Nominally, a clear distinction between gas and steam boiler wherein the boiler fuel gas is different. The former use of natural gas, which uses coal. I think a lot of user concerns boiler is why they should cancel gas-fired boiler, because many people have purchased and used the gas boiler. If they switch to gas-fired boiler, it will be a huge expenditure. First, according to the current direction of development of the ecological environment of China, gas boilers will gradually be replaced by gas-fired boiler or other clean and green energy boilers, gradually withdraw from the stage of history. To say a big difference between the gas boiler and gas steam boilers, gas-fired boiler is mainly due to the elimination of environmental protection. From the fuel supply portion, only a gas boiler tube connected to the boiler; gas boiler needs coal field, coal (with or artificial), coal transportation, handling, storage and loading of coal boiler process. It will produce dust, causing serious pollution to the people's living environment. From the point of view of atmospheric emissions, natural gas is very small dust content, substantially negligible; high ash content of coal, the ash content of about 10-30%, the combustion smoke. If dust emission reduction facilities, emissions will increase; if more dust removal facilities, the corresponding costs will increase, this is not a long-term solution. In addition, the sulfur content of natural gas is very small, dust removal, desulfurization and denitrification can get gas boilers, gas boilers need only consider the denitrification problem. From the other point of view of waste disposal, natural gas substantially free of other contaminants, especially in city gas. In the case of coal, the coal field (especially small boilers mainly built in the open air) to produce coal slurry water during the rainy season, or sink into groundwater. When entering the surface water, the combustion ash conveyance of dust is generated. Of course, there are differences also in other ways. For small boilers, gas boilers are more energy efficient than gas boilers, equipment flow is simple, small footprint, low operating and maintenance costs, and so on. These are the main difference between the gas boiler and gas steam boilers, as well as the significance out of gas boiler. As can be seen, the use of gas-fired boiler is the trend of the whole society.

When using a chemical plant boilers have what precautions when using chemical plant boiler what precautions? The main industrial production of industrial boiler to provide heat to maintain the power production plant operations, mainly using a wns oil or fired steam boiler of electricity or natural gas industry, the other is based on coal as a raw material by the waste heat recovery operation to maintain the production of traditional electric power industrial boilers, widely used in industrial production. What precautions when using chemical plant boiler? (1) When using industrial boilers, the operator should not only have relevant operational knowledge and skills, but also prohibits unauthorized departure, the boiler is no state in the operation to reduce accidents. Pressure boiler boiler water level is too high or too large. (2) staff to improve the working pressure of industrial boilers, should undergo a rigorous technical evaluation of relevant professional departments, before adjustments. Pressure gauge and safety valve to avoid failure resulting industrial boiler overpressure mislead the operator allowed to adjust. Meanwhile, to strengthen skills related to operating personnel, the timely processing of boiler operation anomalies. (3) prior to use industrial boilers, the boiler should be fully checked structure and current and voltage is within the normal range. To avoid unreasonable boiler structure, poor weld quality, safety accessories related failures caused by industrial accidents occurred in the boiler during operation, and should be sufficient for boiler water treatment prior to use to reduce the incidence of accidents in the run and run.

Other Products