Wns Hot Water Gas Boiler


Wns Hot Water Gas Boiler

Recently, in Jiaxing City in Zhejiang Province Nanhu District, officially launched a comprehensive investigation and action on gas boilers and biomass boilers urban built-up areas, and actively promote the transformation of low nitrogen emission gas-fired boiler, Zhejiang Province, determined to win the Battle of the sky made own contribution.

According to the requirements of the investigation, the South Lake district towns, streets, parks within the jurisdiction of the respective gas boilers and biomass boilers urban area to take home from house to house visits Paimo way, the ecological environment Branch area combined with market regulators issuing a list a verification form inventory management. After the statistics were found in the region with gas boiler 35 units, built-up area of ​​biomass boiler Taiwan.

Meanwhile, Nanhu District will be in more than 500,000 cubic meters of natural gas consumption in the four on-site visits to enterprises as a pilot enterprise low nitrogen transformation operations boilers, ecological environment Branch area of ​​personnel, publicity reform provinces, municipalities and low nitrogen emissions on gas-fired boiler requirement that the premise of ensuring safety in production, natural gas boiler NOx emission after the transformation shall not exceed 50 mg / cubic meter, and listened carefully to the enterprise raised about the difficulties of combustion gas boiler low nitrogen transformation exists.

To speed up the investigation and major renovation large boilers, Nanhu District definite time node, before the end of 2019 business model will complete the transformation of low nitrogen gas boiler, at the same time, the city built-up area of ​​biomass boilers implement ultra-low emissions transformation. Nanhu District will adhere to routine inspections and investigation focused on the combination of concentration and control checks and unannounced visits to combine law enforcement when combined with the daily supervision and wrong, and the law enforcement inspection report from the masses combine to ensure long-term monitoring of boiler regulation implemented.

The main reason gas steam boiler produces smoke which fuel gas steam boiler main cause of smoke. A fuel gas steam boiler: oil, gas oil quality is not good when the gas contains more water, reduce the heat value of the fuel, while producing steam, the furnace temperature tends to decrease, making it difficult to burn, easy to produce smoke. Water and more oil, mainly when unloading rain water into the oil during heating the oil in water vapor penetration. When the oil contains impurities, the impurities unburned produce fine coke, the coke into fine smoke, dust becomes large, and the formation of soot. Impurities contained in the oil and gas, but also affect the pure oil and pure combustion gas generated soot. Oil impurities, mainly due to inappropriate choice of filters or filter difference impurity removal effect. Second, the failure of the fuel atomizing nozzle member main burner fuel oil atomizing nozzle. Atomizing oil burner nozzle fails, affecting the quality of the atomization, easy to poor combustion. 1, the adhesiveness between the bonding surface of the oil and the consequences of failure oil atomizers swirl atomizers and the splitter plate well, leakage will occur, atomized large oil particles, increasing the amount of fuel injection and the like. In this case serious deterioration of the quality of the combustion, the oil droplets have landed on the water wall, stacking up oil coke, partially unburned black smoke into droplets. The tangential swirl chip groove clogging mist causes uneven density distribution in the dense side of the oil mist, combustion air be insufficient. In the more dilute side of the oil mist, combustion air causes severe local excess. Mixed with oil, wind conditions deteriorated significantly, combustion conditions deteriorate, resulting in black smoke. 2, spray atomization slice failure and the consequences of failure to clogging and wear. Nozzle clogging, resulting in blockage of the fuel injection quantity is not glib increase, oil particle size thicker, the effect of fuel poor and black smoke. Wear injection port, a large hole diameter, increasing the amount of fuel injection, increasing the particle size of oil affect combustion efficiency, produce black smoke. The use of artificial gas burner, naphthalene and tar and other impurities will block the nozzles, the influence of gas distribution, resulting in black smoke. Should therefore be cleaned regularly, or clogging of the selected burner. 3, the partition partitioning poor poor, insufficient supply of air into and excess. The amount of air can not meet the requirements of the fuel combustion, so that combustion of fuel can not be sufficiently black smoke. The amount of air, will result in lower combustion temperature, black smoke and fuel difficult to burn. 4, the furnace temperature is too low when starting the furnace, fuel oil steam boiler furnace temperature is too low due to easy black smoke. 5, the furnace hearth product oil is sometimes caused by internal combustion nozzle oil accumulated inside the chamber, the oil reservoir coke black smoke at high temperature. Causes dripping of fuel combustion nozzle: ① The drip just work, just at the operating pressure is too low, the oil will flow from the nozzle, instead of the discharge. The reason for low oil pressure is a solenoid valve, the valve is clogged filter or the like or failure caused by contamination. ② In the dripping process work, probably because the relative position of burner nozzle mounting head too far, improper ignition electrode position, the oil into the atomizer, the nozzle holder is mounted is not tight, nozzle dirty, low oil pressure caused. ③ When the dripping stopped, because the line between the pump and the air nozzle, electromagnetic valve or a hydraulic valve or dirty failure. 6, the furnace flue purged countless consequences when the furnace flue remnants of oil and gas, when gas purging endless, high temperatures encountered in the explosion and black smoke. 7, the furnace smoke, sparks, the furnace pressure is too ①; ② inappropriate choice of the burner, the burner flame is too long or too much power; ③ improper combustion ratio, there are more to produce products of incomplete combustion; ④ atomization quality is not good nozzle or improper installation location, or affect the combustion flame into the furnace off port; ⑤ flue is blocked, poor smoke; ⑥ a secondary air mismatches; irrational ⑦ furnace structure; ⑧ oil spray angle is selected from with improper.

Tail secondary combustion flue how to deal with the phenomenon of a sharp increase in rear of the boiler flue secondary combustion flue temperature location and later. 2, the furnace, the flue abrupt change in negative pressure, flue gas is not tight at the smoke, the Mars. 3, air preheater large current swing bearing housing temperature, severe Jam occurs. 4, air preheater fire alarm issue. 5, steam temperature, economizer outlet water temperature, the air temperature rises abnormally. 6, induced draft fan vanes automatically open a large, Fan current rise. 7, as the combustion side, both sides of the smoke temperature difference increases. Reason 1, through the coarse fine grinding coal, coal poor uniformity, improper adjustment of combustion, combustion of fuel is insufficient, serious mechanical incomplete combustion, and high levels of combustible ash accumulated in the back pass. 2, an oil burner or an oil poor atomization, so that unburned droplets deposited in the flue. 3, prolonged low load operation of boiler, the furnace temperature is too low or too small amount of excess air resulting in incomplete combustion of coal or oil accumulated in the tail. 4, after the shutdown of the fuel leakage into the furnace and accumulates or after shutdown and to insufficient MFT furnace purge unburnt coal or oil accumulation at the end of the tail. 5, soot blower failure, long-term put into operation is not normal. 1 process, when a slight secondary combustion, exhaust gas temperature does not rise within 20 ℃ normal smoking temperature should be checked immediately paragraphs, the combustion site and judge whether the secondary steam soot blowing. (When the exhaust gas temperature rises to 250 ℃) 2, the operation of the back pass and then generating boiler combustion boiler operation should be stopped immediately, immediately stop sending, ID fan and turn off all the smoke and steam soot blowing air damper fire. 3, if the economizer afterburning, until the storage tank level control valve blocking off without pressure, flow rate of feed pump motor start 150t / h Sheung be cooled. 4, air preheater heating surface of the secondary combustion air preheater normal operation, normal operation of the air pre-heater holder; air preheater Jam occurs, the main drive motor and the auxiliary drive motor trip, contact maintenance manual plate moving continuous air preheater rotor. Soot blowing steam into air preheater for extinguishing, into the air preheater for fire extinguishing can not be extinguished. 5, the economizer outlet water temperature close to the inlet temperature (at the economizer secondary combustion), the air preheater inlet gas temperature, exhaust gas temperature, the hot air temperature is lowered to less 80 ℃, each one hole, and the hole is no longer Mars smoke and soot blowing steam stops coming out after water or fire. Open hole inspection manhole and inspection to confirm the secondary combustion goes out, after the flue vent door open to drain water inside the smoke flue opening for ventilation air damper. 6, to be re-combustion is resolved, the flue temperature does not rise and fall when stabilized, before slow regulation of the air, smoke baffle, the necessary air cooling and purging.

Future environment of new energy industries have competed in the development of new energy, new energy to seize the initiative. The same industry, too. Straw-efficiency boilers in experience and practice to promote new rural energy development and utilization of clean. It is understood that the development of efficient direct combustion of straw bale boiler heating system, was listed as the province's rural energy project focused on the promotion of clean development and utilization mode, promote the use in the province. Since the winter of 2013, a new residential community Zhoukou municipal primary pilot new energy boilers were successful. Currently, the city hundred units of straw bale demonstration direct-fired heating boiler efficiency promotion is moving forward steadily. The company has passed ISO9001; 2000 quality system certification, to provide better products for you, allowing you to buy the rest assured with ease. The company's main products are vertical steam boilers, horizontal steam boiler, WNS type of fuel (gas) steam boilers, KS-Q gas water boiler, gas wns hot water boiler, coal-fired hot water boilers, coal-fired steam boilers, coal-fired thermal conductivity oil furnace, hot water boilers and other fuel products. High standard, high-tech, high starting point, low-cost rapid rise of the company is a magic weapon. Excellent quality, integrity and service is the company to open up a vast market development tool.

Other Products