Wns Horizontal Gas Steam Boiler


Wns Horizontal Gas Steam Boiler

A strict boiler installation access. For newly installed boiler strictly enforce provincial and municipal environmental policy, a full cessation of 35 tons and below, installation and construction of coal-fired boilers to inform, installation supervision, inspection and use of registration, to cooperate with the elimination (dismantling) work.

Second, the coal-fired boiler using a registration certificate cancellation notice. According to regulations, the original registration for the 83 and 10-ton coal-fired boilers using the write-off registration certificate shall be published on the government website, while informing the inspection unit will not be tested.

Third, strengthen supervision and law enforcement boiler safety, to promote the phase-out of coal-fired boilers. The boiler safety supervision and law enforcement with prevention and control of air pollution combine to crack down on illegal installation of boilers, illegal use, not extended inspection, not extended rectification risks and other illegal acts, to perform their duties according to law, to promote the phase-out of coal-fired boilers smoothly. This year we have gone through all kinds of boilers 117 units, of the 10 units are still using coal-fired boiler inspection found, ordered to stop using and timely communicated to the relevant environmental authorities and the town street, cooperate with the 10 coal-fired the dismantling of the boiler.

Steam boiler wns horizontal steam boiler price Price: works steam boiler is heated in the drum and water is converted into steam, fire gives off heat in the furnace. Qiang boiler plumbing materials sales center is located in the southern suburbs of Datong City, is a design, sales, installation and service of integrated modern enterprise management. The main environmental operating boiler, a steam boiler fired boiler, a heating furnace, steel radiators, cast iron radiators, canned motor pump, the pump piping, air-conditioning water, galvanized pipe, PP board tanks. Details can be found! Works (in Pulverized example) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (excluding the DC furnace), into the separated saturated steam superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 1, the working principle (as an example in pulverized coal fired boilers) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (except for the DC furnace ), the separated saturated steam enters the superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 2. Pulverized coal boiler operation, the position of the center of the flame will affect evaporation. Generally, low center of the flame will lead to greater evaporation, and the high center of the flame will lead to slow evaporation. Also affects the position of the center of the flame superheated steam or reheat steam temperature. Typically, superheated steam, in particular the reheat steam temperature in the lower center of the flame, and vice versa. 3. Pulverized Coal Burner front and rear walls is arranged a thrust manner, tangential firing mode, bis tangential firing methods, each method has its own characteristics. Since the above-described arrangement can not be applied in the same furnace at the same time, the influence of steam can not be directly determined.

On the boiler industry development status of primary industrial furnace advanced level of China's unit energy consumption indicators have been close to or above the average level of advanced countries, but advanced and lagging indicators from larger, indicating that China's industrial furnace large energy saving potential. Expand the saving job is not a negative power supply of cut, but take advantage of the power potential, with minimal power consumption to maximize the economic benefits of skills. Two primary content of energy saving operation, including direct and immediate saving, energy is directly proceeds through the furnace power utilization, decreased product cost, thereby reducing the power consumption; direct energy cost of raw materials is lowered by, reducing the rejection rate, longer equipment life and other ways to save energy. Composed apparent from industrial furnace power, the power consumption in total more than 90% of the fuel consumption, the power consumption of only 7.9, the fuel energy as a heat source for various industrial furnaces is necessary. Excellent planning and proper operation of furnaces and furnace fuel compared with the same skill can get higher economic efficiency in thermal performance. Some furnace fuel saving measures, such as improving production management and operation method, the choice of light or ultra-lightweight refractory lining, the furnace proceeds sealing properties, improved incineration furnace construction and reasonable means disposed (electric furnace is a heating element) and the like, the same also applies to the energy requirements of industrial furnace electric furnace. Accompanied by vigorous development of our national economy, industrial boiler manufacturing industry in recent years has made considerable progress. Its outstanding performance, the professional standards increasingly standard, skill level and gradually move forward, continue to add product variety, economic planning significant expansion. However, during the occupation carried out in a high-speed, also paid a lot of resources and environmental values. As China's requirements for safety, energy conservation and environmental protection forward year after year, such as occupational health and safety in promoting the steady development, ensuring the safe operation of the industrial coal-fired boilers situation, to further accelerate the expansion of energy-saving and emission reduction work has become a professional industrial boilers future development of new issues and serious challenge faced. Our vertical boiler manufacturing industry has experienced decades of conduct, in particular to promote the reform and opening up drive onto the fast-track career carried out. Due to increasing demand for shopping malls, the number of production enterprises quickly add, career planning continues to expand, the boiler can supply a variety of different pressure levels and capacity, satisfaction of the needs of the current mall. Throughout the occupation to carry out industrial boiler, although impressive, but still hidden. First, the overall occupational skill level needs to move forward. The status and importance of industrial coal-fired boilers in the national economy and society for the well known. But with the current situation of high nationwide emissions corresponding proportion of the whole career of the great amount of power consumed, the soot, sulfur dioxide, carbon dioxide, oxides emissions accounted for, not only will now energy-efficient professional industrial coal-fired boilers, and construction of environmental indicators policy of resource-saving and environment-friendly society have a greater distance, and fully explain the huge energy saving potential career. Energy conservation is a worldwide problem, but also pay attention to the topic with the world. Shandong wns horizontal steam boilers due to the large number of coal-fired boiler flue gas waste dust occur during use, it has a negative impact on the environment around the city to accelerate the transformation of governance and low efficiency and high pollution boiler equipment footsteps, to control the use of polluting fuels and other measures mainly summarized the choice of strict laws and regulation, as well as payment of the corresponding grant funds to accelerate the phase-out of these updates and boilers. The view from the future to carry out energy conservation is imperative to carry out the professional boiler, boiler practitioners and new power boiler companies will become the great collective benefit of the rectification plan, in order to stabilize the mall business, we must strengthen the new product R & D efforts, together with the skills level of products to add economic efficiency, promote vocational enterprise steady development. Now carry out the bottlenecks faced by the boiler career to focus on cause-related employees, forward boiler quality, enhance environmental performance, identify corrective path in line with China's national conditions, it has become an urgent important matter.

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.

Other Products