Oil Fired Steam Boiler For Wine Making Industry


Oil Fired Steam Boiler For Wine Making Industry

Oriental Hawaii Holiday Hotel is located in Xiaogan City of Hubei Province in accordance with international five-star hotel standard design, set business rooms, SPA bath, foot care, indoor spa and other facilities in one of the hotel. Hot water boiler is one of the important facilities normal operation can not be separated. With the pace of Hubei Province in response to the national defense of the blue sky, the use of clean fuels gradually increase the proportion of Oriental Hawaii hotel provides visitors to the more perfect leisure experience a sense of the original wishing more polluted coal-fired boilers to replace clean and green gas-fired boiler. After comparing several vendors boiler industry, a number of R & D results very fast square value in the field of clean fuels, entered into a collaboration with the fast boiler. Fast boiler integrally provided a 1.4MW condensing pressure hot water boiler (CWNSL1.4-95 / 70-Y.Q) according to their actual needs. Put into use, fully meet the needs of Oriental Hawaii Holiday Hotel heating and hot water supply.

Henan oil-fired boiler Introduction Product Introduction: Henan oil-fired boiler to run than electric heating boiler economic, easy to use than gas-fired boiler. With economic development and social progress and the improvement of people's awareness of environmental protection, coal-fired boilers due to serious pollution, moving away from sight, replaced by a new environmentally friendly digital boiler, such as electric heating boiler, oil boiler, gas boiler, electric heating boiler is more expensive, gas-fired boilers need to open a gas pipeline, then, if there is no gas pipeline, and hope boiler low operating costs, only select oil-fired boiler. Boot check: 1, various instruments, whether the instrument to confirm the adequacy of fuel tank, and the inlet valve is opened. 2, confirm the soft capacity and the water tank boiler water quality meets the requirements of the main valve is opened and boiler feed water inlet valve. 3, rotation of the oil filter to remove debris. 4, drain the remaining water in the boiler, while the opening operation of the low level alarm and chain. Features: 1, inserted within a fire retardant spoiler tube, slow speed exhaust enhance heat transfer, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. 2, furnace by computer-aided design, each of the heating surface is optimized, compact and reasonable arrangement, small boiler area, high thermal efficiency. 3, the user can set the start, shutdown time, after setting, no special duty, easy, and effort. 4, according to the boiler pressure furnace design, furnace provided with a top opening to atmosphere, the boiler is in an unpressurised state, there is no risk of explosion. 5, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, combustion heat is conducted to a large extent in water, the discharged flue gas temperature is low smoke chamber, reducing heat loss and save fuel. 6, the water level sensor water level real-time monitoring, to continuously monitor the water level is normal furnace. While controlling the temperature and replenishment level sensor solenoid valves, the boiler water may be continuously supplied. 7, water boiler fuel water speed, water volume, widely used in factories, hospitals, schools, etc. required a large amount of boiling water units. Shutdown procedure: 1, when it is desired to deactivate the combustion boiler to the switch in the OFF position, the oil supply is stopped, the flame is extinguished, but the fan is still operating to blow away the residual flue gas in the furnace. 2, when the blower is stopped, the operation OFF switch to turn off the power and then, after closing the steam valve, and the fuel supply valve to close the valve. 3, open the drain valve when the discharge pressure is reduced after the boiler play an open valve, to drain the water in the boiler, and the steam partial open the drain valve to drain the water in the drum segregation. Daily checks: 1, check the water level regulator function: whether the automatic water pump stops. 2. Check flame monitoring. 3, is rotated, the slide cam portion lubricating, and wiping. 4, the flushing water level gauge 1-2 times (class), according to the proper operation, so that until the rinse water level gauge. 5, sewerage 1-2 times (class).

Tail secondary combustion flue how to deal with the phenomenon of a sharp increase in rear of the boiler flue secondary combustion flue temperature location and later. 2, the furnace, the flue abrupt change in negative pressure, flue gas is not tight at the smoke, the Mars. 3, air preheater large current swing bearing housing temperature, severe Jam occurs. 4, air preheater fire alarm issue. 5, steam temperature, economizer outlet water temperature, the air temperature rises abnormally. 6, induced draft fan vanes automatically open a large, Fan current rise. 7, as the combustion side, both sides of the smoke temperature difference increases. Reason 1, through the coarse fine grinding coal, coal poor uniformity, improper adjustment of combustion, combustion of fuel is insufficient, serious mechanical incomplete combustion, and high levels of combustible ash accumulated in the back pass. 2, an oil burner or an oil poor atomization, so that unburned droplets deposited in the flue. 3, prolonged low load operation of boiler, the furnace temperature is too low or too small amount of excess air resulting in incomplete combustion of coal or oil accumulated in the tail. 4, after the shutdown of the fuel leakage into the furnace and accumulates or after shutdown and to insufficient MFT furnace purge unburnt coal or oil accumulation at the end of the tail. 5, soot blower failure, long-term put into operation is not normal. 1 process, when a slight secondary combustion, exhaust gas temperature does not rise within 20 ℃ normal smoking temperature should be checked immediately paragraphs, the combustion site and judge whether the secondary steam soot blowing. (When the exhaust gas temperature rises to 250 ℃) 2, the operation of the back pass and then generating boiler combustion boiler operation should be stopped immediately, immediately stop sending, ID fan and turn off all the smoke and steam soot blowing air damper fire. 3, if the economizer afterburning, until the storage tank level control valve blocking off without pressure, flow rate of feed pump motor start 150t / h Sheung be cooled. 4, air preheater heating surface of the secondary combustion air preheater normal operation, normal operation of the air pre-heater holder; air preheater Jam occurs, the main drive motor and the auxiliary drive motor trip, contact maintenance manual plate moving continuous air preheater rotor. Soot blowing steam into air preheater for extinguishing, into the air preheater for fire extinguishing can not be extinguished. 5, the economizer outlet water temperature close to the inlet temperature (at the economizer secondary combustion), the air preheater inlet gas temperature, exhaust gas temperature, the hot air temperature is lowered to less 80 ℃, each one hole, and the hole is no longer Mars smoke and soot blowing steam stops coming out after water or fire. Open hole inspection manhole and inspection to confirm the secondary combustion goes out, after the flue vent door open to drain water inside the smoke flue opening for ventilation air damper. 6, to be re-combustion is resolved, the flue temperature does not rise and fall when stabilized, before slow regulation of the air, smoke baffle, the necessary air cooling and purging.

Steam boiler pressure gauge should pay attention to matters 1, rated steam pressure less than 2.45MPa fired steam boiler for wine making industry and pressure gauge accuracy not only in 2.5; rated pressure steam boiler child or equal to 2.45MPa, the pressure is too spread made not less than 1.5 level. Dial gauge diameter of not less than 100mm, in order to ensure the operation of the operator to see the surface of the pressure value shown. 2, should draw the red line on the dial gauge steam boiler, he pointed out that the maximum allowable working pressure. 3, the steam boiler pressure gauge should be provided at a convenient place to observe and purging, and to prevent the high temperature affected, freezing and vibration. 4, steam boiler pressure gauge should check at least every six months once the check should seal. 5, the pressure gauge connection tube steam boiler should leaks steam leakage phenomenon, otherwise it will reduce the pressure instruction value. 6, a steam boiler gauge scale element should be compatible with the measured working pressure, working pressure, typically 1.5; 3 times, preferably 2 times. When no steam boiler gauges, pressure gauges or pressure damage did not meet the requirements of the apparatus, boiler steam pressure gauges of the following circumstances, should stop using: 1, the surface glass breaking or blurred dial scale; 2, no seals , damage or seal verification period exceeded; 3, no pressure gauge pointer finite bit staple staple can not be restored to the limit at infinite set of bits from zero gauge pressure exceeds the pressure data bits garment allowable difference?; 4, the jump table or a pointer leak; 5, other effects gauge accurate defect. The use of the accumulator: the accumulator for a hydraulic accumulator system intermittent mechanical, hydraulic fluid may be stored in the actuator output when a batch or a low speed, and the actuator requires a large flow of fast-moving, as an auxiliary energy providing oil to the system together with the hydraulic pump, oil pump and thereby achieve miniaturization of the entire hydraulic system, to achieve the object of absorbing the impact energy sudden change fast opening and closing valve and the hydraulic load, the system generates a pressure shock, pet cause vibrations and noise, and even damage the machine. The accumulator can be alleviated, which absorb fluid shock absorber pressure pulsation absorbing accumulator, and reducing the pressure pulsation and flow pulsations of various pump, thereby reducing system noise and vibration. Having a damping effect of the gas spring accumulator, it can be used to absorb the mechanical vibrations between the body and the traveling wheel of the vehicle and the like. The accumulator can be balanced upright actuator (hydraulic cylinder) and gravity load decreases when the potential absorption into hydraulic energy store, while generating the rate-limiting resistance; upright when the actuator rises, releasing the original absorbing energy accumulator , together with the pump oil to the hydraulic cylinder, in order to achieve balance and energy.

Other Products