Oil Fired Steam Boiler Company In Jordan


Oil Fired Steam Boiler Company In Jordan

Oil-fired boiler maintenance methods "" A lot of companies because after the purchase of oil-fired boilers, Careless maintenance process, with the result that the useful life of oil-fired boiler is greatly reduced. So how should it be maintenance of the oil-fired boiler? The following article gives you a detailed analysis. After conducting oil furnace shut until the furnace cooled water to the boiler water below 70 ℃ exhausted, the internal completely remove the dirt, washed away, all manholes, hand holes, valves and other pipeline tight blockade, and with a blind plate and running boiler completely isolated. After all of the alkaline solution is added, and then injected into the soft water boiler, until the water coming out from the highest point till the boiler, the water supply valve is closed, note that the average mixing an alkaline solution inside the boiler. Stop oil-fired boiler more than a month, maintenance of law should be dry, wet maintenance shutdown method can be used the following month. To schedule the maintenance period Microflame oven, schedule the water cycle, the concentration of the alkaline solution throughout the same. Every five tests also take a basic solution, such as alkalinity less than 5-12mmol / 1 solution should be applied. Periodic inspection outage before the oil-fired boiler furnace, should be prepared to work the following three aspects: (1) review the registration technical dossier furnace boiler and boiler furnace usage understand. In order to fuel the transformation within the furnace boiler external inspection be aware, the general need to understand: the transformation of the electric furnace boiler design, manufacture, installation; boiler furnace revamping; boiler furnace use history and usage; boiler furnace water treatment case ; boiler performance and other rules and regulations. (2) Check before shutdown preparation. First, with the production schedule maintenance shutdown date, and then let the transformation of the normal furnace boiler shutdown program shutdown, but slowly disheartened. Injecting cooling method may be employed downcast water, replacing the water cooled furnace and the furnace into line ventilation cooling. When the boiler water temperature was reduced to 70 ~ 80 ℃, before drainage. Open all doors hole. When the door opened, to prevent warm water, steam jet man suddenly burns. Corresponding to the passage blocked pipe on the transformation test furnace boiler steam, water supply, sewage and other pipes and other run in the transformation of the electric furnace boiler. Blocked with shutter have sufficient strength to avoid being broken drum high pressure medium. To clear the blocking position is indicated. And other operational boiler furnace flue should be communicated reliably cut off. Also to clear the transformation of furnace soot and scale boiler by warm surface. (3) test preparation tools and lighting. In order to ensure the smooth entry inspection, the inspector should prepare the necessary equipment, tools, measuring tools and safe and reliable lighting devices.

To do a solid job Huoqiu County 35 tons of steam per hour and less industrial coal-fired boilers as well as glass, ceramics industry, coal-fired kilns clean energy alternatives work, according to "Anhui atmosphere to do on the issuance of <35 hour Anhui cities and built-up areas tons of steam coal-fired boilers and the following industry and glass, ceramic industry, coal-fired kilns clean energy alternative implementation of the program "notice" (Anhui atmosphere do [2018] No. 11), "Lu'an office atmosphere on the issuance of

A scoping

1, in the present embodiment "industrial coal-fired boilers" refers to coal as the fuel, steam or hot water for industrial enterprises, primarily to meet the production process, the power (accounting for 50% or more) and the like required for the boiler, free professional heating companies coal-fired boilers.

2, in this embodiment, "glass, ceramic industry, coal-fired kiln" refers to coal as the fuel, comprising a direct-fired coal preparation or coal as a raw material gas-segment, two-stage gas furnace, firing, heating the finished product facility.

3, the program of "built-up area" means Huoqiu county area (county towns and the former North Industrial Park), Anhui Huoqiu Economic Development Zone, excluding the township.

4, in this embodiment, "clean energy" refers to electricity, natural gas, coal gas clean large, clean oil (alcohol) and all other non-renewable energy sources of renewable energy.

Check the work before the start fuel gas-fired boiler in order to protect the safe operation of the gas boiler, improve operational efficiency boiler, make sure to check the work before the boiler starts, every detail can not be ignored. 1, check the safety accessories, thermal instrumentation, electrical instrument should be intact; 2, check the connections, whether the water leakage and the furnace body line; 3, check the waste line, the water line, return line should be smooth; 4 , should check the line voltage is 380V, the fluctuation should be within ± 5%; 5, oil-fired boiler and a filter pump check whether normal oil, gas boiler check the gas pressure is normal, not too high or too low, the oil supply opening valves; 6, check whether the pump Sheung Shui, or opening the purge valve, until the Sheung Shui so far. Water Supply System opens each valve (including the water pump and water valve before and after the boiler); 7, check level gauge, the water level should be in the normal position, to prevent false water level, if the water can be manually Sheung; 8, check the pressure conduit the valve must be opened, the wind deflector must all flue opening; 9, each knob inspection control cabinet are in their normal position; 10, a check valve should be fired steam boiler company in jordan in a closed state, the hot water boiler circulating pump valves should be closed state; 11, check water softening equipment is operating correctly, create a variety of indicators of soft water meets national standards. Carefully do the above inspection, the basic conditions for the fuel gas boiler safe and economic operation.

Application of electric fired steam boiler company in jordan steam boiler in the electrical industry applications in various industries ironing washing industry: dry-cleaning machine, dryer, washing machine, dryer, ironing machine, iron, and other equipment for use. Food Machinery Industry: supporting tofu machine, steamer, pot sterilization, packaging machines, coating equipment, sealing machine, and other equipment to use. Supporting the use of fermentation tank, reactor, sandwich pot, mixer, emulsifier and other equipment: bio-chemical industry. Other industries :( oil, automobile) steam cleaning industry (hotels, dormitories, schools, mixing station) hot water supply, (bridges, railways) concrete curing, (casual beauty club) sauna, hot swap equipment.

Other Products