Natural Gas Steam Boilers Price


Natural Gas Steam Boilers Price

For the 2018-2019 autumn-winter air pollution prevention and control work, Jinhua City, Zhejiang Province issued a public draft, mainly in the autumn and winter to reduce heavy pollution weather Development frequency.

Take measures to reduce coal comprehensive, non-electric focused on reducing the total coal consumption, in 2018 the city's total coal consumption reduction of 1% compared with 2015. New non-owned coal-fired units, the implementation of new large-scale coal-fired units and coal consumption of the same amount of capacity reduction or substitution, elimination of energy consumption, water consumption, environmental protection and safety is not up to 300,000 kilowatts coal-fired units. Development of industrial parks "One District One heat source" action plan, and more than 300,000 kilowatts coal-fired units were heating transformation, promote backward and shutting down small coal-fired thermoelectric integration of coal-fired boilers in the range of 15 km radius of the heat. Optimize the use of natural gas structure, in principle, to new natural gas cogeneration and gas chemical projects, to the new "coal to gas" projects, should adhere to increase coal gas reduction synchronized to gas will change, the premise of the gas supply contract signed and orderly implementation.

Coal-fired boiler (with tea furnace, operating a stove, grain storage and drying equipment, coal-fired facilities) carried out an intensive investigation to ensure that no dead ends, no blind spot. Investigation and the coal-fired boilers to register one by one.

According to the law to increase the city's efforts to phase out coal-fired boilers in accordance with regulations. Before the end of December 2018, the city basically out of 10 tons of steam per hour of coal-fired boiler, built-up areas out of 35 tons of steam per hour coal-fired boilers. Complete 1 set (Yiwu) per hour, 40 tons of steam coal-fired boilers transformation of ultra-low emissions, coal-fired plants to achieve ultra-low emission levels.

In principle, the boiler NOx emission is not higher than 50 mg / m, and comply with appropriate safety boiler specification. New installation and reconstruction of gas-fired simultaneously supporting the low NOx combustion device.

Biomass boilers to carry out a comprehensive investigation, complete control of boiler scale, distribution, fuel, furnace, pollution control facilities and pollutant emissions, and establish a list of management accounting. Yan Gesheng biomass boiler registration, strictly control the new urban area of ​​biomass boilers. Biomass boilers should be dedicated boiler, coal and other prohibited blended with other fuels, efficient dust bags and other ancillary facilities. Actively promote the urban area of ​​biomass boilers ultra-low emissions transformation. For existing biomass boilers, environmental inspection carried out one by one, there are multiple distributed biomass boilers, the implementation of the demolition of small and large industrial agglomeration area.

Energy-saving measures and methods of industrial boilers which industrial boiler energy-saving measures and methods which 1, to increase the capacity and improve the thermal efficiency of boilers and inefficient small compared to the large-capacity high-efficiency industrial boilers, can greatly improve the utilization of energy rate, so as to obtain greater economic benefits. Meanwhile, the cogeneration project enables conversion of exhaust or extraction steam turbine for heating, not only can reduce the loss of turbine exhaust steam, but also help to save coal resources. Industrial boiler thermal efficiency of China's low is a fact that can not be ignored, usually operating efficiency even lower. Therefore, improving the efficiency of industrial furnace hot pot, is crucial for energy savings. In one aspect, by improving the quality of the insulating material, thicker insulation, heat loss can be reduced. On the other hand, the use of secondary air system, can facilitate a more complete combustion of fuel, the effect is very significant. 2, the heating surface to reduce coking and fouling of industrial boiler during running, prone to coking, fouling phenomenon, resulting in increased and then decreased local resistance to the flow cross section. Not only conducive to smoke, but also so that heat transfer is reduced, further increasing the temperature of the flue gas. Industrial boilers and cleaning agent has a good cleaning effect, can be put in the appropriate amount sublimation decompose at high temperatures, with the heating surface of the coke, slag and contacts a chemical reaction can be automatically off after decomposition. Meanwhile, a method of periodically purging is also more effective in the early formation of fouling was loose state can be cleared periodically sootblowing. If the attachment is too long time, will translate into close like fouling, thus increasing the difficulty of cleaning up. 3, to ensure the quality of coal and industrial coal-fired boilers with coal is crucial, its moisture, volatile content factor for the speed of fire, as well as affecting the combustion temperature is extremely obvious. Maintain proper moisture content can be reduced with reduced leakage occurrence of coal and fly ash, coal seam and helps enhance the evacuation ventilation. If the moisture content is too high, will affect the speed and the temperature in the furnace, heat loss will be increased exhaust smoke. Industrial water boiler heating surface for scaling impact of large scale for each additional 1mm, the overall thermal efficiency of the boiler will be reduced by 3%. 4, many factors affect the lower exhaust gas temperature industrial boiler flue gas temperature, within the course of the economizer scale, cleaning up soot neglect of smoke in the furnace wall channeling smoke, poor treatment effect, can cause elevated exhaust temperature. On the one hand, to deal with the heating surface appears slagging, fouling and scale phenomena take timely measures to eliminate, minimize or avoid their presence. On the other hand, on the rear of the boiler heating surface is improved or increased. Industrial boiler flue gas temperature, objectively reflects the utilization of exhaust heat. But not as low as possible, the exhaust gas temperature is too low but not conducive to the normal operation of the boiler.

The following are the nine safety devices gas steam boilers price. 1, water level monitoring: the original four water level is detected on the basis of a new fifth level detection, water level in cooperation with electronic detection devices, more comprehensive monitoring of boiler water level. 2, set the time: the user can set the starting time required to stop the boiler, free combination, convenient and flexible. 3, leakage protection: when the control system detects leakage electric heating elements, will automatically cut off power to prevent leakage fault occurs. 4, water protection: When the boiler water promptly cut off the gas burner control circuit to prevent the occurrence of dry damage the burner, while the controller sends water alarm indication. 5, power anomalies protection: Upon detection of a power failure, the boiler will stop running immediately. 6, the interlock overpressure protection: When the boiler pressure exceeds the user set value, the burner operation is prohibited and the alarm. 7, pressure controller, water level alarm, safety valve, low water level alarm and other multiple security. 8, a complete gas valve and protection system: providing a gas valve and accessories from whole filter, regulator and solenoid valve, ensuring safety gas. 9, real-time monitoring of flue gas: exhaust gas temperature of the boiler can be automatically monitored more easily grasp the combustion boiler.

The design of the boiler room fire interval is how much? Section 13.1.1 boiler fire hazard classification and fire rating should meet the following requirements: a room, boiler production plant belongs to class D, to the steam boilers price rated evaporation 4t / h, when the hot water boiler rated output is greater than 2.8MW, boiler room building fire resistance rating of not less than two; steam boiler equal to or less than the rated evaporation 4t / h, when the hot water boiler is equal to or less than the rated output 2.8MW, between the boiler building fire resistance rating of not less than three; II. when the inter-tank, and a pump room between the oil heater are class C production plant, its construction fire resistance rating of not less than two, disposed within said room between the auxiliary boiler room, a room should be set apart from other firewall; III. between the gas regulator production plant belonging to Group a, which is not less than two building fire rating, should be provided between the boiler room and the immediate neighborhood regulator firewall spaced boiler room, which doors open outwards and should not be passed directly the boiler room, the ground should not spark floor. Referring again to the provisions of Article 5.2.2 GB50016-2006 "architectural design code for fire protection," according to fire resistance rating.