Industry Gas Hot Water Pipe Boiler Price


Industry Gas Hot Water Pipe Boiler Price

Tail secondary combustion flue how to deal with the phenomenon of a sharp increase in rear of the industry hot water pipe boiler price flue secondary combustion flue temperature location and later. 2, the furnace, the flue abrupt change in negative pressure, flue gas is not tight at the smoke, the Mars. 3, air preheater large current swing bearing housing temperature, severe Jam occurs. 4, air preheater fire alarm issue. 5, steam temperature, economizer outlet water temperature, the air temperature rises abnormally. 6, induced draft fan vanes automatically open a large, Fan current rise. 7, as the combustion side, both sides of the smoke temperature difference increases. Reason 1, through the coarse fine grinding coal, coal poor uniformity, improper adjustment of combustion, combustion of fuel is insufficient, serious mechanical incomplete combustion, and high levels of combustible ash accumulated in the back pass. 2, an oil burner or an oil poor atomization, so that unburned droplets deposited in the flue. 3, prolonged low load operation of boiler, the furnace temperature is too low or too small amount of excess air resulting in incomplete combustion of coal or oil accumulated in the tail. 4, after the shutdown of the fuel leakage into the furnace and accumulates or after shutdown and to insufficient MFT furnace purge unburnt coal or oil accumulation at the end of the tail. 5, soot blower failure, long-term put into operation is not normal. 1 process, when a slight secondary combustion, exhaust gas temperature does not rise within 20 ℃ normal smoking temperature should be checked immediately paragraphs, the combustion site and judge whether the secondary steam soot blowing. (When the exhaust gas temperature rises to 250 ℃) 2, the operation of the back pass and then generating boiler combustion boiler operation should be stopped immediately, immediately stop sending, ID fan and turn off all the smoke and steam soot blowing air damper fire. 3, if the economizer afterburning, until the storage tank level control valve blocking off without pressure, flow rate of feed pump motor start 150t / h Sheung be cooled. 4, air preheater heating surface of the secondary combustion air preheater normal operation, normal operation of the air pre-heater holder; air preheater Jam occurs, the main drive motor and the auxiliary drive motor trip, contact maintenance manual plate moving continuous air preheater rotor. Soot blowing steam into air preheater for extinguishing, into the air preheater for fire extinguishing can not be extinguished. 5, the economizer outlet water temperature close to the inlet temperature (at the economizer secondary combustion), the air preheater inlet gas temperature, exhaust gas temperature, the hot air temperature is lowered to less 80 ℃, each one hole, and the hole is no longer Mars smoke and soot blowing steam stops coming out after water or fire. Open hole inspection manhole and inspection to confirm the secondary combustion goes out, after the flue vent door open to drain water inside the smoke flue opening for ventilation air damper. 6, to be re-combustion is resolved, the flue temperature does not rise and fall when stabilized, before slow regulation of the air, smoke baffle, the necessary air cooling and purging.

Gas industry hot water pipe boiler price shutdown normal shutdown process step is one step in the process of boiler operation is essential to understand the shutdown processing methods to ensure more long-term operating life of boiler. When the boiler the following faults can temporarily shutdown for maintenance. Expansion port, leakage rivet joints; tube, the waterwall tubes, damage to the heating surface tube leakage; drum in contact with the flue gas, set top box, a heat insulating material off the downcomer; water supply system, a combustion system, the occurrence of breakage safety accessories . Shutdown of the gas boiler normal (full shutdown, maintenance shutdown) Step 1, in order to stop the burner, for closing the valve. At the same time feed water to the boiler, 2cm above the normal water level reaches the stop water supply, reduce the pressure. 2, close the main steam valve, open the traps, steam boiler, water cut off. 3, the electric boiler feed water control valve closed and the manual valve, boiler feed water cut. 4, steam pressure may be lowered to the water supply and drainage operations alternately 0, the pot water temperature is gradually lowered. When the temperature dropped to 50 ℃ (not hot when hand potshell head with or touch), the entire pot of water may be drained. Should be preceded by opening the drain valve or air valve above the boiler, this time into the furnace maintenance, shutdown must be kept slow cooling, rapid cooling is prohibited. From the shutdown to be able to enter the furnace maintenance, cooling time is not less than 24 hours. 5, sales of more than 24 shutdown, to total gas supply valve is closed, opens the gas pipe to completely drain the subjective dispensing gas.

Daily maintenance of gas-fired industry hot water pipe boiler priceDuring operation, the gas-fired boiler should pay attention to the following points: (1) the gas-fired boiler does not allow positive pressure combustion or smoke injection in the furnace because it is easy to burn out the coal hole cover. (2) the bottom floor plane of the gas-fired boiler shall not be watered up in order to prevent damp corrosion. The gas-fired boiler shall be inspected every 2 weeks and every 3 months after the operation of the gas-fired boiler. (1) the gas-fired boiler shall be inspected and repaired in an all-round way after the operation of the gas-fired boiler every 3 months. (1) the gas-fired boiler shall be inspected inside and outside the boiler. If the pressed part of the weld, steel plate inside and outside corrosion phenomenon, if found in serious defects should be repaired in time, if the defects are not serious, the next time the furnace shut down repair, if found When suspicious, but does not affect the safety of production, records shall be made for future reference. (2) after inspection, boiler primer may be applied on the surface to prevent corrosion. 4. Gas-fired boilers and boiler base shall be painted at least once a year. 5, There are dry and wet methods for the maintenance of gas-fired boilers: dry method and wet method. Dry maintenance method should be adopted when the boiler is shut down for more than one month. (1) dry maintenance method: after boiler shut-down, the boiler can remove the water from the furnace, and the method of dry maintenance shall be adopted under one month. (1) dry maintenance method: after the boiler has shut down the furnace, Thoroughly remove the internal dirt, rinse clean, dry the furnace with a slight fire (be careful not to fire), and then apply a 10-30 mm diameter lump of quicklime. The plates are arranged and placed in the pan, without contact with the metal. The weight of quicklime is calculated at the volume of 8 kilograms per cubic metre of the drum, and then all manholes, hand-holes, pipe valves are closed and checked every three months. If the quicklime is broken, it needs to be replaced immediately. When the boiler is re-running, the quick lime and the tray shall be removed. (2) Wet maintenance method: after the boiler has stopped the furnace, the boiler shall discharge the furnace water, thoroughly remove the internal dirt, rinse it clean, and reinject the treated water until it is fully filled. Heat the furnace water to 100 ℃, let the gas from the water out of the furnace, and then close all the valves, where the climate is cold, do not adopt moisturizing method, so as to avoid the furnace water Icing damaged the boiler.

Second Session of the CPPCC National Committee Session of March 5 press conference held in the afternoon, the CPPCC National Committee of Population, Resources and Environment Committee, Democratic National Construction Association Central Committee, Environmental Management Division of the Ministry of Ecology Environment Atmospheric Liu Bingjiang said: Last year, resolve more than 30 million tons of steel production capacity, 810 million kilowatts of coal-fired units basically reached the national emission levels of natural gas, built the world's largest clean coal power base, out of 1.3 million units in industrial furnaces, coal accounts for the country's primary energy consumption the proportion of first time below the 60% to 59%, and turned off the small coal-fired industry hot water pipe boiler prices 23000 units.

At present the country has completed a preliminary air pollution control goals, the future will continue to promote coal-fired boilers governance, and the introduction of more stringent emission performance standards of air pollution.