High Efficiency 10 Ton Oil Steam Boiler


High Efficiency 10 Ton Oil Steam Boiler

From March 18 to start, Lujiang County, Anhui Province north of the Market Authority on the area of ​​internal security to carry out a special inspection of boiler pressure boiler; To ensure the safe operation of this special equipment, complete elimination of security risks.

The inspection mainly troubleshoot and eliminate hidden dangers in the management and operation of the boiler links exist, focus on examination of whether to establish safety management systems and procedures; whether to set security management or part-time security management staffing; whether workers with valid work certificate for employment; boiler operating records, inspection records and shift recording is complete; if the boiler for the use of registration; whether the inspection within the validity period; check valve is within the validity period, the pressure gauge whether the test within the validity period. Up to now, law enforcement officers dispatched 27 people, focus on examination of 12 times the focus of special equipment supervision units, hospitals, schools, boiler 20 times, do not meet the specified use in accordance with the boiler "Special Equipment Safety Law of People's Republic of China." requirements, issued a supervision instructions, requires immediate rectification unit, for there is no regular inspection of boilers or unqualified, shall not be put to use.

Industrial gas high efficiency 10 ton steam boiler for industrial use industrial gas steam boiler is a low-pressure gas steam boiler, but its high thermal conductivity temperature of the liquid inside, and the liquid explosive is mostly, if working in industrial gas steam boiler thrown thermally conductive fluid leak and cause a fire or even a large possibility of an explosion, which is very dangerous, so run industrial gas steam boiler safety is often worth the length of the face. Because the range of high temperatures (above 320 ℃), low voltage (0.3 to 0.5MPa), the heating temperature can be precisely controlled, it can replace the original steam boiler heating. Industrial gas steam boiler is heated up to a temperature of 350 ℃, molten salt furnace is heated up to a temperature of 530 ℃. Because the ash can not be produced by industrial combustion gas steam boiler fuel gas, if the gas and air mixture into the furnace is injected within a certain range may explode. Gas steam boiler operating temperatures above 400 ℃ oil and molten salt heat transfer medium, having a molten salt heat steam than the gas lifetime advantages, but otherwise are at a significant disadvantage, in particular the complexity of running the system.

Dry: six gas-fired boiler safety procedures (hot water + steam) stage, the purchase of gas-fired boiler more and more users, in many industries, such as oil exploration, hospital disinfection, chemical production, wine feed, and so on. But many users initial contact with a gas boiler told us how to get started quickly boiler operation is not clear. First, all personnel must be familiar with the operation of the boiler boiler performance and safety knowledge, certificates; this non-job employees Never operate. Duty personnel should strictly follow the regulations, do a good job operating records and shift recording, the security situation should shift equipment and run tests, carried out. When the shift to check the boiler is intact. Second, purchasing, installing, or before the initial operation of the boiler, the boiler and safety accessories must conduct a comprehensive inspection, inspection and determined within the validity period to start. Third, Kai furnace ready to check the gas pressure is within the normal range of values, not too high or too low; check whether normal pump Sheung Shui, if unusual you need to open the purge valve until the Sheung Shui so far. Open the door of each section Water Supply System (including Sheung Shui before and after the festival gates pumps and boilers); check the water level, the water level should be in the normal position, the water level gauge, a water color need to plug in the open position, to prevent false water level, if missing water can be manually Sheung; check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob inspection control cabinet are in their normal position; high efficiency 10 ton steam boiler check valve is in the normally closed state, heat water boiler circulating pump outlet valve should be turned off; check water softening equipment is operating correctly, soft indicators of compliance with national standards. Fourth, Kai furnace run time 1, steam boilers Open the power to start the burner; check manholes, hand holes around the flange and valve leaks will be tightened, if there is still leakage after tightening occurs, you need to immediately stop maintenance furnace; l when the air pressure 0.05 ~ 0.1MPa, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; when the pressure was raised to 0.1 ~ 0.15MPa, rinsed trap gauge; pressure was raised to 0.3 MPa, the "fire load / small fire" knob to "fire" to strengthen the combustion; 2/3 when the air pressure was raised to the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; out when the drain valve when steam is completely close it; after all drain valve closed, slowly open the main valve to open, and then half a turn; "burner control" knob to "Auto"; level adjustment: adjusting the water level (according to the load manually when to start and stop the pump), low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; steam pressure adjustment: adjusting the combustion load in accordance with (manual adjustment fire / small fire) determines combustion conditions The flame color, smoke color determination condition atomisation air quantity and exhaust gas temperature observed concentration chimney, the best change in the combustion temperature to be adjusted according to the combustion. 2, start the circulation pump hot water boiler; startup burner; 15 minutes after start, "" fire load / small fire "spin-bit color button to" fire ";." Burner control "knob to" Auto "five, normal stop 1 furnace, hot water boilers' fire load / small fire "knob to" small fire "; off the burner; close the fuel supply valve; closing dampers; boiler after the temperature dropped to 50 ℃, the pump outlet valve closing cycle ; .2 circulation pump is stopped, the position of the steam boiler "fire load / small fire"; Close combustor; steam pressure drop when the sewage to 0.05-0.1MPA; closing the main steam valve; manual replenishment to the higher level; Close valve; Close supply valve combustion; closed dampers; six off the main power, an emergency shutdown, the steam boiler main steam valve closed; off the main power; 2, boiler water boiler inlet and outlet valve closed; opening the emergency valve and the emergency discharge replenishment valve; off the main power switch; notification superiors.

Gas-fired heating is to protect human health and indoor warm natural gas boiler with natural gas, LPG, city gas and other gaseous fuels for fuel combustion in the furnace put out heat, heat the pot of water, and it vaporized into steam the thermal energy conversion device. Water pan (drum) is continuously released from the combustion of a gaseous fuel energy to heat the furnace temperature is increased and produce steam under pressure. Since the boiling point of water increases with increased pressure, the pot is sealed, the expansion of water vapor generated inside the pressure limited thermodynamic formed, strictly speaking, the high efficiency 10 ton steam boiler is heated in water at constant pressure saturated steam drum regasification water formed, is widely used as an energy source. Gas-fired heating is to protect human health and indoor warm, so the choice of natural gas boiler when security issues are important, but the quality can not be ignored, and only with good quality, just more comfortable when in use, some of the services also can do better, choice of heating is customer satisfaction. Learn natural gas boiler certainly need to know the sales of the product, and if it shows good reputation natural gas boiler in the comprehensive aspects are still very good, worthy of consumer choice, performance, and thermal energy conversion can consult, when such use was not there will be problems when installed, do not worry voltage is not enough. Gas boiler shutdown method: after stopping a powder, a duct for 5 minutes and then purged to stop the gun. Oil gun should be purged one by one, not at the same time purging multivessel oil gun. After completion of purging gun oil, natural ventilation of the boiler furnace 5 to 8 minutes, 20 ~ 30% of the air volume is not less than the rated load. To exclude combustible material remaining in the furnace. The fuel gas-fired steam boiler can be divided into natural gas, city gas steam boiler, a steam boiler coke oven gas, LPG and steam boiler; according to the structure can be divided into vertical and horizontal steam boiler steam boiler. Gas boiler shell type three return all wet back downstream pyrotechnic pipe structure, the combustion flame in the combustion chamber large positive pressure, fully extended, low combustion heat load, the high heat of combustion efficiency, effectively reducing the exhaust gas temperature, energy saving , more economical, and a waveform furnace threaded pipe structure, i.e. increase the strength of the heat absorption of the boiler, but also to meet the needs of thermal expansion of the heating surface, scientific and rational, and durable.

Other Products