Gas Steam Boiler All Categories


Gas Steam Boiler All Categories

Vertical steam boiler all categories combustion characteristics combustion grate section with double action, heating up, fast boosting of unburnt gas through the secondary combustion, functions as combustion, smoke, dust. Bending the upper furnace tube arrangement convection heating region, disposed in the lower furnace grate tubes and radiation heating furnace area, structure of the furnace and the flue gas flow, reasonable layout, good heat transfer, the boiler reasonable design, simple structure operation, easy maintenance, small footprint, less investment in infrastructure, the company is one of small enterprises with steam, heating and other equipment ideal. Gas steam boiler performance characteristics: 1, the furnace and comparing the old vertical boiler, heating area, rapid boost heating, less coal, high thermal efficiency, can save 25-30% of coal. 2, a furnace with multiple, user-friendly, the furnace can be used for the production of steam steaming canteens, disinfection tableware, bath heating, process steam, heating and the like locally heating the room. 3, the furnace with natural ventilation, induced draft fan and the blower does not need, no noise. 4, compact structure, installation, operation, easy maintenance, may be integrally handling, suitable flowability units. 5, heated with steam bath, food, heating, steaming, etc., pressure gauge scale strictly controlled within the design pressure, working pressure at any time shall not exceed the operating pressure. The scope of the steam boiler Application: can be used in textile, printing and dyeing, paper, food, rubber, plastics, chemicals, pharmaceuticals, iron and steel, metallurgy and other industrial products machining process required steam, and for enterprises, institutions, hotels, schools, restaurants, service industries such as heating, bath, air conditioning and hot water. Pledge: Since the equipment installation qualification pressure parts warranty 3 years, 12 months, auxiliary and lifetime maintenance, warranty period free of charge warranty for non-human failure (various defects caused by faulty equipment itself) of the Company, the replacement of damaged parts, the warranty period or man-made damage, is still responsible for maintenance and guidance equipment, for repair, replacement parts only fees. Quality assurance after the expiry responsible for maintenance of life.

When the external inspection of the steam boiler all categories few notes below Henan fast boiler's steam boiler Xiao Bian told you about the external examination of the few notes need to be transported when the steam boiler, it is necessary to check the external steam boiler, 1, security accessories are complete, sensitive, reliable, secure attachment of the installation for compliance with relevant regulatory requirements. 2, can test gauge when necessary, the safety valve exhaust test. 3, auxiliary equipment (fans, pumps) is functioning properly. 4, automatic control equipment, signal systems and a variety of instruments is sensitive and reliable. 5, various types of door is tight, leaks and corrosion. 6, placed in the drum to the combustion chamber wall may be observed, water wall is normal, without deformation or other anomalies. 7, the combustion is stable, whether black smoke chimney. 8, steam boiler furnace wall, architecture, platforms, escalators, etc. is intact: water treatment equipment is operating properly. 9, boiler room facilities for compliance with relevant regulatory requirements, management is normal and so on. 10, the visible parts of the boiler weld cracks cracks (joints) appears. Classification of a steam boiler combustion apparatus, the four-way steam boilers for solid fuel burner layer being layered on the furnace grate stratified charge combustion. Such as: hand-burning stove, chain furnace stoker furnace. Second, the four-way chamber burner fuel mist of fine particles with the air injected into the furnace combustion furnace in suspension. Such as: Pulverized Coal, oil furnace, gas furnace or the like. Three, four boiling furnace fuel stream is lifted carrying like rolling boil under goes a combustion furnace.

Successful ignition of fuel steam boiler all categories can not run, because of those common oil gas powered steam boiler applications, all of you should ignite the fuel steam boiler in the application process, no way ignition is also the most common problems. Fuel steam boiler in the application process, most likely resulting in no way ignition, resulting in fuel steam boiler can not run normally, small series to introduce you to a steam boiler does not ignite the fuel to run those common reason. Fuel steam boiler can not run common ignition of those reasons: First, the ignition problems: pulse ignition and control systems such as the one of which has caused the problem, the fuel steam boiler can not start. Second, the battery thing: to be very important to see if the battery is a battery in the end is not too aging. The charge is not standard, the same can not let steam boiler fuel ignition. Third, the water pressure thing: at the inlet steam boiler fuel filters block the formation of water can not flow normally through the clean up clean ok. Fourth, the pulse valve problems: If the boiler ignited fuel vapors to ignite division saw sound, no pulse valve "despair" squeak, probably for the pulse valve is damaged or degraded, pulse valve degeneration, will not manipulate, the beginning of the ignition operation when closing a flow will hit a fire, but the fire immediately and confinement; pulse valve before confirm whether there is a problem to confirm whether normal ignition actuating member, if the fault can not pull the valve actuating pulse. V. ignite feelings needles or needle thing: fuel steam boiler ignited hand shift. You can change or correct the ignition pin arrangement; if feelings of degradation promise things, as long as the feeling wiped clean arranged on it. Six, usually no way to exhaust smoke tube. Smoke tube steam boiler with a fuel block, clean breathing tube blockers smoke tube is too long, the configuration is not correct. Referring may be configured to inform two coaxial cigarette heater tube. VII vapor setter joint problems: fuel steam boilers, water vapor degradation intimal flap valve or joint damage, not the weak control push button switch; weak bad control switch button.

Recently, the Changsha City issued a notice on the transformation of low nitrogen gas boiler related documents. Details are as follows:

1, a total transformation time for two years, 2019-2020 years.

2, the transformation range: High-tech Zone, Furong District, Tianxin, Kaifu District, Yuhua District, Yuelu District administrative region, the city of hope Gaotangling Subdistrict high Tong Ling Area, Osan streets Yujia slope Area, Lake Daze in the region ban on burning streets, white sandbar streets, moon Island street, Jinshan bridge street, Golden Park street, Xingsha streets of Changsha County, Hunan Long street, Quantang streets, Langli streets, long queue streets, such as the scope of the existing town of Sha It is not less than 1 ton of steam (greater than or equal to the rated power or hot water boiler, organic heat carrier in the boiler 0.7MW) gas boiler (facility) (boiler equipment including special directory outside the range) low nitrogen unit owners embodiments transformation. Or more areas outside the area of ​​self-implementation.

3, the transformation of the standard limits: the new replacement and overall gas boiler Changsha NOx emission is less than 30mg / Nm³; gas boiler (facility) was transformed with the nitrogen oxides emission concentration of less than 50mg / m³.

4, 2019 Task: In addition to the Furong District, Yuhua District, within a range of high-pollution fuel combustion zone ban other jurisdictions to start the transformation from June 2019, 50% complete gas-fired boiler (facilities) low nitrogen transformation and complete acceptance.

5, 2020 Tasks: Before the end of October 2020 to complete all gas boilers (facilities) within the range of high-pollution fuel combustion zone ban on low-nitrogen transformation and complete acceptance.

Other Products