Gas Fired Vertical Water Boilers


Gas Fired Vertical Water Boilers

6 tons gas steam boiler steam pressure adjusting a boiler operation, must frequently monitor the pressure gauge indicated. To maintain stable steam pressure, boiler pressure must not exceed the design pressure. Second, increasing boiler load: Steam pressure decreased boiler load is increased, if the level is high at this time, the amount of water should be reduced to a water supply or suspend, the amount of coal and increase the air volume. Gradually increase the amount of water at the same time to strengthen the burning, keep the steam pressure and the water level is normal. Third, the boiler load reduction: the vapor pressure rises to reduce boiler load, if the level is high at this time, the amount of coal should be reduced and the air volume, reduced combustion. Then the appropriate water reduction or suspension of water supply to the water vapor pressure and stability in the nominal range. Then press the normal combustion and the amount of feed water 8 to adjust. If the actual water level within the boiler is low, to increase the amount of water should, until the water level returns to normal after the combustion and needs to be adjusted according to the water vapor pressure and load changes.

In recent years, the increasing popularity of Yichun City, Jiangxi Province comprehensive energy saving coal-fired boiler upgrade project, plans to eliminate 75% of the downtown 10 steam tons / hour and below the coal-fired boilers, a ban on new 20 tons of steam / hour and less fuel coal boilers; the rest of principle, then the new 10 steam tons / hour of coal-fired boilers.

Following this, Jiangxi Province Department of Finance issued a special subsidy fund boilers, Yichun downtown 2015--2016 phase-out 10 steam tons / hour coal-fired boilers companies grant. The subsidy standard is: 2 out of steam tons / hour and coal-fired boilers, subsidies to 10,000 yuan / Taiwan; out of steam 2-10 t / h coal-fired boiler, subsidies for 20,000 yuan / Taiwan.

First, when the flue temperature dropped to below 50 ℃ Solution: Check the tail may enter the flue if heated, while the flue thoroughly remove soot. No burning flue tail, can be re-started ignition; if burning, should be replaced, repaired burning member. Second, the combustion chamber when the negative pressure is too large Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1 hour and stable, open the inspection hole inspection; after inspection after confirming the fire source, before start the fan ventilation. Third, shutdown or fire, air gun valve ajar solutions: reinforcing and electric steam boiler feed water drainage, or open the valve economizer recirculation tube to protect the economizer is not burning. Fourth, Kai, during shutdown lower furnace temperature, a solution of unburned fuel in the furnace: extinguishing device immediately put into vapor, carbon dioxide or other devices off fire. Five burning improperly adjusted, with insufficient wind or with the wind unreasonable Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan. These are the methods of electric heating steam boiler fast boiler to provide you with the handling of soot in the chimney, if you use electric steam boilers, with more than five can control their own boiler equipment need to be cleared up the flue, and select the appropriate method .

Structure and characteristics of Water Tube Boiler (double Longitudinal Tube Boiler)

The structure of the double vertical tube water tube boiler is mainly composed of upper and lower vertical tube, convection tube bundle, water wall tube, header box and down tube and other pressure-receiving components. The length of the lower drum is about half shorter than that of the upper drum. The empty space is provided with a furnace, a curved water pipe is arranged between the two drums, and a water wall tube is arranged around the furnace. The burning equipment adopts a gas/oil burner, and the tail flue has an economizer. The boiler evaporation is generally less than 20 tons / hour (t / h), the working pressure is less than 2.5 MPa (MPa). The high-temperature flue gas enters the rear convection flue from the right exit of the furnace, flows in an S shape along the two smoke-proof walls, flushes the convection tube bundle laterally, and then flows through the economizer from the left side of the furnace wall, and is discharged by the induced draft fan and the chimney.