Gas Fired Steam Boiler For Hotel


Gas Fired Steam Boiler For Hotel

Gas fired steam boiler for hotel which safety devices 1, real-time monitoring water: water with electronic detection devices, real-time monitoring .2 boiler water level, time setting function: the user can be freely set in combination boiler stop time from .3, leakage protection: the control system upon detection of leakage electric heating elements will automatically cut off power .4, water protection: when the time to cut off water gas boiler burner control circuit to prevent the occurrence of dry damage the burner, while the controller sends missing .5 water alarm indicator, power protection function: gas steam boiler immediately stopped .6, overpressure interlock protection: when the boiler pressure exceeds the user set value, the burner operation is prohibited and the alarm .7, pressure controller, water level alarm, safety valve, low water level alarm and other multiple security .8, and the complete gas train protection system: to provide the filter, regulator, solenoid valves and accessories such as a complete gas train to ensure that the gas .9 safety, flue gas monitoring means can automatically monitor the exhaust gas temperature of the boiler, more easily grasp the combustion boiler.

Gas Steam Boiler Water Wall Tube Explosion Analysis and Processing With the west-east gas project in-depth and complete, and the "coal to gas," the implementation of Beijing, Urumqi, Daqing and other cities and district heating heat source to promote the use of gas-fired boiler . More commonly used gas-fired boiler type D, type 0, A-type, p-type [1-2], these four basic types of furnaces by dividing the furnace cross-sectional shape. Wherein, D, 0, A-type small capacity boilers belonging horizontal boiler, boiler Ding is a large vertical boiler. The four furnaces are used membrane wall structure, eliminating the flue gas leak, reduce heat loss and improve the thermal efficiency of the boiler, ensure the stability of the structure. A compact, short installation period, high thermal efficiency, low noise, low energy consumption, low emissions, long life (design life 30a), adaptable load fluctuations and other characteristics can be controlled by computer program running faults and Protective function. Domestic slightly less than the amount of evaporation experience in the development of high-power gas fired steam boiler for hotel in the 75t / h or more, most of the development work is based on the introduction of Europe and learn from small gas steam boiler above. China's own design of high-power gas steam boiler in the course of running more than a vibration, burst pipes and other problems. This paper discusses some evaporation of the squib causes and treatment of boiler waterwall 160t / h of a gas steam.

Wuhan Port District Social Welfare Institute (apartments for the elderly) is invested by the government pension services, with a total construction area of ​​38,000 square meters, 532 beds, mainly adopt destitute persons, social support on behalf of the elderly. Hope to provide welfare to the elderly year-round 24-hour hot water, the original boiler equipment can not meet this demand, therefore, require additional purchase orphanage hot water boiler. After much investigation, in cooperation with the welfare determined fast boiler, provides three integrally condensing gas hot water boiler (WNS1.4-1.0 / 95/70-Y.Q) by a fast boiler.

Fire boiler design pitch is much: a room, boiler production plant belongs to class D, to a fired steam boiler for hotel rated evaporation 4t / h, when the rated output is greater than 2.8MW hot water boiler, the boiler room building fire resistance rating of not less than two ; rated evaporation steam boiler is less than or equal to 4t / h, when the hot water boiler is equal to or less than the rated output 2.8MW, between the boiler building fire resistance rating of not less than three; m-inter-tank, oil pump and the oil heater are inter production plant belonging to class C, not less than two of its construction fire rating, between said room is arranged within the auxiliary boiler room, a room should be set apart from other firewall; March and gas regulator production plant belonging to Group A, which building fire rating of not less than two, should be provided between the boiler room and the immediate neighborhood regulator firewall spaced boiler room, which doors should open outwards and should not directly access to the boiler room, the ground should not be spark Ping.

Other Products