How to combine gas egypt fired steam boiler when a parallel gas steam boiler / steam boiler two or more than two runs, the new operational boiler steam supplied to the total charge of steam, the furnace is called parallel, how a natural gas steam boiler is operating analysis of: (1) steam boiler gas before the merger, should decrease the fire. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing the total cost of the user is provided drain pipe, the water shall be discharged, and then washing water level gauge, the normal water level is maintained below the water line. (2) At this time, the steam pressure gas steam boiler is reduced, when the steam pressure is below the vapor piping system pressure of about 0.05MPa, the water level can be in communication with the furnace. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. (3) a combination of steam gas boiler, a main steam valve should be opened slowly. When the main steam pipe soda no impact should open the main steam valve, to observe changes in water level. (4) Complex fire, pay attention to the steam boiler water, maintain the normal operation. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees gas steam boiler drum double lateral structure, completely overcome the bulging phenomenon boiler superheater tubes are directly exposed to the furnace caused by the heating surface is disposed more reasonable. Using membrane wall structure on both sides of the furnace, both to ensure the sealing of the furnace, but also improves the thermal efficiency of the boiler.

Steam boiler pressure gauge and hydraulic accumulator Henan fast boiler's egypt fired steam boiler introduce small series with a pressure gauge and hydraulic accumulator steam boiler pressure gauge should pay attention to: 1, rated steam pressure of less than 2.45MPa steam boiler , not only the accuracy of the pressure gauge to 2.5; rated steam pressure 2.45MPa promoter or equal to a boiler, the pressure is too spread made not less than 1.5. Dial gauge diameter of not less than 100mm, in order to ensure the operation of the operator to see the surface of the pressure value shown. 2, should draw the red line on the dial gauge steam boiler, he pointed out that the maximum allowable working pressure. 3, the steam boiler pressure gauge should be provided at a convenient place to observe and purging, and to prevent the high temperature affected, freezing and vibration. 4, steam boiler pressure gauge should check at least every six months once the check should seal. 5, the pressure gauge connection tube steam boiler should leaks steam leakage phenomenon, otherwise it will reduce the pressure instruction value. 6, a steam boiler gauge scale element should be compatible with the measured working pressure, the working pressure is usually 1.5-3 times, preferably 2 times. When no steam boiler gauges, pressure gauges or pressure damage did not meet the requirements of the apparatus, boiler steam pressure gauges of the following circumstances, should stop using: 1, the surface glass breaking or blurred dial scale; 2, no seals , damage or seal verification period exceeded; 3, no pressure gauge pointer finite bit staple staple can not be restored to the limit at infinite set of bits from zero gauge pressure exceeds the pressure data bits garment allowable difference?; 4, the jump table or a pointer leak; 5, other effects gauge accurate defect. The use of the accumulator: the accumulator for a hydraulic accumulator system intermittent mechanical, hydraulic fluid may be stored in the actuator output when a batch or a low speed, and the actuator requires a large flow of fast-moving, as an auxiliary energy providing oil to the system together with the hydraulic pump, oil pump and thereby achieve miniaturization of the entire hydraulic system, to achieve the object of absorbing the impact energy sudden change fast opening and closing valve and the hydraulic load, the system generates a pressure shock, pet cause vibrations and noise, and even damage the machine. The accumulator can be alleviated, which absorb fluid shock absorber pressure pulsation absorbing accumulator, and reducing the pressure pulsation and flow pulsations of various pump, thereby reducing system noise and vibration. Having a damping effect of the gas spring accumulator, it can be used to absorb the mechanical vibrations between the body and the traveling wheel of the vehicle and the like. The accumulator can be balanced upright actuator (hydraulic cylinder) and gravity load decreases when the potential absorption into hydraulic energy store, while generating the rate-limiting resistance; upright when the actuator rises, releasing the original absorbing energy accumulator , together with the pump oil to the hydraulic cylinder, in order to achieve balance and energy.

Temperature protection device during the fuel egypt fired steam boiler over temperature to regulate protective effect of temperature protection is an important procedure fuel steam boiler safe operation is particularly important for the regulation and protection of the boiler temperature of the fuel vapor; at the same time to regulate in the fuel steam boiler overtemperature Protective effects. Conventional boiler temperature protection means is a bimetallic temperature controller. Flame protection: prevent explosion of the furnace, steam boiler fuel flame protection means must be provided, is a function of combustion (including ignition, combustion or misfires when halfway off, typically within five seconds reignition monitoring the furnace, a second the run off into the oil (gas) solenoid valve, and turns on and audible alarm signal, when the blower continues to operate, the residual gas was purged of combustible furnace, after 20 to 30 seconds purge, automatically cut off and various auxiliary blowers supply the boiler operation stops. role is to monitor the flame signal the presence of a flame or an interrupt control apparatus mainly using a photomultiplier tube, a photovoltaic cell and photosensitive resistance, they have an infrared type or ultraviolet type a photoelectric conversion element, the working principle of the light converted to the corresponding strength of the radiation strength of current and the linear output state, sometimes weak induction current, through amplification, in order to have an effect on the controller.

Recently, the Tianjin Municipal Government issued the latest "2018 ~ 2019 autumn and winter tackling air pollution comprehensive management action plan" (the "Program"), "plan" put forward specific remediation requirements: the city's 65 steam tons / hour and above the basic realization of coal-fired boilers coal-fired power plant ultra-low emission standards, the development of energy-saving and ultra-low emissions rehabilitation programs for 65 steam tons / hour or more coal-fired boilers, the implementation started after the end of the heating season. Before the end of this year, within the city basically eliminated 35 tons of steam / h and coal-fired boilers of 25 iron and steel industrial enterprises discharge waste depths of governance, the basic completion of the iron and steel, building materials, thermal power, coking, casting and other key industries and coal-fired boiler fugitive emissions control.

"Plan" the implementation process to uphold the objectives warm winter and clean heating double standards, combined with the actual development of coal-fired boiler rehabilitation programs, to ensure completion before the end of the year 206,100 rural residents to use clean energy alternative to coal for combustion. Guidelines established after the first break, for the substitution of gas for coal to electricity instead of coal and other alternatives, in the case of gas supply, power supply is not implemented, the existing heating facilities will not be dismantled until the gas supply, power supply after the successful implementation be removed. And to develop high-pollution fuel combustion zone ban zoning adjustment programs, complete with electricity instead of coal, substitution of gas for coal in the region included the range of high-pollution fuel combustion zone ban. For failure to implement the heating area clean, good smokeless coal tender, production, supply, to ensure smokeless coal substitute the existing polluting large coal-fired boilers. Among them, before the heating period to complete large-scale centralized distribution, heating Doing the fragmented coal blending, before the end of December 2018, the actual realization of bulk coal dealers cleared.