Efficiency Nature Gas Fired Hot Water Boiler


Efficiency Nature Gas Fired Hot Water Boiler

Heard so much about fast boiler made a number of achievements in the areas of clean boiler, this time my unit and quick cooperation parties, give me your company's boiler unit is in line with the requirements of our team boiler, to achieve a clean, energy-saving, environmentally friendly way of heating . Moreover, your company for the Beijing authorities have provided more office cleaning boilers, a good reputation. So, we finally reached a cooperation. --customer feedback

What is the reason for steam boiler explosion? Boiler itself is flawed: the pressure component aging, strength weakened, or leakage, corrosion, deformation, scaling and other defects can not be timely maintenance and eliminate hidden dangers, but let the disease run with the boiler and so on. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Therefore, we must carry out regular inspection of boilers in accordance with national requirements. 3. poor management, furnace workers irresponsible or low levels, lead to misuse. Therefore, furnace workers must obtain a certificate as required. None of the above is the main reason for the actual boiler explosion. In actual operation, the most common situation is that the boiler add cold water and drying, which is very dangerous. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass efficiency nature fired hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. This is also the operators need the most important thing vigilance. There may be debris blocking the pressure cooker vent, causing the pot to continue to increase pressure, excess pressure can not be discharged to reach the pot of strength, can withstand the pressure will naturally explode, of course, does not rule out the cause of pan itself. Substandard quality, tank leaks, inadequate exhaust usually cause an explosion. Therefore, before use, carefully check the vent is smooth, not to violate the specification and taboos, without any danger.

The steam boiler can be divided into three kinds according to the fuel (electricity, oil, gas), such as electric steam boiler, oil steam boiler, gas steam boiler, etc. According to the structure can be divided into vertical steam boilers, horizontal steam boilers, small steam boilers are single, double-return vertical structure, large-scale steam boilers are mostly three-way horizontal structure. If according to the classification criteria above, there are a lot of steam boilers, take an ordinary fast-packed 4-ton steam boiler. Water is heated into steam in the drum and heat is emitted by fire in the furnace, which is the principle of the steam boiler. Steam The combustion part of a steam boiler consists of a chain grate and a drive device, together with a combustion chamber composed of a boiler rack on the grate frame. Surrounded by refractories. Coal from coal hopper, there are coal gate to control the thickness of coal seam while sealing the front of the air. The lower part of the combustion chamber is the place where the blast enters. This steam boiler has great resistance and needs forced blast. The cinder of a steam boiler, discharged from the back of the grate through Eagle's mouth iron and sent out of the furnace by a slag extractor. Steam boiler flue gas from the back of the boiler, by the steam boiler drum one-way smoke pipe forward, from the two-way smoke pipe back to the rear, then into the dust collector to separate ash, and then through the induced fan from the chimney exhaust Out. The above is the working principle of steam boiler, of course, the operation of steam boiler without other equipment, such as the induced fan not only undertake the task of exhaust flue gas, but also the steam boiler negative pressure operation necessary. There are also pressure vessels, thermometers, safety valves, pressure gauges, pumps, steam pumps, etc. All are essential for steam boiler work. Pump leak problem. The actual output flow rate of gear pump is smaller than that of theoretical flow due to the leakage of gear pump in the process of operation. The main leakage channel of gear pump is through the gap between the two sides of gear and the cover plate on both sides of the gear, which is 75% / 85% of the total leakage of the pump. Radial clearance leakage between gear top circle and inner hole of pump; clearance leakage through gear meshing. Because of the leakage of gear pump, the output pressure does not go, which affects the range of use of gear pump. In order to solve the problem of low output pressure of gear pump, the way of adding floating sleeve or elastic baffle on both sides of gear pump is adopted to reduce the leakage of gear pump and improve the output pressure of gear pump. Radial force imbalance problem. In the working process of the gear pump, the pressure on the outer circle of the gear is not equal, which results in the radial unbalance force at the shaft and bearing of the gear. This radial imbalance will accelerate the wear and tear of the bearing, reducing the bearing The service life also may cause the gear shaft to deform, causes the tooth top and the pump body inner hole friction, damages the pump body, causes the pump not to work normally. The common solution is as follows: (4) opening pressure balance slot on pump, leading high pressure oil to low pressure area, but it will increase pump leakage and affect pump volume efficiency; (2) reducing the size of the pressure chamber, reducing the pressure area acting on the gear teeth, and thus reducing the radial unbalanced force.

Spark ignition rods gas boiler, but because the misfiring spark ignition rods gas boiler misfiring but the reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; For more information about oil oil oil, information technology please pay attention to the public number of oil rings. Check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. When the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas efficiency nature fired hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change.

Other Products