Coal Or Electricity Hot Water Boiler


Coal Or Electricity Hot Water Boiler

The boundaries of the coal or electricity hot water boiler and large boilers and boiler combustion method usually used in home heating or bathing more, there is a small naturally large boilers, both of which boiler has a very clear difference, even the demarcation has many new the user does not make equipment for combustion, the following'll tell you about methods of water and fuel demarcation between the two: First, the demarcation of large and small boiler boiler boiler capacity according to the size of the boiler has a large, medium, small of points, but there is no fixed, definite boundaries between them. With the development of China's power industry, power plant boiler capacity is increasing, and the boundaries of the capacity of large and small boilers will continue to evolve, from the current situation, the generated power is equal to or greater than 300MW boiler unit configuration for large boilers. 1T is bounded by Second, the correct combustion method, the water fill, fill the tank to keep less than half tank of water. All the radiator bleed valve deflated until the water --- pay attention to add water. 2, the briquettes ignited on the gas stove, coal stove put in --- must take the good eye. 3, the pressure of coal, opening the damper. 4, Kai furnace few days to wash bleed radiators, Qin replenishment. In fact civilian life boiler boiler, its small size, low power consumption, a typical feature is suitable for home use. Two kinds of boiler From outward appearances it seems like, in order not to confuse, we have to remember their boundaries, to master the correct combustion methods help us to secure the future use.

Small series to introduce horizontal steam coal or electricity hot water boiler steam boiler arch horizontal tube plate with threaded pipe drum composition, high heat transfer efficiency, boost fast enough output, high overload capability, hard fouling smoke tube. Today, let us together look at it. Horizontal welding binding sites steam boiler using high-temperature region and large machining bundle special treatment to ensure the welding quality and service life. Flammable, widely used fuel, burn bituminous coal, anthracite coal, firewood, industrial waste, organic waste and so on. It solves the problem of tube plate crack, eliminating the dead zone at the bottom of the drum, good water cycle effect, prevent the lower drum drum kits. Horizontal steam boiler compact structure, small dimensions and saves capital investment, easy installation, tipping valves, and piping to run hydropower. Stable, easy adjustment, the unique design of air sealing, bank up a fire a long time. Times atmospheric pollutants are oxides of dust, sulfur and nitrogen contained in horizontal steam boiler flue gas, which can achieve emissions targets Protection index when a predetermined number of times to unpurified. These substances emissions control combustion pretreatment, improved combustion techniques, dust removal, desulfurization and denitration. By means of a high chimney stack can reduce the concentration of pollutants in the atmosphere of the area.

Low nitrogen coal or electricity hot water boiler revolution to lead the industry in fact so much importance to the APEC summit in nitrogen oxide emissions from the boiler is not accidental. Nitrogen oxide emissions into the atmosphere dissolved in water will generate nitric acid rain, caused extensive harm to the environment, causing huge losses to the economy. For the boiler, fuel combustion is the main part of the nitrogen oxides generated. However, in most cities, nitrogen oxide emissions from the boiler still remain at a high level, or simply just to reach deeper coal to gas demand, low nitrogen, low dust and other environmental requirements far not on the agenda.

Comparison on electric coal or electricity hot water boilers and gas boilers analysis that is both: a wide range of aspects of the early vote gas than electric boilers cheap, how much detail should be distinguished from gas boiler brand size, with or without condensate recovery and technical maturity of all determine the price of gas boiler; brand electric boiler, the applicable type, excellent technology, quality products; create two related conditions, such as plumbing, gas station; select high and low voltage electricity, create distribution and so on. If you choose gas boiler, gas pipeline itself, it does not demand an opening fee (usually about opening expenses 100 000), if the price of natural gas at a relatively high number, it is uneconomical, though you used to buy a cheap gas boiler, but all the cost is still reasonably high, and the gas boiler full of danger, high demand for security measures. If you choose electric boiler (that is, the kind of electromagnetic boiler instead of electric heating), capital of electromagnetic boiler itself is relatively high, after all, is a product of modern, high-tech, itself is not high-tech gas-fired boiler. If a region of relatively cheap price, it is highly recommended to use electric boiler. Plus electric boiler is the new environmental protection equipment, all kinds of pollution does not occur is in line with the development trend of the times. Fully automated equipment, personnel do not need guards. Calorific value gas in a wide range of heating season / purity of non-compliance (even if the contract explicitly re-appointment), and the calorific value of more basic electrical 1: 7, the proportion of LNG to be higher, lower coal bed methane (calorific value is multiplied by the thermal efficiency of the device ). In this case, saving electricity than gas about 1/3, according to the grapevine, is expected this year, Liaoning low power dropped to less than 0.3 yuan (business), that electricity than gas savings will exceed the estimated half. Other regions such as Xinjiang, Inner Mongolia, are relatively low price, is very suitable for power boilers. It covers an area of ​​respect, if the gas to create a gas station, then it must be a space-saving electric boiler and electric boiler is the basic module assembly, covers an area of ​​very little, according to the actual situation; and gas boiler explosion venting port and must demand of security area. Natural gas boiler manufacturers comes from the power point of view, electricity is no waste, waste gas, waste water, renewable power, gas emissions is still there, petrochemical and power is not renewable, although countries in the generosity of view, the price decline in space more large, but also more conducive to the use, in particular, Valley electric. Ultimately, if it is 30 000 m2 of non-continuous heating conditions (such as schools, shopping mall, office, public venues, factory, warehouse, etc.), advocated choose electric thermal storage boilers, the best choice for 10kv high voltage device, you can save some investment, and the province as well as policy. But if the area is less than 10,000 m2, the election 0.4kv low-voltage equipment is also good. Equipment and electric boiler is automatic operation, do not need special duty, usually around six meters do not consider lifting frame height coefficient, the heating time can be self-control, these areas are relatively municipal district heating is also very advantage. So gas boiler and electric boiler has its own advantages, depending on the actual situation in each region to decide, but to distant viewpoint in terms of selecting the electric boiler is still relatively cost-effective. In recent years, due to air pollution, coal-fired boilers were fire. Gradually immersed in people's day sideways fuel gas hot water boiler. But coal-fired hot water boiler fuel to bring our lunch together, but also brought us a little problem. That's hot water boiler should be how to maintain? Below small way to tell us hot water boiler maintenance: 1, according to the water quality around, once every six months cleaning operations, the eradication of hot water boiler scale, otherwise, simple convection tube fouling, resulting in convection duct obstruction and burn. 2, if found suction force reduction furnace, the furnace should be cleaning, the furnace door, or in the neck of the chimney with a rubber hose running water flushing. Scale furnace can be opened to eradicate the use of at least 1 year after the manhole survey scale thickness, plus cleaning detergents, can also be added 5-10kg caustic soda or hydrochloric acid 24-36h, add boiling furnace furnace cleaning wash. 3, the operation of the boiler water or hot water to stop the combustion of dry, to avoid the formation of disturbances, severe dry furnace if found, immediately interrupted heating boiler After cooling, to identify the reason, troubleshooting. Must not the temerity to add water, avoid cracking furnace hit. 4, when the winter shutdown, it is necessary to put the net water furnace, hot water boilers to avoid freezing. 5, when the summer without hot water boiler, furnace should put the net water, dry curing with lime. 6, hot water boiler operator skill necessary to operate, grasp the hot water boiler functions, procedures and processes, to eradicate illegal operation.

Other Products