China Supplier Oil Gas Fired Boiler Steam Boiler


China Supplier Oil Gas Fired Boiler Steam Boiler

Details installed gas boiler combustion system that we need to pay attention when installing a gas boiler combustion system, inviting professional staff in advance of the circuit diagram design, so that when installing the status line installation will not appear unreasonable. Also, pay attention to install some fire-fighting equipment, which can provide protection for our security. Unit ventilation should generally remain the total combustion air amount at the rated load. Combustion process controller provides a separate set of contact start-stop control. May be formulated in a variety of burner start-stop loop cascade control relay 10A is a fuse, relay start-stop control stops the control terminal may be connected to the burner, may directly control the power of the burner. Both constant pressure sensor, water power, fuel, gas pressure set value is detected after the automatic controller opens. Time pressure sensor, water supply, oil, gas, and their detection circuit, alarm and found the problem immediately shutdown flame protection, the controller automatically displays the point of failure, an alarm sounds machine. Installation room oil, gas line gas boiler, boiler room should be strictly in accordance with design, specification, and should refer to the burner. Fuel system pressure test after installation is complete, should be 1.25 times the working pressure (minimum test pressure of not less than 0.4MPa). After the fuel pipe installation system should be flushed with water or steam flushing, flushing should have approved technical measures, the number of washing is not less than the secondary blowing, blow up until the clean medium, should be cleared after the purge debris and dead. After installation of fuel system should be oil circulation system-wide test. The gas should be the shortest route to the burner, the air supply pipe diameter must be larger than the constant value parts of the burner duct.

How to choose a china supplier oil fired boiler steam boiler heat exchanger? Steam boiler heat exchangers are generally divided into two categories, one is a direct contact heat exchanger, and the other is an indirect heat exchanger. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. They are used to recover flue gas heat, to achieve energy saving effect of the separation device. In general, conventional steam boiler can be increased by a simple transformation of energy-saving effects, such as increased waste heat recovery installation, which is energy-efficient steam boilers advantage. To promote energy saving is largely the cause of the country, to create more profits for the company, cost savings. Choose a good heat exchanger is one way to achieve energy efficiency goals. Direct contact heat exchanger is a steam boiler with heat recovery and a high ability to remove pollutants in flue gas, but acidic water quality, not easy to use in hot water heating boiler. The so-called indirect heat exchanger, thermal energy means that we recovered from the condensed-called flue gas. Today, more and more people choose to use the steam boiler, the proportion of the market is also increasing. Such steam boiler flue gas discharged contains a large amount of steam, by condensation and release large amounts of latent heat of vaporization. Coal-fired boiler efficiency is much higher than coal-fired boilers. This boiler has a good effect on the selection of the indirect heat exchanger.

Inside the Fangkuai boiler plant, there is a special corrugated furnace bladder production line, which can be processed according to the computer setting mode. At the same time, this is also a unique processing technology of Fangkuai Boiler. The cost of natural gas fuel alone exceeds 5 million yuan per year. The corrugated furnace liner fired by this production line can not only increase the heating surface of the boiler, but also alleviate the damage caused by the thermal expansion and contraction to the combustion chamber, and greatly extend the service life of the boiler.

Henan coal-fired boiler plan according to Henan authorities learned that, as of October 31 this year, to central heating in provincial cities, provincial tube county, county and other built-up areas within the area covered so the organs and institutions and railways, housing residential, hotels, baths and other coal-fired boilers are dismantled or clean the transformation of objects. 11 months ago will be completed 849 sets of 10 tons of steam coal-fired boilers and removal of the following, or the transformation of clean energy. For the clean energy transformation principle is that burning natural gas, liquefied petroleum gas, electricity, biomass briquettes, coal gas and other clean energy programs in addition to the completion of the boiler or dismantling of the unit, the province will also give some financial subsidies. Will also Chaigai boiler as markers official standard for the principle of demolition is not able to recover the use of a standard boiler. That theme boiler must be removed, the chimney must be removed, associated piping and wiring must be removed or cut off, boiler-related write-off procedures. If you can not practice the subject matter must be removed to dismantle motors, blowers and other major equipment

Other Products