Boilers For Chicken Farms


Boilers For Chicken Farms

Due to the fast production side of the boilers for chicken farms already has a very high combustion efficiency, so basically up to 10,000 square meters of factory buildings or residential district heating area can be provided with one ton boiler, in other words: the use of 10,000 square meters heating area 1 ton heating boiler, heating area of ​​20,000 square meters using two tons of heating boilers, can use this analogy down.

The advantages of low nitrogen boilers for chicken farms What? Low nitrogen boiler we use today is based on the original boiler on a certain transformation, and improved some of these features in order to play a role in protecting the environment, which is a favorite one of the main reasons to use this product, it also has many other advantages. Specifically, the advantages of low nitrogen boiler includes the following aspects. First, a low nitrogen environment for low emissions of nitrogen boiler, the experts of its special structure design and generally used are back structure can be made by mixing the fuel inside the furnace can be designed in such a furnace to obtain a sufficiently without any residual combustion, and therefore a certain energy-saving effect. At the same time a low nitrogen boiler flue gas also uses advanced technologies such as an outer loop, which effectively enables the NOX emissions decreased significantly and to achieve the following standard protection of the environment. Second, the heat transfer efficiency in which a low nitrogen boiler combustion process is started, the generated heat can be transmitted very efficient, because a very good thermal conductivity resulting in a lot of heat is not wasted in the middle. This is because the experts to be able to step closer to a more efficient use of energy and the use of new technology equipment installation and manufacturing process of the product in overcoming some of the problems of heat conduction terms before, a professional low nitrogen boiler manufacturers emphasize this to optimize heat transfer effects and improve performance in this area and reduces the cost of the boiler to some extent. Third, high-quality casting material for low nitrogen boiler, if the premise can maintain stable performance long service life is much lower cost can be saved. Therefore, for regular manufacturers of low-nitrogen boiler using very high quality casting material in which the manufacturing process, it is possible to ensure a long service life, in particular pipes made of a material very good very strong and durable to heat will not be long-term and a gap, which can ensure a long time use. These are the aspects of the advantages of low nitrogen boiler included, in addition, it also has a key start-stop function, simple operation can bring great security. Imports of low nitrogen boiler burner manufacturers emphasize especially among modern equipment in many cases the use of automation and control, so now the low nitrogen boiler also introduced this technology, so that manipulation can be very easy to complete the operation of the boiler and is not easy to have caused the problem and to ensure its stable performance of the play.

This paper introduces the common faults of steam boilers for chicken farms and submersible pump steam boiler water level device, causes and solutions. 1, the common problems of steam boiler water level device and its causes: 1, the installation of water level device is too low; 2, water level device, water pipe is too thin; (3) when there is low level device or when using automatic display instrument of water level, there is only one level device on the boiler; 4, water level device discharge water screw plug no ground drain pipe; 5, one water level on the drum is valid, while the other is damaged; 6, the cock on the water level cannot be screwed; 7, the cock on the water level is leaking, the water leak; 8, the false water level is displayed on the level meter; 9, the pot is not screwed up; 7, the cock on the water level is leaking, 8, the false water level is displayed on the water level device; 9, the pot The water level of the two water level devices on the cylinder is inconsistent; the glass tube of the water level device is often broken; 11, there is no protective device for the glass tube of the water level device; 12, the high and low water level indicator on the glass tube plate of the water level device does not indicate the red line; 13, water level glass tube plate is too dirty, the water level can not be observed clearly. The main reason for the above 1 / 4 is the dislocation of design, installation or modification. When a steam boiler is equipped with a low-level water level, there is only one level on the drum, because the balance of the low-level water supply is short-circuited (it was not detectable at the time). The resulting low water level shows a high water level (so-called full water). And the water level on the drum shows a low water level (or even may not even see the water level), when the boiler worker will check the water level on the drum because he is unable to immediately determine the actual water level of the boiler. Therefore, the container will delay the time and the boiler serious water shortage accident. Some even over-trust the display water level of low-status water level devices, and take a large number of sewage discharge, mistakenly treat the steam boiler water shortage as full of water accident, accelerate the occurrence of accidents, there is a precedent for the occurrence of such accidents. Then, the main cause of the above-mentioned 5 # 9 failure is that the boiler does not flush for a long time and does not carry out daily maintenance, which causes the water level of the boiler to be kept in operation for a long time. Cork rust, steam, water pipe clogging, or lack of fillers or aging deterioration. The phenomenon of false water level, except that steam, water pipe or cock is blocked, may also be caused by the dislocation of the connection between steam, water pipe and water level apparatus; Steam, water cock handle position misplaced resulting in cock closure, but also due to poor water quality, steam and water in the boiler concomitant and false water level. The main cause of glass tube breakage of water level apparatus is that the center line of steam and water cock is not in a straight line, the glass tube has bending stress, and the glass tube has no expanding gap. The water level device is being blown directly by the cold air at the window, as well as the poor quality of the glass tube and so on. Submersible hydropower Pumps are mechatronics high-tech products. In recent years, great progress has been made in seal, insulation, cooling and monitoring of submersible pump, and the automatic coupling of pump and outlet pipe has been successfully realized, so that the popularization and application speed of large caliber submersible pump is accelerated obviously. As a result of saving investment in engineering, the submersible electric pump station can be installed and overhauled quickly, the operating conditions are greatly improved, and the reliability and service life of the equipment are significantly increased. At present, our country not only produces and installs axial-flow pumps and mixed-flow pumps with large caliber below 900 mm, but also produces large-scale submersible pumps with a diameter of 1.4 meters and 1.6 meters for submersible electricity. The technical popularization of pumping station has laid a good foundation. Divers are not afraid of flooding, but also have the advantages of rapid removal and installation of good mobility, can cope with the sudden rise of water level, chestnut chamber flooding and other sudden changes, large-scale submersible electric pump changes.

This is our first collaboration with fast boilers for chicken farms, professional and caring service fast boiler's impressed us. From pre-sales advice to after-sales guidance, every step is very careful and thoughtful. They provide hot water boiler performance is also very good, and effectively improve the level of our heating units. --customer feedback

Other Products