Best Oil Steam Boiler Manufacturers


Best Oil Steam Boiler Manufacturers

Combustion gas treatment and a malfunction due to gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer. Second, the gas boiler the ignition spark rod misfiring but the reasons: 1, the disk space ventilation carbon cyclone is blocked, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Burner gas treatment increased noise: ① the check valve in the oil line is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Zhejiang Yiwu issued the "Yiwu winning Blue Sky Battle 2019--2020 action plan." Plan to improve air quality, enhance people's happiness index target put forward concrete measures of implementation, as follows.

1, vigorously develop clean energy. In-depth implementation of the "creation of a national clean energy demonstration Zhejiang Province Action Plan (2018-2020 years)" "Zhejiang three-year action plan for natural gas development (2018-2020 years)" and "Jinhua" Thirteen Five "Renewable Energy Development planning". According to "gas of the gas should be '' should the electric power" principle, energy companies actively guide clean energy alternative embodiment, in 2020, the proportion of the power in the final energy consumption of clean energy consumption accounting for the higher level, the city gas consumption amounted to 150 million cubic meters.

2, control total coal consumption. Strengthen energy consumption and total energy consumption intensity dual control, strict new coal project access, new (modified, expanded) construction project coal consumption reduction of coal instead. By 2020, the city's total coal consumption by 2015, down from more than 5%. Continue to promote alternative energy coal and oil, replace reached the national requirements. No new 35 t steam / hour or less polluting fuels boilers. Strengthening coal quality control, promote clean coal utilization. Before the end of 2020, clean coal utilization rate of 92%, the proportion of electricity than to accept deliveries in 2017 significantly increased.

3, to carry out comprehensive improvement of coal-fired boilers. Increase efforts to eliminate small coal-fired boilers, the urban built-up area basically eliminated tea furnace, operating a stove, grain storage and drying equipment, coal-fired facilities; basically out of 10 steam tons / hour and 35 steam tons / hour coal-fired boilers. 35 t steam / hour and more polluting fuels boilers completed ultra-low emissions and energy transformation. Low nitrogen gas boiler basically completed the transformation. Strict control of the new urban area of ​​biomass boilers. Biomass boilers should be dedicated boiler, blended prohibit other fuels such as coal, and other supporting efficient dust bag embodiment, non-coal, oil, natural gas-fired boilers and the like directly Burning biomass briquettes.

4, the positive development of central heating. Cogeneration units to increase the technological transformation efforts, speed up the heating pipe network construction, improve the heating capacity and the full release before the end of 2020, phasing out the cogeneration district heating pipe network coverage and high pollution coal-fired boilers in the range. In the area where no cogeneration district heating conditions, a plurality of existing small coal-fired boilers, an alternative construction of large-capacity coal-fired boiler in accordance with the principles of the reduction or the equivalent.

5, deepening the construction of high-pollution fuel combustion zone ban. According to "adjust Yiwu prohibit the use of polluting fuels sales area plan" (Yi Zheng Ban Fa [2018] No. 180) documentation requirements, a comprehensive investigation and eliminate high-polluting fuel facilities within the city, to ensure that no dead ends, no blind spots, Finish high pollution fuel combustion zone ban burning building before July 2019.

6, improve energy efficiency. Vigorously develop, promote energy efficient technologies and products to achieve key energy industries, energy-saving equipment standard full coverage. New energy-intensive projects per unit of product (output) energy consumption should reach the international advanced level. Local conditions to improve building energy efficiency standards, and increase efforts to promote green building, city guide implementation of green building standards for new buildings. Renovation of existing residential buildings to promote energy conservation, encourage rural energy-saving housing.

Henan daily operation of the gas boiler 1. Contact chemical maintenance, turbine attendant prepare enough desalinated water, oxygen, water passing temperature no higher than the drum wall temperature 50 ℃; Sheung during hot drum wall temperature should be , metal temperature is not more than 40 ℃. 2. After the new installation or repair before Henan Gas Boiler Feed recorded once ministries indicate expansion. 3. Sheung summer time less than 2 hours, at least 4 hours in winter, when the temperature and Sheung drum wall temperature difference of less than 40 ℃ 4. How Henan gas reheater boiler corrosion protection? (1) turbine playing gate , to ensure that a boiler blower, preferably a cross ID fan, two reserved oil gun. (2) open to the air reheater exhaust steam reheater hydrophobic air door and the door be preserved, to be preserved reheater predetermined temperature below 400 deg.] C for steam. (3) controlling the drum water level within an allowable range. (4) to ensure that the chamber negative pressure 50--100Pa, each of the flaps open, baffle for ventilation less than 5 minutes, stop sending, Fan, each of the flaps closed tailgate may be appropriate to accelerate Sheung speed.

WNS4-1.25-YQ fuel gas-fired boiler WNS4-1.25-YQ fuel gas-fired boiler WNS4-1.25-YQ fuel gas-fired boiler can be widely used in hospitals, schools, textile mills, garment factories, supermarkets, garment factories and other units. It is an efficient, low consumption, low pollution of green products. Capacity: 1-130 tons of steam, thermal efficiency: ≥95%, applicable fuel: natural gas, light oil, heavy oil, gas, etc. Application: central heating, public heating WNS4-1.25-YQ fuel gas-fired boiler various technical indicators have reached the world's advanced level, truly clean burning, non-polluting emissions, easy operation, ample output.

Other Products