Argentina Gas Fired Steam Boiler


Argentina Gas Fired Steam Boiler

The main difference between the gas boiler and gas argentina fired steam boiler What is the main difference between what gas boilers and gas steam boiler is? Nominally, a clear distinction between gas and steam boiler wherein the boiler fuel gas is different. The former use of natural gas, which uses coal. I think a lot of user concerns boiler is why they should cancel gas-fired boiler, because many people have purchased and used the gas boiler. If they switch to gas-fired boiler, it will be a huge expenditure. First, according to the current direction of development of the ecological environment of China, gas boilers will gradually be replaced by gas-fired boiler or other clean and green energy boilers, gradually withdraw from the stage of history. To say a big difference between the gas boiler and gas steam boilers, gas-fired boiler is mainly due to the elimination of environmental protection. From the fuel supply portion, only a gas boiler tube connected to the boiler; gas boiler needs coal field, coal (with or artificial), coal transportation, handling, storage and loading of coal boiler process. It will produce dust, causing serious pollution to the people's living environment. From the point of view of atmospheric emissions, natural gas is very small dust content, substantially negligible; high ash content of coal, the ash content of about 10-30%, the combustion smoke. If dust emission reduction facilities, emissions will increase; if more dust removal facilities, the corresponding costs will increase, this is not a long-term solution. In addition, the sulfur content of natural gas is very small, dust removal, desulfurization and denitrification can get gas boilers, gas boilers need only consider the denitrification problem. From the other point of view of waste disposal, natural gas substantially free of other contaminants, especially in city gas. In the case of coal, the coal field (especially small boilers mainly built in the open air) to produce coal slurry water during the rainy season, or sink into groundwater. When entering the surface water, the combustion ash conveyance of dust is generated. Of course, there are differences also in other ways. For small boilers, gas boilers are more energy efficient than gas boilers, equipment flow is simple, small footprint, low operating and maintenance costs, and so on. These are the main difference between the gas boiler and gas steam boilers, as well as the significance out of gas boiler. As can be seen, the use of gas-fired boiler is the trend of the whole society.

Gas boiler precautions required during installation methods, or steps :( a) a foundation base of the boiler should be provided is determined according to the local soil, manufacturers design reference by the civil sector again. After reaching the base strength boiler, the boiler should drawings inspection and acceptance, and to draw the whole boiler three reference lines: a, longitudinal reference line - drum center or the center of the combustion apparatus. b, lateral reference line - the center of the front axle or chain grate slag centerline of the machine. C, elevation reference line - can be selected from a number of locations about four weeks, respectively, on the basis of the marking, the relative offset between the markers should not exceed 1mm. Furnace in place. After assembly the lower part of the boiler in place first, then the upper assembly large, the upper and lower portions need to find a combination of two positive pads firmly, should be both inside and outside the two casting. Installation location and size deviation test methods according to GB50273 "boiler installation engineering construction and acceptance" implementation. (B) lifting the boiler, during lifting, should be suspended on a lifting lug drum boiler ready large, the boiler on a foundation base coincides with the pre-drawn reference line. The longitudinal centerline of the boiler and the foundation, the deviation is not more than 3 mm, and the inclination with the center line of the drum hammer correction, allowing the central drum inclination is not larger than 5 mm, otherwise use horns foundation base and the junction pad level. Maximum level (c) Installation of boiler network (1), water supply conduit installation requirements typically require as backup pool below the normal water level line of the boiler, so as not to shutdown, boiler feedwater flowing into a large number of drainage caused to start the next . At the outlet of the tank (i.e., an inlet feed line) should be installed wire screen. (2), a main steam line installation requires the main steam lead pipe straight run section should be more than 0.5 m, the bending radius should be 4-5 times the diameter of the pipe, the trap should be fitted at the lowest line in order to prevent water hammer pipe, while to be reliable insulation. (3), the safety valve should be installed in the valve installation requirements after the hydrostatic test, the safety valve shall be fitted exhaust pipe, the exhaust pipe of the safety guide outside the boiler house, allowed valving the exhaust pipe. (4), mounting a lower water table level table downcomer must access a safe place, Hancock rotating flexible water table, not leaking, water table must be installed to the lighting device, easy to observe. (5), a pressure gauge mounting means so that when the scale gauge vertical plates, should be painted red gauge scale to show the maximum allowable pressure boiler, rotating flexible plug gauge, not leaking, water flow, pressure gauges insulation prohibited. (Iv) the boiler chimney installation requirements, when lifting the chimney, the chimney should be straight, horizontal direction lead length should not be too long, generally less than 5 meters, the height of the chimney should comply with relevant national standards. To add chimney rain cap, the weight of the chimney should not fall directly on the boiler chimney take over the host. Installation (e) combustion system: 1, according to the combustion system of FIG power line control circuit, a control signal line and the control line is electrically connected, the program should be installed reliable ignition and flame failure protection devices. Combustion process controller provides a separate set of contact start-stop control. May be formulated in a variety of burner start-stop loop cascade control relay 10A is a fuse, relay start-stop control stops the control terminal may be connected to the burner, may directly control the power of the burner. Both constant pressure sensor, water power, fuel, gas pressure set value is detected after the automatic controller opens. Time pressure sensor, water supply, oil, gas, and their detection circuit, alarm and found the problem immediately shutdown flame protection, the controller automatically displays the point of failure, an alarm sounds machine.

Under the guidance of our customers professional and technical personnel, the full solution of the fast square excellent products and brand strength, our company is very interested in several steam products, finalized the purchase of three 1.25MPa, respectively 2 tons of steam , 4,15 (WNS2 / 4 / 15-1.25-YQ) and two 1.6MPa, steam tons the amount of 4,10 (WNS4 / 10-1.6-YQ) integrated condensing gas boiler steam, and hope to establish with our company long term cooperative relations.

Why condensing boiler sales will increase every year? Under the influence of the modern concept of energy saving in the purchase of products like heating is more popular in condensing boilers, statistics confirmed that showed sales rising year by year in the state during the years of research and development come out of condensing boilers. So why year after year of rising sales of a full range of condensing boilers do? We will be analyzing the reasons for the rise in sales of condensing boilers below. One reason, can save heating costs are well known in the modern condensing boiler has not yet come before people in many parts of the device only by means of conventional boiler when heating is influenced by the principle of cause conventional boilers spend a lot of energy to release some heat . But they have very different condensing boilers and conventional boilers in the design and working principle of the above, the use of modern release can save heating costs on top of a relatively large amount of heat condensing boiler to a certain extent. Two reasons, can reduce the frequency of replacement of modern heating equipment currently on the market of raw materials existing ordinary boiler product is mostly copper, after long-term use of corrosion and thus vulnerable to a series of failures to be replaced. Condensing boilers produced material was stainless steel, even if the contact during operation of the steam does not affect their quality will be able to make virtually modern replacement frequency heating apparatus is controlled. Class three reasons, the release of a very small amount of nitrogen oxides during the operation most of the conventional type boiler in operation of heating equipment are required to coal-derived material as a raw material, coal or the like at the time of combustion of the material will release a large ships harm air quality material composition. While condensing boiler during operation of the steam is produced after combustion of natural gas as a raw material, and therefore the operation at the time of release of the content of nitrogen oxides is much lower than a predetermined standard. Analysis of the reasons condensing boiler sales rising year by year made temporarily come to an end. Through the above three reasons we can have some understanding of the advantages of using credible condensing boiler from the side, I believe that with these advantages condensing boiler different from the ordinary boiler heating equipment will continue to grow in future sales.

Other Products