8Th Oil Fired Steam Boiler For Hot Press


8Th Oil Fired Steam Boiler For Hot Press

Dairy production and processing sectors, need a lot of steam on food drying, sterilization, stereotypes, such as processing, 8th fired steam boiler for hot press essential. Xinjiang Ake Su Xinnong Dairy Co., Ltd. as a local brand, has a large market users. 2016, Akzo increased demand for dairy production, the original steam boiler company can not meet today's production needs. In the same year, Akzo dairy cooperation with our company, signed a series SZS 6 tons of steam pipe steam boilers, steam support for the dairy industry dairy production Aksu.

Henan gas boiler surroundings in claim (1) prohibition of the various stacked Henan combustible gas in the boiler room, not allowed to bake anything Henan gas boiler and steam pipes. Cotton wipe oil equipment, oil rag to a safe place. (2) prohibit incineration in Henan gas boiler waste paper, waste wood, linoleum and other waste, to avoid causing a chimney fire fly, ignite surrounding combustibles. Around (3) Henan gas boiler can not be an ignition source is not close to the other heating boiler pipeline equipment. In addition, we must pay particular attention: Once Henan gas boiler appears dry (red-hot), turn off the power immediately, open all exports, remove the burner. Prohibited immediately cold water into the furnace body should wait until the natural cooling. In order to avoid or reduce the casualties caused by the explosion of a gas boiler and its social, economic losses, we can adopt a more efficient boiler explosion-proof alarm system. For example, possible to detect the concentration of combustible gas leak sensors and alarms. Domestic and now have been developed using a gas sensor, a gas leak can be utilized, for measuring combustible concentration to alert the boiler furnace. The alarm high sensitivity, fast response time made of semiconductor material, the combustible gas sensor feel gas leak alarm immediately. Water spray system can be used as preventive measures early boiler fire and explosion. With the development of technology, artificial intelligence, and more high-tech will be applied to prevent an explosion in Henan gas boiler in the past.

Gas boiler Burner Failures and gas boiler burners Failures and - best  a gas boiler, gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer. Second, gas boiler, but spark ignition rods misfire reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Measures are: Clear; first wash, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel); Check tubing and oil filters, insulation equipment ; remove peripheral screw pump, carefully remove the cover inside out oil network, with immersion oil; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing instability reasons: 1, the air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, fuel oil boiler water. Action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; approximately set to about 50 deg.] C; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Processing methods: ① the oil line check valve is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Natural gas boiler is a kind of thermal energy conversion equipment, which uses natural gas, liquefied gas, city gas and other gas fuels as fuel to burn the heat released from the furnace, heat the water in the pot, and make it vaporize into steam. Water in a pot (drum) is constantly heated by the burning of gas fuel in the furnace to heat up the temperature and produce pressurized steam. Because the boiling point of water increases with the increase of pressure, the pot is sealed, and the expansion of steam in the boiler is restricted to produce pressure to form a thermal force. Strictly speaking, the steam of a boiler is heated to saturated water and vaporized in the drum at constant pressure. It is widely used as an energy source. Natural gas boiler heating In order to protect indoor warmth and human health, so when choosing natural gas boilers, safety issues are very important, and quality issues can not be ignored, only with good quality, in the use of more assured. Some services can also be done better, the choice of heating is customer satisfaction. Understanding natural gas boilers is certainly a need to know the sales situation of the products, if the natural gas boiler reputation is good, it is still very good in comprehensive aspects, worthy of consumer choice, the conversion of performance and thermal energy can also be consulted. There will be no problems when used like this, and there will be no need to worry about electricity during installation The pressure is not enough. Natural gas boiler shut-down method: after stopping the powder feeder, blow the primary duct for 5 minutes before stopping the oil gun. Oil guns should be blown one at a time, not multiple at the same time. After blowing the gun, ventilate the furnace of natural gas boiler for 5 minutes for 8 minutes, and the air volume is not less than 20% of the rated load. To remove combustible material from the furnace. According to the fuel, natural gas boiler can be divided into natural gas 8th fired steam boiler for hot press, city gas steam boiler, coke oven gas steam boiler, liquefied petroleum gas steam boiler, etc. According to the structure form, it can be divided into vertical steam boiler and horizontal steam boiler. Natural gas boiler is shell type Full wet backflow three-way pyrotechnic tube structure, flame combustion in large combustion chamber micro positive pressure combustion, complete extension, low combustion heat load, high combustion heat efficiency, effectively reduce the exhaust temperature, energy saving and consumption reduction, use more economical, The heat absorption strength of the boiler is improved by adopting the structure of corrugated furnace tank and threaded smoke pipe, and the heat exchange surface is expanded to meet the need of heat expansion. It is scientific, reasonable and durable.

Other Products