8 Ton Oil Fired Boilers In Indonesia


8 Ton Oil Fired Boilers In Indonesia

Since last year, the city of Yinchuan in Ningxia to develop clean energy alternative to coal heating work carried out, in order to adhere to the use of waste heat energy-based heating system, two years, a total removal of 212 coal-fired 8 ton fired boilers in indonesia units, designed over 20 million square heating area Meter. At present, Yinchuan City, the formation of a waste heat recovery and cogeneration-based, clean energy co-existence of a new pattern of heating, coal heating gradually withdraw from the stage of history.

According to Yinchuan City Housing Construction Bureau feedback, early last year, Yinchuan City, began to promote the implementation of "East of the West to give a" heat of long-distance heating projects, the long-distance transmission projects across the Yellow River, the basic realization of restructuring heat source, heat source interconnection point to ensure the city heating security and stability, environmental protection is of great significance.

At present, "East of the West to give a" central heating heating net charge of the project, the city branch, etc. have been completed, the east, the city water pipe network has been completed and started flushing cycle, is west of the water, water totaled 145,000 cubic meters.

At the same time, Yinchuan City, also build a heat source, thermoelectric Xixia complete the second phase of construction, the new 2 sets of 350,000 kilowatts supercritical coal-fired air-cooled heat generators, which can effectively replace Yinchuan City, 154 small coal-fired boilers, the annual generating capacity 3.85 billion kwh, heating capacity of 16.42 million square meters.

This year Yinchuan new cogeneration district heating area of ​​41 million square meters, the new heating pipe network 86 kilometers, is the largest investment project ever central heating, with the largest of the year.

How to improve the thermal efficiency of gas steam 8 ton fired boilers in indonesia steam boiler to improve the thermal efficiency of gas is a problem many users are taken, I believe this issue is the direction of each used in the production of various types of gas steam boiler manufacturers have been in the study. Many users at the time of the gas-steam oven operates, often in the actual production process, we found some new problems, but all the problems, the most vexing is the high temperature exhaust gas steam boilers, thermal efficiency than low phenomenon that a serious impact on our work, then how should we do to improve the thermal efficiency of it? need to know this is the best way to meet the low-temperature properties of gas and steam comes as synthetic gas steam. However, the vast majority of synthetic gas and steam biphenyls, benzene derivatives of both components of the complex, or a vapor of volatiles has strong carcinogenicity, it is strongly recommended that the client select the type of mineral oil vapor product gas. Second, gas and steam products to meet the low temperature performance process, but also have a relatively high flash point required. In general, gas steam engineers suggest, low temperature gas steam flash point not lower than the opening 200 ℃. After a professional manufacturer of continuous research and improvement of its equipment, in order to improve its thermal efficiency was found to be increased tail gas steam boiler heating surface of, say, air preheater and economizer. But when organic heat carrier furnace return temperature is high, you can not set the economizer, air preheater can only be set to alleviate the situation. So if no gas steam boiler and other heating systems for low temperature heat exchanger, then the only way to improve the energy efficiency is adding air preheater. After adding air preheater can be a corresponding increase in gas flow rate of steam, gas steam boiler in order to ensure safe, reliable and stable work, the thermal efficiency of gas-steam boiler plant will be a corresponding with the increase.

In order to prevent the occurrence of secondary combustion 8 ton fired boilers in indonesia tail, which is a fundamental measure to prevent combustible material deposited in the rear of the boiler. For this reason, when the ignition, if the point does not fire, must immediately stop the supply of the fuel (e.g., coal, oil, gas, etc.) into the furnace, to prevent the combustible matter into the rear of the boiler. In operation, the soot blowing should be strengthened, with the wind appropriate, complete combustion, no black smoke. After the shutdown, monitor the temperature economizer, if the sudden increase in tens of degrees, already causing spontaneous combustion, fire-fighting measures to be taken immediately.

Gas 8 ton fired boilers in indonesia burner ignition misfire rod reasons gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer.

Other Products