8 Mw Gas Fired Hot Water Boiler For Hotel


8 Mw Gas Fired Hot Water Boiler For Hotel

Steam boiler performance characteristics: steam boiler Features: 1. Boilers faster horizontal fire tube boiler, refrigerant natural circulation. A boiler drum boiler heat exchange system, the left and right water wall header and composition, the main heating surface of furnace wall, part of the boiler tubes and boiler tubes in the convection tubes. This product consists of five main part of the boiler, flue dust, piping system. The first four members manufactured in a factory, can be transported to the installation site for assembly, shorten the installation period, to ensure the quality of the product installed. 2. Advanced Design Performance: main heating surface of the boiler 20 # low-pressure boiler seamless steel, special steel boiler tube boiler. Left and right header made seamless pipe. three. Boiler refractory concrete arch was destroyed. After another bow low and long, and it will burn well. Flue and side wall are made of bricks. Front and rear wall of the boiler use ordinary bricks made. 4. Exhaust flow and reasonable distribution of large combustion chamber, applicability coal. For a variety of bituminous coal or anthracite, mixed coal. very hot. High temperature flue gas enters the first settling chamber, and then into the flue wings from both sides, before re-entering the smoke box, smoke dust good effect. Simple water cycle, the compression pieces reasonable structure, safe operation of the premise of ensuring water quality. 6. The combustion apparatus is a fast loading grate, combustion equipment manufactured in a factory and installed, transported to the construction site may be mounted directly on the foundation. The present invention has a reasonable structure, compact, low steel consumption, performance, weight, size and structure of the boiler with the same capacity has significantly improved compared to the advantage of domestic products. Boiler work process: a substantially uniform coal particles by an automatic stoker coal thrown into the hopper, preheated before entering the arch in the case of rotating chain grate. Were burned in the incineration zone, fell into the slag pool. The high temperature flue gas produced by combustion of the furnace arch port into the furnace from a lower portion of the rear flue two wings, the wings and then heat the flue, through the forward flow before the packets enter the convection heat transfer tube bundle, then the tail tube boiler and dust entering the economizer section, and discharged to the atmosphere through a chimney to the induced fan. Boiler feed water is supplied by a boiler feed pump, demineralized water supplied by the economizer, and then enters the drum, and then enter the downcomer around header. Endothermic steam is generated by vaporizing water wall on both sides, into the steam within the steam separator drum, after separation, the main steam valve into the process heat required.

October 23, the 13th China International Wine & Beverage Processing Technology and Equipment Exhibition (referred to CBB2018) kicked off in Shanghai. Fang Group combine fast wine, the actual needs of users in the field of beverage industry, using its own investment to build more efficient boiler test center platform, continuous investment test and adjust them, to bring the latest "Core Europe" series boilers and condensate recovery system solutions exhibition debut.

The main factors affecting small type gas steam boiler steam boiler thermal stability of gas ignition is not difficult to establish a stable small fire signal, the root cause is a small fire detectors can not detect normal to the fire. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees biomass boilers categories: biomass boilers horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass 8 mw fired hot water boiler for hotel, biomass oil furnace. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. Small fire detectors use the ionization fire detection, and requires effective contact area of ​​the flame, the flame stability and proper size, the gas pressure must be controlled within a very strict range. If the ignition gas pressure is too high, too long a small fire flame is moved beyond the detection range of the small fire detection probe, the system will not be mistaken for a small fire; if the gas pressure is too small, the gas will be firing too small and the boiler the blast very, very easy to blow out the flame, the ignition is not possible. Also, fire gases found a small pressure regulator valve regulating performance is not good, fine adjustment can not be achieved. Stability is also related to a small fire and the ratio of the size of the boiler furnace pressure boiler feed valve. The damper is too large or too small can affect the stability of the flame is ignited and the flame, furnace pressure will lead to extinguish the flame. In order to ensure the accuracy of fire detection, fire detection, we can adjust the small depth of insertion of the probe, the position of the fire detection probe in the correct position, in order to more effectively detect small fires flame.

Gas boiler shutdown normal shutdown process step is one step in the process of boiler operation is essential to understand the shutdown processing methods to ensure more long-term operating life of boiler. When the boiler the following faults can temporarily shutdown for maintenance. Expansion port, leakage rivet joints; tube, the waterwall tubes, damage to the heating surface tube leakage; drum in contact with the flue gas, set top box, a heat insulating material off the downcomer; water supply system, a combustion system, the occurrence of breakage safety accessories . Shutdown of the gas boiler normal (full shutdown, maintenance shutdown) Step 1, in order to stop the burner, for closing the valve. At the same time feed water to the boiler, 2cm above the normal water level reaches the stop water supply, reduce the pressure. 2, close the main steam valve, open the traps, steam boiler, water cut off. 3, the electric boiler feed water control valve closed and the manual valve, boiler feed water cut. 4, steam pressure may be lowered to the water supply and drainage operations alternately 0, the pot water temperature is gradually lowered. When the temperature dropped to 50 ℃ (not hot when hand potshell head with or touch), the entire pot of water may be drained. Should be preceded by opening the drain valve or air valve above the boiler, this time into the furnace maintenance, shutdown must be kept slow cooling, rapid cooling is prohibited. From the shutdown to be able to enter the furnace maintenance, cooling time is not less than 24 hours. 5, sales of more than 24 shutdown, to total gas supply valve is closed, opens the gas pipe to completely drain the subjective dispensing gas.

Other Products