6T Boiler Oil Fired Steam Boiler


6T Boiler Oil Fired Steam Boiler

Inter-regional Pingdingshan Coal Industry Group Co., Ltd. by the Pingdingshan Shenma Group and two Chinese top 500 enterprises founded by restructuring, cross-industry, cross-ownership and transnational business of large state-owned energy and chemical group, under the People's Government of Henan Province , is the most complete variety of coking coal, thermal coal production base, has Asia's largest chemical production base in nylon. Carefully selected and comparison, fast boiler Pingmei cooperation with party has chosen to provide a 2 tons of steam electric 6t boiler fired steam boiler (WDR2.0-1.25-II) by a fast side.

Classification is the use of fuel oil-fired boiler and practical, this boiler is the boiler variety of diesel fuel and waste oil, his overall construction and arrangement of the gas boiler is similar to a common classification of mechanical and steam materialized style.

The characteristics of the fuel gas 6t boiler fired steam boiler: 1, burner gas steam boiler is supplied by well-known manufacturers in the world, burn automatically stop controller in accordance with instructions, a separate control box has a number of security, safety and stable performance, low maintenance. 2, advanced automatic steam boiler controller, Chinese LCD screen, the man-machine interface, the user simply easily set, i.e., according to user requirements boiler start and stop, load adjustment, automatic water supply, such as automatic operation. Boiler fully functional, complete protection, easy to operate, safe, reliable, self-diagnostic function. Boiler operation anomalies automatically interrupt burning, audible alarm once appeared. 3, the steam boiler burner mode is set, double return configuration, fuel combustion, boiler stable; inserted spoiler smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, and reduce cost. Gas fuel oil boiler 4, horizontal steam boiler shell type three return all wet back downstream pyrotechnic pipe structure, i.e. increase the strength of the heat absorption of the boiler, but also to meet the needs of thermal expansion of the heating surface, scientific and rational, prolonged durable. 5, in strict accordance with the present boiler "Steam Boiler Safety Supervision", JB / T10094-2002 "industrial boilers general technical conditions", JB / T1619-2002 "boiler manufacturing technology conditions potshell" requirements, design, manufacture, monitoring inspection to ensure good quality of boilers, achieve low energy consumption, high thermal efficiency, stable pressure, gas and quantity, economic use. 6, a large boiler furnace space, storage, steam and more adaptable load capacity. Rational design of steam separator apparatus built to meet user requirements need to use higher quality steam. Furnace open manhole, head holes, hand holes, to facilitate the internal furnace to clean up, make repairs, maintenance is very convenient. 7, is provided with a multi-stage boiler safety interlock protection: Pressure switch protection (higher than the set auto stop and pressure), low water protection (boiler water level is below the body of the warning level, the alarm and automatically cut off power), the protection valve (boiler pressure exceeds the pressure of work, discouraged automatic blood pressure) to ensure foolproof boiler in a variety of conditions, safe home. 8, the combined organic appearance of mechatronic, sophisticated new, compact, less space, easy to transport and install. 9, using the new material and the thermal insulation quality white color plate package, lighter in weight, good insulation properties, beautiful, not rust.

Henan oil-fired boiler Introduction Product Introduction: Henan oil-fired boiler to run than electric heating boiler economic, easy to use than gas-fired boiler. With economic development and social progress and the improvement of people's awareness of environmental protection, coal-fired boilers due to serious pollution, moving away from sight, replaced by a new environmentally friendly digital boiler, such as electric heating boiler, oil boiler, gas boiler, electric heating boiler is more expensive, gas-fired boilers need to open a gas pipeline, then, if there is no gas pipeline, and hope boiler low operating costs, only select oil-fired boiler. Boot check: 1, various instruments, whether the instrument to confirm the adequacy of fuel tank, and the inlet valve is opened. 2, confirm the soft capacity and the water tank boiler water quality meets the requirements of the main valve is opened and boiler feed water inlet valve. 3, rotation of the oil filter to remove debris. 4, drain the remaining water in the boiler, while the opening operation of the low level alarm and chain. Features: 1, inserted within a fire retardant spoiler tube, slow speed exhaust enhance heat transfer, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. 2, furnace by computer-aided design, each of the heating surface is optimized, compact and reasonable arrangement, small boiler area, high thermal efficiency. 3, the user can set the start, shutdown time, after setting, no special duty, easy, and effort. 4, according to the boiler pressure furnace design, furnace provided with a top opening to atmosphere, the boiler is in an unpressurised state, there is no risk of explosion. 5, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, combustion heat is conducted to a large extent in water, the discharged flue gas temperature is low smoke chamber, reducing heat loss and save fuel. 6, the water level sensor water level real-time monitoring, to continuously monitor the water level is normal furnace. While controlling the temperature and replenishment level sensor solenoid valves, the boiler water may be continuously supplied. 7, water boiler fuel water speed, water volume, widely used in factories, hospitals, schools, etc. required a large amount of boiling water units. Shutdown procedure: 1, when it is desired to deactivate the combustion boiler to the switch in the OFF position, the oil supply is stopped, the flame is extinguished, but the fan is still operating to blow away the residual flue gas in the furnace. 2, when the blower is stopped, the operation OFF switch to turn off the power and then, after closing the steam valve, and the fuel supply valve to close the valve. 3, open the drain valve when the discharge pressure is reduced after the boiler play an open valve, to drain the water in the boiler, and the steam partial open the drain valve to drain the water in the drum segregation. Daily checks: 1, check the water level regulator function: whether the automatic water pump stops. 2. Check flame monitoring. 3, is rotated, the slide cam portion lubricating, and wiping. 4, the flushing water level gauge 1-2 times (class), according to the proper operation, so that until the rinse water level gauge. 5, sewerage 1-2 times (class).

Other Products