600Kg Diesel Steam Boiler Profile


600Kg Diesel Steam Boiler Profile

In addition to long pauses use of gas-fired boilers to note the above operations, the daily maintenance is also very important and must be inspected once every few months we should note that the desiccant, promptly added; and each periodic inspection of boiler parts usage, have something to damage should be repaired or replaced.

Gas boiler furnaces and cooking formal operation of the boiler furnace 1, and its object is to clear the body of the boiler impurities, grease and rust. The inspection of boiler installed and cold test run, each member confirms perfect safety conditions have hot start operation to start cooking stove. 2, boiling out dosage (see table below) Unit: kg / t rust grease Drug Name Notes thicker thin rust grease sodium hydroxide (NaOH) 2 ~ 33 ~ 4 trisodium phosphate (Na3PO412H2O) 2 ~ 33 ~ 4 when no trisodium phosphate, sodium carbonate can be used (of Na2CO3) in place of an amount of 3 to 6 kg / t water. 3, when dosing, the low water level in the boiler water should, boiler water should be the highest level, the drug was added on the stove interfaces (e.g., valve opening) when the cooking stove. 4, the end of the cook should the boiler furnace pressure was kept at about 75% of the working pressure, time is generally 2 to 3 days. 5, during the cooking stove, boiler water periodically take laboratory analysis, alkalinity boiler water of not less than 45 meq / L, should be added or dosing. 6, oven cooking is completed, the drum and the current tank should be cleaned precipitate, rinsing the boiler and in contact with the agent through a valve, to check whether or clogging sewage. 7, after cooling boiler, furnace water will be fully released. Open manholes, hand holes, repeatedly washed with water until the furnace no rust, grease qualified. (Ix) a test run, the test run should be with a load, for 4 to 24 hours (set maximum, minimum operating pressure). 2, observe the safety valve and various safety accessories, protective devices and other operations are sensitive and reliable. 3, after the commissioning of qualified, supervisory inspection agency should be acceptance.

Maintenance of electric boiler

First, we must ensure that the electrical environment boilers should be in a dry, no moisture environment, if too much moisture environments easily lead to electric boilers appear even electrical phenomena occur, causing an electrical hazard.

"Fangkuai" boiler relies on its own products and technical advantages in industrial boilers and automatic control, and uses advanced Internet of Things technology, mobile internet technology, cloud computing technology, big data technology and intelligent control technology with heat sources, heat networks, and thermal users. It is highly centralized to form an intelligent cloud management and control center, which truly realizes the intelligentization of industrial boilers. "Fangkuai" remote monitoring system for boilers has improved boiler operation efficiency; "Fangkuai" boiler cloud service platform allows boilers to learn to think; "Fangkuai" boiler big data allows boiler cloud service platform to have "super brain"; " The real-time monitoring of the “Fangkuai” boiler makes the boiler problem nowhere to hide; the “Fangkuai” boiler 400 service system makes the service more convenient and faster.

Other Products