5000Kg Natural Gas Fired Boiler


5000Kg Natural Gas Fired Boiler

Four coal-fired 5000kg fired boilers precautions to meet a variety of fossil fuels and natural gas sectors of production, often require boiler, the general common is to transform into a coal-fired furnace gas-fired boiler, to change the high fuel costs of coal on the environment cause serious pollution problems, specific issues unique boiler is not a small project, you need to pay attention to a good close links with each transformation in order to avoid failure of transformation, on boiler should be noted that we have to understand the following description. 1, the original boiler demolition work; boiler before carrying out the original host and auxiliary boilers need to be demolished, concrete demolition work carried out by professional staff, in order to more quickly complete the demolition work with but also to prevent the demolition process in the event of any accident; 2, note that pressure capacity of the boiler; small boiler into the gas by the coal-fired, also changed the original negative and positive pressure combustion burner, the process you need to pay special attention throughout the furnace wall the structure and sealing, the sealing function, it might cause the boiler after the transformation could not withstand the pressure and accidents; 3, furnace renovation precautions; when in many cases will change the gas burner, because the fuel mist of poor or incomplete combustion of the fuel gas remaining in the furnace a little mistake will cause fire or explosion, it is carried out after completion of the transformation for an explosion vent installed in an appropriate position to prevent the explosion, while additional ignition flame protection means after the boiler guarantee safe operation; 4, after the transformation of the test; after the completion of high-quality boiler transformation, but also the need for reuse Sophisticated testing to confirm their safety, commonly used test method is boiler pressure after the transformation of high-pressure test, and finally pass a test meet the standard may be considered completed after the entire transformation boilers. Caution visible through major transformation over the course of gas boilers, boiler reconstruction requires not only technical but also need to meet the relevant standards in order to ensure more successful boiler and can be smoothly carried out using, of course, in the transformation of the former users need to analyze the structure of the entire boiler study, confirming boiler renovation project can be re-introduced in order to avoid unnecessary waste.

3 macrotaxonomy steam 5000kg fired boiler steam boiler fuel can be divided in accordance with the electric steam boiler, steam boiler fuel, gas and steam boiler; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler mostly small single, double return the vertical structure, large steam boilers and more horizontal structure of three return. Vertical fuel gas steam boiler burner set under way, double return configuration, fuel combustion, boiler stable; inserted spoiler smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reduce user cost. Horizontal steam boiler shell type three return all wet back downstream pyrotechnic pipe structure, the combustion flame in the combustion chamber large positive pressure, fully extended, low combustion heat load, the high heat of combustion efficiency, effectively reducing the exhaust gas temperature, energy saving and economical use. Waveform threaded pipe and furnace structure, not only improves the strength of the heat absorption of the boiler, but also to meet the needs of thermal expansion of the heating surface, scientific and rational, and durable.

In the transformation process, side by rapid technical engineers FGR advanced combustion technologies, the use of flue gas recirculation and the outer loop is provided, withdrawing part of flue mixed with the combustion air, and then into the furnace through a burner, not directly part in the combustion, by reducing the effect of the combustion flame temperature to reduce the temperature and oxygen concentration, to achieve the purpose of reducing NOx generation. For now, for a large volume of gas 5000kg fired boilers, low compared to the overall transformation of nitrogen to replace the boiler equipment will save a lot of costs. Fast boiler has a boiler in research and technology low nitrogen aspects of considerable industry experience, successful completion of the reconstruction project Dingzhou low nitrogen Erie boiler, significant cost savings for businesses.

Analysis and pressure steam 5000kg fired boiler burning issues of excessive treatment: this kind of boiler steam boiler, because it is an important site for the product, so in their knowledge and understanding of the, at least, should achieve a comprehensive and specific to this extent, so in order to further the product site, rather than just stay on the surface, and then, in the use of the product, there is a good use of effects. Therefore, in order to achieve the above objectives, the following will continue this topic, which reads as follows. 1. steam boiler, which is in use, whether the boiler must first obtain use permits, and then to use this kind of boiler? In addition, if classified according to their fuel, then, in particular, which has several? Steam boilers, because it belongs to special equipment, therefore, can not be directly used, relevant departments should first obtain use permits issued by the boiler, and then to use steam boilers. In addition, this kind of boiler, if classified according to the type of fuel, then, can be divided into three electric steam boiler, gas steam boiler and steam boiler fuel.

Other Products