4T 6T 10T Heavy Oil Fired Steam Boiler


4T 6T 10T Heavy Oil Fired Steam Boiler

Due to the surge in demand for urban underground pipeline maintenance engineering, Hwashi pipeline urgent need to buy into a hot water boiler. Fast boiler remains firmly committed to do the clean, environmentally friendly, efficient and intelligent boiler equipment, respond positively to the national green development strategy, which Hwashi pipeline business philosophy coincide. The two sides after making good communication, confirmed that two tons can provide a mobile gas pressure hot water boiler by the fast boiler. WNS series mobile gas pressure hot water boiler this boiler to provide quick power of ingenuity to create a fast boiler, while both the clean and efficient environmental protection and safety features, under the premise of a breakthrough thermal efficiency of 98%, smoke temperature below 90 ℃, suitable for use in urban areas.

Introduction of fuel gas-fired boiler fuel gas-fired boiler Product Description: Fuel gas-fired boiler fuel but also refers to both gas boiler. Only boiler fuel called oil-fired boiler, gas boiler can only be called a gas boiler. If the configuration boiler fuel gas or dual fuel burners, then the boiler is oil or gas boiler. Fuel gas-fired boiler is a more general concept, fuel gas-fired boiler is divided into water boilers, hot water boilers, 4t 6t 10t fired steam boilers and thermal oil boiler, according to their own use to select a different fuel gas-fired boiler time of purchase. Fuel gas-fired boiler is different from coal-fired boilers, which requires the use of a burner fuel is injected into the boiler furnace using a combustion chamber without the use of fire grate facilities. Because not produce fuel ash after burning fuel gas-fired boiler, fuel gas-fired boiler so without slagging facilities. Oil injected into the furnace, if the gas and air mixture within a certain range, or turned off, it is easy to explode. Therefore, fuel gas-fired boiler combustion required to adopt automation and control systems. Fuel gas boiler compact, small boiler and ventilation, water supply, control and auxiliary equipment are arranged on a distribution box, it may also be assembled and medium-sized factory. Advantages: the advantages of fuel gas-fired boiler: 1), high efficiency boilers. 2) simple structure. 3), supporting the use of simple auxiliary. 4), and the whole intelligent automatic control system with multiple levels of protection. 5) equipped with burners (blower) and a flue muffler system, reduce the noise of the boiler operation. 6), should be equipped with automatic dosing unit, the water treatment device. 7), with other monitoring and limiting device should be at least 24 hours to ensure that the boiler safe operation of unsupervised. 8), before starting the first boiler is purged before ignition function automatically. Boiler maintenance: (1) Dry regimen: the boiler furnace shutdown to discharge water, the inside completely remove the dirt, rinse, drying in the furnace with Weihuo (be careful not to fire), and a diameter of 10-30 mm in size massive quicklime installed sub-plate, placed in the drum, without contacting the metal with lime, quicklime weight, calculated to the drum 8 kilograms per cubic meter volume, then all manholes, hand holes pipe valve closed, checked every three months, such as lime ingredients like broken, i.e. the need to replace, should be re-run the boiler and the lime disk unloading. (2) Wet regimen: After Shutdown of the water discharge released, the internal completely remove the dirt, rinse, refill treated water to the full, the water was heated to 100 deg.] C oven, so that the water discharge gas outside of the furnace, then close all the valves, cold climates where moisture can not support the use of law, so as not to damage the boiler furnace water freezes. Structural features; fuel gas boiler is different from the coal-fired boiler, which requires the use of a burner fuel into the boiler furnace using a combustion chamber without the use of fire grate facilities. Because not produce fuel ash after burning fuel gas-fired boiler, fuel gas-fired boiler so without slagging facilities. If the hydrocarbon injected into the furnace with the air mixing within a certain range, or turned off, it is easy to explode. Therefore, fuel gas-fired boiler combustion required to adopt automation and control systems. Fuel gas boiler compact, small boiler and ventilation, water supply, control and auxiliary equipment are arranged on a chassis, the assembly may also be medium-sized factory. Now the main element and the pressure connection of the fuel gas boiler are as follows: 1, the main fire tube boiler pressure parts: the boiler shell, a tube sheet, furnace, smoke pipe; 2, the main pressure element water tube boiler: drum (drum), water wall boiler bank, serpentine tube header; 3, the main pressure connection element fuel gas boiler: the main welding, expansion may be part.

Steam boiler rules Henan fast boiler with small series to introduce the company's 4t 6t 10t fired steam boiler operating procedures. First, the components of the steam boiler before oven cooking oven and check (a) and oven cooked boiler furnace must be checked in detail. Check the following items: 1, cold chain grate test more than 24 hours, cold test should meet the following requirements: (1) grate should be smooth turning chain wheel axle, found arched, two tension bolts can be tightened. (2) the active grate sprocket good occlusion. Minimum gap (3) on both sides of the active grate block with the side seal and the side seal angle not less than 6 mm. Distance (4) on both sides of both ends of the furnace grate platoon leader pin in the sprocket should be kept equal. If it is found at one end to the occurrence of side friction, long waist-hole may be a tap with a hammer, the end surfaces on both sides remains equal distance. (5) steam boiler grate rotated without jamming, deviation phenomenon, when the deviation found by the inspection hole into the rear grate tail, the tie bolt align the two bearings of the drum, deviation phenomenon can be eliminated. The boiler has ignition combustion, still need to transfer found Hearth n, just before two adjustable chain tensioning bolt shaft directly outside the furnace, but preceded align the front sprocket shaft and a gearbox connect the safety pin or bolt removed until after squaring shaft to a gearbox with a chain alignment pin or bolt after tightening, may otherwise result in misalignment with the sprocket shaft of a gearbox and mechanical damage. (B) Check broken grate furnace platoon leader pin is bent, if long waist hole in the furnace may be carried out at any time platoon leader pin alignment reload. (C) a chain grate does not allow foreign matters (such as bolts, nuts, nails and other iron) is present. (D) firing door open and flexible, easy to open and drop the shutter coal, coal gate left and right side of the grate surface distance equal to, the thickness of both sides of the seam to ensure equal furnace, as a method for reducing ranging from links available to make equal, coal shutter cover plate should cover tightly to prevent leakage into the coal, coal stuck shutter. (Five) of each grate windshield of smoke damper and damper adjustment inside the flue flexible switch. (Vi) blower, Fan, Java machine, commissioning normal water supply equipment. (Vii) manhole, hand hole is tight, attached parts fitted Ge are complete. (Viii) the furnace wall is normal, the flue is tight. (Ix) steam boiler pipes, water pipes, sewage road is complete. (J) all filled with lubricating oil in the bearing housing and oil cup. (Xi) All electrical equipment should be empty running test, inspection equipment, and other electrical lines is intact.

Different kinds of specific models boilers and thermal power plants use which: boiler, which from the application point of view, is very broad, and it is still the flagship product box boiler, which also includes different types of boilers, therefore, based on the above it two points, and in order so that we can further awareness and understanding of the boiler, below, will continue to explain the knowledge in this area, never to achieve the above purpose. 1. boiler, whether according to different classification criteria, there are different kinds? Each of its kind, which specific model? Boiler, which according to different classification criteria, there is a different species. So, a question on which the answer is yes, but this is no doubt. Therefore, I hope that we can have a clear understanding. Water in boilers, in which the specific models, are KS-D electric water boilers, KS-Y water boiler fuel, KS-Q water gas boiler, and KS-AII these coal-fired boiler water. Hot water boiler, there CLDZ electric water boiler, CLHS oil hot water boilers and coal-fired hot water boilers and other CLSG these. The 4t 6t 10t fired steam boiler, there LDR electric steam boiler, LHS fuel steam boilers and coal-fired steam boilers DZL these.

Other Products