45 Ton Boilers In Palm Oil Mill


45 Ton Boilers In Palm Oil Mill

Structural characteristics and rational utilization of the power of the furnace structure characteristic electric 45 ton boilers in palm mill hydraulic computing There are two methods for electrical boiler furnace: a designing new electric boiler, first by combustion requirements, according to the selected grate area of ​​the heat strength and the furnace volume heat intensity, determined baked and a preliminary discharge area is determined that the furnace volume, structure and size. Two boilers according to preliminary estimation method is recommended to determine the area of ​​the grate and furnace volume. Now Yaoan claim preliminary heat radiation heating surface arranged in the furnace, and the furnace structure is arranged drawn sketch, thereby performing the furnace structure characteristic calculation. When checking the conventional electric boiler furnace, if its structure is known, the furnace must be characteristic calculation means. Electric boiler furnace structure characteristic calculation means provide the necessary data for the furnace heat. After the furnace when the heat transfer calculation, checking furnace exit gas temperature is unreasonable, the institutions respond to the furnace and the radiation heating surface is arranged to be modified, and then calculated. The surrounding electric boiler furnace volume: Wall roof and around the center line of the plane (if the waterwall tubes covered with a refractory coating live bricks, where the surface is not Wall for Xianghuo arranged to the furnace wall surface of the wall. outlet chimney at the top of a row of tubes centerline) and a bottom surface of the plane. Unavoidable presence of various types of hydraulic oil flowing through the hydraulic valve when the pressure drop and flow loss, energy loss in this portion of the large proportion in the total energy loss. Therefore, a reasonable selection hydraulic, a pressure adjusting valve is also an important aspect of power loss reduction. Flow valve flow rate adjustment system according to the range of the minimum select and ensure stable flow can meet the requirements, the pressure in the pressure valve satisfied hydraulic equipment work properly, try to get a lower pressure. A reasonable choice of hydraulic oil. When the oil flow in the pipeline, will exhibit a viscosity, while too high viscosity, will have a greater internal friction, resulting in heating oil, while increasing the fluid flow resistance. When the viscosity is too low, easily lead to leakage, reducing the volumetric efficiency of the system, therefore, generally choose suitable viscosity and good viscosity-temperature characteristics of the oil. Further, when the oil flow in the pipeline, there is also along the local pressure loss and the pressure loss, so the design of the pipe line as short as possible, while reducing elbow.

Why fuel gas-fired 45 ton boilers in palm mill will turn off? Although the case of gas-fired boiler fuel oil dual boiler, but only that the furnace can be gas fuel, but a normal customer choice is to select a class of the final fuel only, even if a mixed gas, also belong to the category of gas.

Since more than six months since the 45 ton boilers in palm mill equipment, heating and hot water supply well, our technical staff also view real-time remote monitoring and control through the use of the boiler to the scene, Baiyun Quan Lake hotel management staff related to our technical staff gave very great encouragement and affirmation. --customer feedback

How to choose the heat exchanger is a steam 45 ton boilers in palm mill Shandong? To steam boiler insulation damaged condition for viewing prior to use, view of the burner, to see whether the normal operation, but also to see to make sure the valve open position is correct, to view the attachment security equipment, instrumentation equipment and devices automatic control equipment must meet the requirements. Point blast furnace steam boiler admit items are: open oil circulation pump before and after the valve, the valve open oil heating process, mediation high tank level in a reasonable position, admitted that the gas pressure before the gas burner must be burned in power scale, power supply normal.

Other Products