4 Ton Oil Gas Fired Steam Boiler


4 Ton Oil Gas Fired Steam Boiler

Fuel gas-fired boiler fuel gas-fired boiler product presentation is different from coal-fired boilers, which requires the use of a burner fuel is injected into the boiler furnace using a combustion chamber without the use of fire grate facilities. Because not produce fuel ash after burning fuel gas-fired boiler, fuel gas-fired boiler so without slagging facilities. Oil injected into the furnace, if the gas and air mixture within a certain range, or turned off, it is easy to explode. Therefore, fuel gas-fired boiler combustion required to adopt automation and control systems. Fuel gas boiler compact, small boiler and ventilation, water supply, control and auxiliary equipment are arranged on a distribution box, it may also be assembled and medium-sized factory. Fuel gas-fired boiler safety valve installation points introduce fuel gas-fired boiler safety valve needs to be installed in the correct installation steps, in order to avoid mistakes, resulting in what needs to pay attention to danger, fuel gas-fired boiler safety valve installed it? Here, I introduce: 1 fuel gas boiler safety valve should prevent the lever means and movement of the self-weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly . 2. Rated to 0.5t h evaporation boiler fuel gas /, at least two safety valves installed; Rated evaporation 0.5t h or less fuel gas boiler /, mounted on at least a safety valve. The separable exit of the economizer, steam superheater outlet of the safety valve must be installed. 3. Fuel gas-fired boiler safety valve to the boiler tubes, cross-sectional area should not be less than the import safety valve cross-sectional area. If several valves installed together with a short tube directly connected to the drum, short tube passage area not less than 1.25 times the area of ​​all the exhaust valve. 4. Fuel gas boiler safety valve should be installed vertically in the boiler drum, header high position. Between the valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20mm. 6. Fuel gas-fired boiler safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. Safety valve exhaust pipe at the bottom should be fitted to the safe location of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve.

Zhengzhou Sunrise Optoelectronics Technology Co., Ltd. by the Dongxu Group, Henan Province, the state-owned asset management companies and Zhengzhou Investment Holdings Limited jointly made, mainly engaged in flat panel display and solar industry design materials, manufacturing and sales operations. Sunrise Optoelectronics project has been put into a production line, the second phase will continue the expansion, three new production lines to meet the production needs of Project Phase II, Sunrise Optoelectronics urgent need to increase new boiler equipment. After investigation and screening of a number of boiler brands, determined to cooperate with the fast boiler, steam signed a 10-ton integrated condensing gas 4 ton oil fired steam boiler (WNS10-1.25-Y.Q).

Recently, many users of the phone does not know how to shutdown after the 4 ton oil fired steam boiler maintenance, boiler maintenance is very simple in fact, today we explain the steam boiler and hot water boiler shutdown after: After the steam boiler maintenance shutdown method how maintenance. Since the cause of boiler failure or power shutdown required boiler, a steam boiler before travel should stop combustion boiler, the boiler slowly lowering the temperature until no pressure boiler, should pump before shutdown, induced draft fan and turn off the blower. After the maintenance shutdown home for boiler, furnace divided into external corrosion and home for the pot. Pot corrosion enjoying, enjoying their home for two kinds of wet and dry selected based on the length of shutdown time. When long-term disabled boiler, furnace should be paid close attention to external corrosion problems take care of themselves. First, the boiler shutdown cooling is necessary as far as possible completely eliminate fouling and ash grate heating surface of the upper, the lower portion of the furnace. Then have to adhere to certain natural ventilation flue. Under normal conditions, should be placed to dry moisture-proof agent in the furnace, flue. The dry quicklime as used, the furnace or the flue gas per cubic meter of ordinary should be placed about 3kg. After placing all the ventilation should be tightly closed doors. Lime powder to change after change. Such as boiler rooms in low-lying position, the air during shutdown severe flood tide, the method should be used regularly and placed a small fire to dry dry agent phase separation. If the boiler boiler long time, in order to thoroughly clean the soot topcoat red lead oil furnace or other metal surfaces in the anti-corrosion paint. As for the way home for corrosion inside the furnace shutdown, the shutdown Yaoan the length of time to be. Under normal circumstances, no more than one month shutdown of the available wet home for a month or more should take care of themselves dry. Dry to pay attention when enjoying the following questions: Do not dry agent in direct contact with the metal outer boiler, can be housed in a container such as an iron plate; dry agent after standing, for shutting the hole and the other hand hole cover, the vapor, the water pipe necessary to cut off valve; variant lime powder should be replaced. While enjoying wet, to pay attention to boiler water condensate is preferably used, followed by the available existing boiler water, demineralized water again; after adding the base, with a slow fire boiler water is heated to 80 [deg.] C to 100 the pressure rose to 0.2 maintenance after 0.3MPa 2 to 3 hours, so that it reaches the furnace circulating water alkalinity balance, pressure is reduced, then fill the boiler water, a certain gauge, and continue to adhere to this pressure throughout the home for alkalinity should be regularly tests, decreases should be added at any time; in winter, wet enjoying pay attention to antifreeze, especially the local sewage channel and economizer; before re-use should release all the pot boiler lye, best prepared sump, in order to facilitate further use. At the same time should be rinsed with clean water. The performance characteristics of coal, oil, gas steam boiler

Category Description oil-fired boiler fuel gas-fired boiler is different from coal-fired boilers, which requires the use of a burner fuel is injected into the boiler furnace using a combustion chamber without the use of fire grate facilities. Because not produce fuel ash after burning fuel gas-fired boiler, fuel gas-fired boiler so without slagging facilities. If the hydrocarbon injected into the furnace with the air mixing within a certain range, or turned off, it is easy to explode. Therefore, fuel gas-fired boiler combustion required to adopt automation and control systems. Fuel gas boiler compact, small boiler and ventilation, water supply, control and auxiliary equipment are arranged on a chassis, the assembly may also be medium-sized factory. Boiling water boiler fuel oil boiler fuel, also known as water heaters, stove oil, furnace fuel tea, water boiler fuel, is living in a boiler, belong to the category of civilian atmospheric boiler. The boiler is a fuel oil as fuel by a burner to heat the water, when the water temperature reaches the set temperature (water), the burner stops working, heat boiler into the automatic state, the user starts to provide water, oil and water if the boiler holding tanks connected to meet like hospitals, schools and other centralized water supply demand type units. Hot water boiler fuel oil hot water boiler fuel refers to fuel have mainly boiler fuel hot water boiler with a high-tech automatic control system, with a number of security devices, water protection, overpressure protection, flame protection abnormal pressure protection, over-temperature protection flue; using high-tech structures, having a body holding a small, compact and easy to install, simple operation, automatic adjustment, the pressurized fuel to the atomizer, and then allowed a slight positive pressure fuel combustion burner more fully, to reduce the loss of gas emissions and fuel, it is a modern industrial steam to use the most convenient and most energy-efficient, environmentally friendly standard products. Fuel 4 ton oil fired steam boiler fuel (gas) steam boiler, a horizontal combustion all wet back, efficient threaded pipe, with a sound insulation outsourcing design, the boiler thermal efficiency as high as 85% or more, product design, rational structure, process performance is good, so that this product has extraordinary excellent quality.

Other Products