3Th Oil Fired Steam Boiler Company


3Th Oil Fired Steam Boiler Company

Gas condensing boiler Gas condensing boiler Products That condensing gas boiler, the key lies in condensing technology, is a new, energy-saving and environmental protection boiler. By condensing gas boiler flue gas condensing boiler means the exhaust gas temperature can be reduced to 50 ~ 70 ℃, full recovery of the latent heat sensible heat of flue gas and steam, the highest thermal efficiency of the boiler up to 102%. Gas condensing boiler uses condensing gas boiler products can be widely used in hotels, schools, hospitals, textile mills, cafeterias, restaurants, food plants, pharmaceutical plants, packaging plants, building materials factory, swimming pool and other enterprises place. Advantages of gas condensing boiler 1, one-piece design condensing boiler boiler efficiency compared to more ordinary, more environmentally friendly. 2, a condenser and an economizer disposed tail, achieved using a flue gas waste heat step, fully absorbed the heat in the flue gas; high heat transfer coefficient of the threaded pipe, the effect of convective heat strengthening, boiler efficiency up to 102% . 3, classic three return, all wet back structure: low resistance, high efficiency. 4, all-furnace corrugated furnace structure, strengthen the disturbance smoke while increasing the radiative heat transfer area; increase rigidity furnace, effective to attenuate the expansion stress of the furnace, and long service life; enhanced heat transfer, the combustion of fuel more fully. 5, a large volume of the combustion chamber design, fuel adaptability, and can be fully adapted to a variety of city fuel gas, natural gas, light diesel oil and heavy oil. 6, positive pressure combustion, fuel combustion, less smoke emissions, are in line with national emission standards. 7, using the first all-welded and then pre-expanding, then Expansion of advanced technology, high quality welding, testing 100% pass rate. 8, Germany Germany Weishaupt burner, Olin Finland, Italy Riyadh Road, Germany Paterson and other well-known international brands burner. 9, condensing unit, outstanding economic performance, the lowest in the province 60,000 yuan. Product Structure gas condensing boiler using condensing gas boiler wet back three return, full corrugated furnace, threaded pipe structure, large volume of the combustion chamber is provided, the combustion more fully; tail saving additional condensing means, which can effectively absorb heat generated by the fuel, improve the thermal efficiency of the boiler, reducing input costs and reduce pollutant emissions. Advantages condensing gas boiler 1, a high thermal efficiency: economizer, the boiler and condenser integrated structure, sufficiently absorb heat and smoke emission latent heat of vaporization, high thermal efficiency more than 10% than the average furnace; 2, the exhaust gas temperature is low: energy , a condenser, a three-dimensional design, efficient heat transfer, corrosion-resistant materials, the exhaust gas temperature up to 60-90 ℃; 3, energy saving, environmental protection: flue rotary combustion technology, full fuel combustion furnace with ordinary than about 10% fuel savings, harmful gas emissions to the national standards; 4, high quality silicate insulation material and double sealing structure, thermal insulation, good sealing performance.

Pressure fire operations and precautions Henan fast boiler's 3th fired steam boiler company Xiao Bian told you about the operation of steam boilers and pressure fire precautions and stainless steel high temperature magnetic pump structural characteristics 1. pressure steam boiler fire steps of (1) to reduce boiler load, according to the length of time of shutdown, the seam thicker, the thickness is generally not more than 200 mm, suitable to accelerate the speed of the grate. (2) to the slag is thickened seam about 1 mm from the stop grate rotation, the drum is stopped, the operation of the induced draft fan, blowing off a small segment of the regulating plate stopper and dampers qs, relying on natural ventilation to maintain coal the lean-burn, the sewage, boiler water level will rise to the maximum allowable level. If the fire burn coal gate, grate can be switched on again, the coal-fired back, a distance. (3) the recovery boiler needs to run, as long as the opening lead, a blower, to adjust the smoke, and the wind baffle plenum segment adjusting the opening degree of the shutter, the adjustment of combustion steam boiler seam thickness to be normal, start grate, can be restored run. 2. Note the use of a steam boiler (1) before starting Check power supply voltage, there are unusual circumstances water, close the drain valve opens the water supply valve, check whether the pump stuck, stuck if the pump, remove the fan cover, rotation of the motor shaft to the flexible state to boot. (2) When the steam boiler maintenance or replacement of parts, turn off the power to avoid live work dangerous. (3) electronic control box, pump motors and other parts should avoid damp water to prevent burning boiler should pay attention to keep clean. (4) steam boilers in accordance with quality requirements, when using the apparatus sure to install a water softener, the water softener is not used because the boiler may cause fouling, may cause serious squib, shortening the life of the boiler. (5) Please note that when using sewage. And at least once a day with a discharge pressure of between 0.1MPa to 0.15MPa discharge may be prevented clogging of pipes, sewage should be properly connected, to guard against burns. Stainless steel high temperature magnetic pump structural features: a sliding bearing magnetic pump sliding bearing materials impregnated graphite, PTFE and engineering ceramics. Because of engineering ceramics has good heat resistance, corrosion resistance, abrasion performance, so the sliding bearing magnetic pump more use of engineering ceramics production. Because of engineering ceramics are brittle and expansion coefficient, so the bearing clearance is not too small, so as not to hold the shaft accident. Since the magnetic pump in order to lubricate sliding bearing medium conveyed, it should be used depending on the medium and conditions, making use of different materials bearing. 2. Cooling lubricating fluid flow control pump operation must be flush cooling internal friction annulus region between the sliding bearing and the magnetic rotor and the containment shell with a small amount of liquid. Coolant flow rate is typically 2-3% of the design flow of the pump, the annulus area between the inner magnetic rotor of the eddy current generated spacer bush high heat. When enough cooling lubricant or flushing holes poor, clogging, the medium will result in a temperature above the operating temperature of the permanent magnet, the inner magnetic rotor gradually loses its magnetism, the magnetic force actuator failure. When the medium is water or water-based liquid, the temperature rise can be maintained in the annulus region of 3-5 deg.] C; or when the medium is a hydrocarbon oil, allows the annulus region of the temperature was maintained at 5-8 ℃. Henan is committed to fast boiler steam boiler manufacturing, product quality, reasonable prices and widespread industry praise, if you have any needs, please contact us!

When the gas 3th fired steam boiler company installation is complete, you should first check whether the internal boiler tidy and clean without foreign body, and then close the manholes and valves. Oil (gas) pipeline, and the return line of compressed air to blow the pig debris, and then connect the burner fuel supply port, check the connection is tight, then a predetermined pressure test.

We learned from Anshan City Bureau of the ecological environment: to improve air quality living environment for urban residents, according to government requirements, Anshan external publicity of the built-up areas and industrial parks and a list of more than 10 tons of coal-fired boilers, municipal environmental protection department also welcome all citizens supervision, to provide the city's built-up areas and 10 tons and above boiler clues industrial park outside the list.

Battle to lay the blue sky, the city has in recent years embarked on a built-up area and the city's industrial park and 10 tons of coal-fired boilers out of work, the city built-up areas and industrial parks and 10 tons of coal-fired boilers demolition of all the reservation coal-fired boilers to achieve discharge standards. As requested, before the end of 2020 in the city of Anshan City will be built-up areas and industrial parks all phase-out over 10-20 tons coal-fired boilers, coal-fired boiler units involved should be prepared in advance.

To further enhance the quality of atmospheric environment, promote environmental management to raise the overall level, in accordance with the requirements of the provincial government, the city of the city within built-up areas and industrial parks and more than 10 tons of coal-fired boilers information for publicity. These publicity boiler will be included in the list of key sewage units, strict supervision, to ensure the discharge standards.

Other Products