2Ton Or Hr Oil Fired Steam Boiler


2Ton Or Hr Oil Fired Steam Boiler

Gas-fired 2ton or hr fired steam boiler will need to follow those steps: Due to the special nature of dual-use oil and gas boilers, thereby preparing the initial installation and construction from its long-term project to the acceptance stage there will be any problem to pay attention to the need to comply with, what does? Gas-fired steam boiler needs to follow the procedure step by step to complete. In this process, the need to comply with, what does? Boiler installation and construction of oil and gas dual front, first in accordance with the procedures to handle boiler installation approval procedures, pending approval of Quality and Technical Supervision after!

How to deal with water shortage in electric 2ton or hr fired steam boiler machine in use for some time this or that problem will be serious delays in the progress of work, causing great inconvenience to the people, such as water shortage, this problem arises in the use of electric steam boilers after a period of water shortage in how people deal with how to solve it. Electric steam boiler how to deal with water shortages: water level proofread each water level indicated by the right to judge whether the electric steam boiler water. In the electric boiler can not be determined when full of water or water vapor, can turn on the water faucet open water level, water flows out of the pot if not, indicating that water scarcity is an accident, otherwise it is full of water accidents. For the embodiment allows a small electric steam boiler waters operation, water may be called first, determines the electric steam boiler is mild or severe water shortage. This only applies to the water level gauge water hole communicating tube heating surface is higher than the highest water capacity and fire community large electric steam boiler. Otherwise it can not be called electric steam boiler water, because it will delay the time of the incident electric steam boiler water treatment, the worsening of the situation. When a slight electric steam boiler water, should reduce the fuel and air, the combustion decreased, and electric steam boiler feed water slowly to the normal level. Typically by adjusting a valve opening degree and the size, to control water flow rate and water, being careful not excess water. To quickly identify the cause of water shortage in the water and remove the process, and then check the electric steam boilers there is no unusual circumstances, after confirmation by the normal operation can resume electric steam boilers. When electric steam boilers severe water shortages, the need for emergency fire fighting shutdown. The fire shutdown procedures according to the method of implementation of the emergency shutdown, is strictly prohibited water to the pot and when serious water shortages. Some fireman personnel after the discovery of electric steam boiler water shortages, interrupted several times with water, each time a small amount of water replenishment way to cover up the accident electric steam boilers. This practice is very dangerous. If electric steam boilers are also less severe water shortage will cause biomass boiler leaks. If electric steam boiler water can cause serious electric steam boiler explosion. Only natural ventilation and cooling in electric steam boiler pot temperature dropped to below 70 ℃, water only slowly. Electric steam boiler for the water to normal level after thorough examination, no abnormal situation in order to re-start ignition, electric steam boilers to resume operation. Traditional old-fashioned coal-fired boiler using coal, gas, fuel oil and other fuel, these fuels are non-reusable primary energy, the future price will be higher. And the shortcomings of the traditional old-fashioned coal-fired heating methods are also caused by incomplete combustion, incomplete combustion can cause a lot of heat from the flue gas discharge out together, so it will cause energy losses. Boiler not only save electricity, but also saves time and effort, not the traditional coal-fired boiler heating boiler released by carbon dioxide, toxic gases, dust and other harmful substances, so users do not need to clean up, so it can save a large sum of maintenance cost.

First Affiliated Hospital of Bengbu Medical College, responsible for staff to feedback to our company, this boiler to use less smoke production, in line with the special requirements of the hospital surroundings and national requirements for flue gas emissions. During the boiler installation and operation, square quick technical staff also always concerned about the dynamic boiler, parties can feel really real fast customer service, using fast boiler is assured. --customer feedback

1: Steam boiler steam pressure the higher the better selection pressure, depending on the user's requirements. Vapor pressure, safety pressure member Advantageously, the energy consumption is low; but the steam will be relatively worse quality, low enthalpy, humidity, may be difficult to meet the disinfection, sterilization, culture, heating and power needs. And the high vapor pressure, energy consumption is high, the corresponding steam equipment, piping and valves the pressure is high, the maintenance requirements are also more, the production of steam, the heat transfer process, a large leakage loss. Meanwhile, high-pressure steam as the steam pressure is increased to carry the increased salinity, so salinity these waterwall tubes, pipe tobacco, and other drum heating surface fouling, overheating, foaming, clogging even increase the possibility of squib. Salt steam to steam turbine flow area will decrease, reducing the efficiency and seriously affect the heat transfer. Thus, fireman must operate in accordance with operation of the steam pressure, the steam pressure fluctuations generally allows a value between 0.05 ~ 0.15MPa.

2: the higher the boiler water level was considered safe water level is higher, the boiler water is not easy, security is also guaranteed. In fact, this is a misconception, the water level is too high, steam and humidity increase, poor steam quality, steam equipment will harm and production results. Industrial boilers, a moisture vapor sterilization or incubation with a large amount of steam also increased salt, or culture for a long time ranging from sterilization, steam consumption increase, ineffective, decreased production culture; weight is not reached the purpose of disinfection or cultured biological products contaminated scrap, even pipes, water hammer occurs apparatus. For utility boilers, steam moisture capacity, the steam turbine last stage blades will be erosion, there may appear Priming pot, water shock severe enough to cause harm equipment and personal safety. Thus, the pot water level should be maintained within a fluctuation range of ± 50mm well.

3: Some people think the better fuel plus fuel plus the more productive the greater the amount of steam. Little do they know too much fuel into the furnace, the effect will be counterproductive. When a certain amount of air and the excess amount of fuel, the furnace will produce a large amount of incomplete combustion, resulting in energy waste. People often see the dark furnace flame, weakness, and black smoke chimney, mostly for this reason. In severe cases, there will be fire pulverized coal, oil furnace secondary combustion occurs, burst pipes until shutdown. Therefore, the ratio of fuel and air volume should be adjusted appropriately, typically by looking at the fire, smoke color look, see table indicates the amount of oxygen determined. When the flame in the furnace as a bright yellow, pale gray smoke chimney to take, stable vapor pressure, wind coal showed appropriate ratio, good combustion.

4: Dial stirring the fire, the better the fire is commonly used in industrial boilers manual method. By stirring the fire, can be eliminated crater, reduction furnace from the fire and the fire bed smooth, homogeneous combustion, strong. But too much stirring the fire, but will reduce the overall thermal efficiency; this is because when stirring the fire, a lot of cold air into the furnace, reducing the average temperature of the furnace section of the flame. At the same time, increase the heat losses, an increase in the number of black smoke chimney, pollution of the environment. In addition, when stirring the fire, the staff is also susceptible to flame radiation, burns, fire-resistant layer is also susceptible to dial hearth fire damaged tools, increased furnace building maintenance workload. Therefore, the fire should be allocated as needed, to minimize the appropriate dial.

5: the bigger the better furnace pressure and furnace pressure is reflected in one of the boiler combustion conditions is normal or not an important parameter. Operating the boiler furnace negative pressure should be maintained between 10 ~ 20Pa, too great a negative pressure results in: increased leakage furnace, heat losses increase; wind increased electrical energy consumption; fly ash increased the wear along the heating surface; reduced the furnace heat of combustion efficiency. Most gas-fired boiler designed to run slightly positive pressure to increase the combustion rate. Operation, the furnace pressure becomes positive, even increasing the wind is still difficult to maintain the chamber negative pressure, said system failure or the wind furnace wall tubes, superheaters and other soft drinks leakage; fire furnace, the furnace pressure is first reflected table violent swing to the negative direction flung head. Therefore, the furnace pressure must be run according to the provisions, or should pinpoint the cause.

6: sewage longer the better spoken here regularly refers only to the sewage discharge rather than continuous blowdown. Periodic sewage mainly refers to the existence of negative bottom of the boiler slag, dirt and corrosion products, reduce furnace tube fouling, prevent clogging and reduce the salt content of the water boiler, heat transfer enhancement effect. One would think that the longer the discharge time, impurities will be discharged bottom of the pot the more, the better sewage, it is not. Sewage long time, a waste of a lot of heat, affect heating steam pressure; two pairs of boiler water circulation unfavorable, water wall tube burst will occur in severe cases. Thus, the sewage must be periodically according to "ground discharge, the discharge less uniform row" principle, provided hand operation. General Provisions at least once every eight hours of sewage, sewage each time shall not exceed 30s, overtime is strictly prohibited.

Other Products