20 Th Natural Gas Steam Boiler


20 Th Natural Gas Steam Boiler

"Can shipped on time, not only the ability to schedule Tianjin coal-fired boiler project and the Tianjin Municipal People spend time heating, but also on our fast boiler brand image, so we have to work overtime quality and quantity the coal-fired boiler complete product supply mission. "fast square to official said. Facing short construction period, heavy task difficult, we rationalize production processes, all front-line staff hard working, eventually will be shipped on time to the boiler Tianjin, and running. After the boiler in place, Tianjin coal-fired boiler project also completed the basic preparation, coal-fired boilers, Tianjin is also a blue sky will gradually improve and advance. Tianjin transformation of coal-fired boilers, fast Boiler contributed.

Gas boiler szs 1 emergency shutdown procedures, if necessary emergency shutdown generally, when the boiler encounters one of the following, operation should be stopped in case of emergency; (1) allow the boiler steam pressure exceeds a safe pressure, fueling is stopped strengthen water supply, measures the wind pressure continues to rise. (2) boiler severe water shortages. Water meter can not see the water level. After being called water, the water level of sight. (3) When the severe water boilers, boiler water level is higher than the highest water level is visible, but the emission level not yet seen. (4) increase in boiler water, take other measures, the water level will continue to decline. (5) water supply device is turned off, standby equipment. (6) all water level gauge or invalid. (7) All the safety valve all the failures. (8) All all-off failure drain valve. (9) causing damage to the boiler pressure element (e.g., boiler tubes, etc.), or endanger the safety of the device. (10) boiler is a serious threat to other events and safety equipment. 2, natural gas boiler operation method szs immediate emergency stop operation of the controller, the boiler is off, closing the front of the boiler gas valve to stop the gas supply. The 20 th steam boiler competent completely separated, opening the exhaust air valve or safety valve steam pressure. Due to lack of water, the boiler is not allowed into the boiler, the steam is not discharged to reduce pressure. No shortage of water, cold water can drain down alternate method, the water level remains complete accident should immediately stop the water supply, water reducing combustion (fire artificially changed into a small fire), play an open valve while opening the main steam pipe and the drain valve cylinder to prevent the steam to carry large amounts of water, water. In the shutdown process, the cooling rate of the furnace should not be too fast to avoid flue compression member and the expander is damaged suddenly cooled. 3, emergency shutdown processing method szs natural gas boiler in the case of emergency shutdown, due to the nature of the accident, the following may take a different approach: (1) rapid flame treatment emergency shutdown, the burner first station, and closing the valve flame gas supply is stopped after the cut valve, to maintain the water level is normal. (2) rapidly cooling the furnace or water if there is no water leakage during an emergency stop, the cooling time can be shortened to the boiler water and sanitation and reduce the pressure. When the boiler water temperature down to 80 degrees Celsius, boiler water can be discharged. If the boiler severe water shortages, the boiler can not cool quickly in the event of an outage. Non-water to the furnace, or explode. accident. (B) natural gas boiler shutdown SZS normal shutdown (complete shutdown, shutdown maintenance) procedures which can be used when needed repair or stop steam boiler. 1. If one of these faults, the leaders agreed, the boiler can be temporarily closed repair: bilge faucets, riveted joints leak, damaged tubes, the waterwall tubes, the heating tube, the flue gas contacts the drum, the head, off pipe insulation, water supply system, combustion system, a serious fail-safe accessories, in need of repair. 2, a temporary repair (or normal shutdown) the method of operation in order to stop the burner, for closing the valve. Boiler feed water to 2cm above the normal water level, to stop water supply, reduce the pressure. 3. Turn the main steam valve, open the traps, and steam boiler operation, reliable water separator. 4, boiler feed water close electric valve and manual valve, boiler feedwater reliable cutting. When the steam pressure drops to zero, the water can be supplied and discharged alternately, so that water is gradually cooled furnace, when the temperature drops to 50 degrees Celsius (or hand potshell touch feeling hot pan head), can be completely discharging furnace boiler water water . Before water, open the air valve on the boiler or lift safety valve. At this point, you can enter the furnace for inspection and repair. Cooling the furnace must be kept slow, non-violent cooling and damage to the boiler, the boiler can be stopped from the repair into the furnace, the cooling time is generally less than 24 hours. Close the furnace over 24 hours, shut off the gas supply valve at the regulator, and open the gas conduit pipe is responsible, in the exhaust gas pipeline.

Preparation and method for measuring the moisture content of the flue gas of the boiler before the boiler purchase this product knowledge and understanding, the present, it is necessary for two reasons, first, it is the site of important product and the main key one word, and second, the products are widely used, why we have these conclusions and specific requirements. Meanwhile, I hope that we can be taken seriously and, in order to have learned well and apply their knowledge to practical work flexibly. Is there some preparatory work before the boiler 1. buy? Boiler products to buy, this is an important job, and need to be taken seriously, but also want to take into account all relevant factors, in order to have accurate judgments and the correct choice, a good choice to avoid mistakes. Before carrying out this work, is the need to do some preparation, use of the product to the environment and have a clear understanding of the requirements and learn about product origin, specifications, technical parameters, materials, quality, price, service and product manufacturers these and other basic information, in order to compare and consider, then, the right to choose their own products. 2. whether Sheung Shui before the boiler starts have specific requirements? From a professional point of view, Sheung Shui before the boiler starts, there are some basic requirements, which specifically is: If the hot water boiler, the water speed before it starts not too fast, not be less than the winter time Sheung Shui 4 hours, in other seasons upper water time of not less than 2-3 hours. And, at the beginning of the water, its water speed to slow. If the boiler is cold, it's inlet temperature in the range of 50 ℃ -90 ℃, and the difference between the water temperature and the temperature of the drum wall into the steam drum, not greater than 40 ℃. 3. What is the chain boiler? Chain boiler, which is a particular kind of a boiler, a higher degree of mechanization layers fired boilers, the time the track grate with a chain similar to these so called chain boiler A boiler. Further, it is a pre-boiler, the coal combustion process is completed in the movement. Advantage of this kind of boiler, the combustion condition is stable, high thermal efficiency and easy operation, in addition, its low concentration of dust emissions. However, it should be noted that the moisture content of the larger, more ash and strong coking coal, not suitable for this kind of boiler for combustion. 4. How the moisture content in the flue gas boiler measured? Determination of moisture content in the boiler flue gas, which is the weight measurement method, condensation method, and three psychrometer, and the moisture content of the flue gas is typically in the volume percent of water vapor in the flue gas content to represent. If dark gravimetry, need to use hygroscopic agent, the hygroscopic agent used is calcium chloride, calcium oxide, silica gel, alumina, phosphorus pentoxide, magnesium perchlorate and the like.

Improve the thermal efficiency of gas 20 th steam boiler steam boiler to improve the thermal efficiency of gas is a problem many users are taken, I believe this issue is the direction of each used in the production of various types of gas steam boiler manufacturers have been in the study. Many users at the time of the gas-steam oven operates, often in the actual production process, we found some new problems, but all the problems, the most vexing is the high temperature exhaust gas steam boilers, thermal efficiency than low phenomenon that a serious impact on our work, then how should we do to improve the thermal efficiency of it? need to know this is the best way to meet the low-temperature properties of gas and steam comes as synthetic gas steam. However, the vast majority of synthetic gas and steam biphenyls, benzene derivatives of both components of the complex, or a vapor of volatiles has strong carcinogenicity, it is strongly recommended that the client select the type of mineral oil vapor product gas. Second, gas and steam products to meet the low temperature performance process, but also have a relatively high flash point required. In general, gas steam engineers suggest, low temperature gas steam flash point not lower than the opening 200 ℃. After a professional manufacturer of continuous research and improvement of its equipment, in order to improve its thermal efficiency was found to be increased tail gas steam boiler heating surface of, say, air preheater and economizer. But when organic heat carrier furnace return temperature is high, you can not set the economizer, air preheater can only be set to alleviate the situation. So if no gas steam boiler and other heating systems for low temperature heat exchanger, then the only way to improve the energy efficiency is adding air preheater. After adding air preheater can be a corresponding increase in gas flow rate of steam, gas steam boiler in order to ensure safe, reliable and stable work, the thermal efficiency of gas-steam boiler plant will be a corresponding with the increase.

Other Products