1T Oil Fired Steam Boiler


1T Oil Fired Steam Boiler

Oil-fired boilers include oil-fired water boilers, oil-fired hot water boilers, oil-fired heating boilers, oil-fired bath boilers, oil-fired 1t fired steam boilers and so on. Oil-fired boilers are boilers fueled by light oil (such as diesel oil, kerosene), heavy oil, residual oil or crude oil. Oil-fired boiler, gas-fired boiler, electric heating boiler is more economical than electric heating boiler and more convenient to use than gas-fired boiler compared with vertical oil-fired hot-water boiler.

Principles of 1t fired steam boilers and solutions hydraulic external gear: told you about the principles of steam boilers and solutions for steam boiler hydraulic external gear in accordance with the fuel (electricity, oil, gas) can be divided into electric steam boilers, oil steam boiler, gas steam boiler three kinds; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler compact than a single, double return of the vertical structure, a large steam boiler plurality of three-pass horizontal structure. If the classification according to top standards, in the form of steam boilers on the lot, would like to give an ordinary packaged boiler say four tons vapor. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Steam boiler combustion section and drive means by a chain grate, a combustion chamber together with the pan rack frame formed on a grate composition. Four weeks envelope refractories.

Due to the special nature of the industrial park location, we are more to consider whether the boiler with green features in the choice of boiler equipment. According to our survey of the entire boiler industry, quick side has considerable experience in research and development in the field of environmental cleaning boilers, boiler equipment while also providing low pollutant emissions for Beijing more enterprises and institutions, we are fully confident that the fast boiler ability. --customer feedback

Gas boiler safe operating procedures: gas-fired boilers this kitchen I believe we are not unfamiliar fishes it. But this thing is not so easy, and sometimes improper operation causing very serious consequences, so the gas boiler rules is very important. That in the end this is how the specific operation of it, if you want to know, quickly told us with a look. 1. All personnel must be familiar with the operation of the boiler performance and safety knowledge of the boiler operating certificates. This post is strictly prohibited non-operating personnel. Duty should be strictly in accordance with the operating records and do a good job shift recording, the security situation and the device should shift change operation tests, carried out. When the shift to check the boiler is intact. 2. Boilers and safety accessories should be inspected, and in the period. 3. Kai blast furnace gas furnace ready ① Check if the gas pressure is normal, not too high or too low, open the door of oil and gas supply section; ② Check whether the pump Sheung Shui, or opening the purge valve, until the Sheung Shui so far. Open the Water Supply System for each section of the door (front door section Sheung including pumps and boilers); ③ check level gauge, the water level should be in the normal position, the water level gauge, a water level required color plug in the open position, the water level to prevent false, if water can be manually Sheung; ④ check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob ⑤ checks the control cabinet are in their normal position; ⑥ 1t fired steam boiler check valve should be in the closed state hot water boiler circulating pump outlet valve should be turned off; ⑦ checking water softening equipment is operating properly, a variety of indicators to create a soft water meets national standards. Open the power ⑴; ⑵ startup burner; ⑶ purge valve on the drum, is completely out of steam, the off; ⑷ inspection hole into the boiler, and the hand hole flange valves, the leak was found to be fastened, tight as the solid leakage maintenance shutdown; ⑸ pressure rise when 0.05 ~ 0.1MPA, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; ⑹ when the pressure was raised to 0.1 ~ 0.15MPA, flushing pressure gauge trap; ⑺ when the pressure was raised to 0.3MPA, "fire load / small fire" knob to "fire" to strengthen the combustion; ⑻ when the pressure was raised to 2/3 of the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; ⑼ drain valve is completely closed out of steam; ⑽ after all the drain valve closed, slowly open the main valve to open, and then half a turn; ⑾ "burner control" knob to " Auto "; ⑿ level adjustment: adjusting the water level (to manually start and stop the pump) according to a load, low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; ⒀ steam pressure adjustment: adjusted according to a load combustion (manual adjustment Fire / small fire) ⒁ combustion state determination, determines the amount of fuel atomization air ⒂ observation condition exhaust gas temperature, smoke, temperature control is generally between 220--250 ℃ The flame color, smoke color, while observing the chimney exhaust gas temperature , concentration, adjusted to the optimum combustion state. ⑴ Open the power; ⑵ start the circulation pump; ⑶ slow circulation pump outlet valve; ⑷ startup burner; ⑸15 min "" Load fire / small fire "bit color button is turned to" fire "" ⑹ "burner control" knob spin to "automatic." 5A normal shutdown: hot water boiler ① "fire load / small fire" knob to "small fire"; ② off the burner; ③ close the fuel supply valve; ④ ⑤ closing dampers boiler after the temperature dropped to 50 ℃ , the circulation pump outlet valve closed. ⑥ stop circulation pump

Other Products