150 Psi Oil Fired Steam Boilers


150 Psi Oil Fired Steam Boilers

Boiler water treatment analysis of safety issues: the problem of boiler water treatment is an important part of the process of the safe use of boilers in general we all know that the market is now using more coal-fired 150 psi fired steam boilers, steam boiler fuel ratio or gas accounts for a large steam boiler most, especially in the current market share of imports of fuel gas-fired boiler in the market constantly rising, mainly due to fuel gas-fired boiler of compact, small size, high water quality requirements, at the same time, due to the oil and gas combustion temperature itself relatively high, therefore, be able to do is very important for boiler water treatment, boiler water treatment, if done well it will cause boiler fouling, corrosion, which not only wastes fuel and it can lead to blocked pipes, burst pipes and other accidents, and more there will also be scrapped boiler caused severe economic losses ***. Therefore, fuel oil and natural gas boilers must strictly check boiler water treatment problem seriously.

Behind honor, it is thousands of times persist and exploration. Keep trying, and failed to improve, we have a number of scientific and technological problems. The launch of China's first low nitrogen boiler and stable operation in 2014, Beijing Huairou APEC venue for the realization of "APEC blue" to contribute their part. Respond positively to national policy, contribute to the cause of environmental protection. Group focus on lower nitrogen oxide emissions, a low nitrogen introduction of multi-type boiler. Existing "Thalia", "Willie sharp" and other series, the successful implementation of nitrogen oxide emissions below 18 mg / cubic meter, this data is far below the national existing standards (such as the most stringent in Beijing the implementation of 30 mg / cubic meter standard), is widely used in national important organs of the CPC Central Authority, the national Tourism Bureau.

Electric 150 psi fired steam boilers steam boiler characteristics 1, security: 1 leakage protection: When the boiler leak, promptly cut off the power supply through leakage circuit breakers, to ensure personal safety. (2) Water protection: When the boiler water, promptly cut off the control circuit of the heating tube, heating the tube to prevent damage to dry. Meanwhile, the controller sends water alarm signal. Ground fault protection: charging the boiler housing, the leakage current through the ground line to ground is introduced to ensure personal safety. In general, to maintain good protective grounding wire connected to the metal, the depth of the underground pipe angle as grounding, the grounding resistance should not exceed 4. Steam overpressure protection: When the boiler steam pressure exceeds a set limit pressure relief valve start and release the steam to reduce the pressure. (5) The overcurrent protection: When the boiler overload (high voltage), earth leakage circuit breaker is automatically disconnected. Power Protection: With advanced electronic circuit detects over-voltage fault condition, voltage, disconnection, to provide reliable power protection. 2, to facilitate: a power supply after the introduction of the electrical control box, a key press operation, the boiler will enter (or leave) the automatic running. (2) reducing the water boiler, the control system will automatically replenish the water tank to the boiler through a replenishment pump. 3. rationality: In order to reasonably effectively utilize electric energy, in particular the heating power divided into several parts, automatic cycle input by the controller (cutting) the heating power according to a user's actual needs, just close leakage breaker ( or press the corresponding switch) can. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Heating pipe segment switching cycle reduces the impact on the grid of the boiler in operation. 4. Reliability: a bottom of the boiler furnace using arc welding, manual welding surface of the furnace cover, and the furnace strict X-ray detection. (2) boiler steel production in strict accordance with the standard selection. (3) boiler accessories selected domestic and international high-quality products, and the boilers were tested in order to ensure long-term normal operation of the boiler. Oil (gas) steam boiler steam boiler 1. Gas burner provided by the well-known manufacturers in the world. According to a command of the controller, the automatic combustion stop, the program controller having a plurality of independent security protection, security and stability performance, low maintenance. 2, the controller automatically advanced steam boilers, Chinese LCD display, man-machine interface, the user simply easily set, according to user requirements the boiler can start and stop, load adjustment, automatic water supply automatic operation. The boiler fully functional, complete protection, simple operation, safe and reliable, has a self-diagnostic function. Once the boiler operation anomalies occur, it will automatically interrupt burn, concurrent sound and light alarm. 3. Zhuoyi Li steam boiler burner shutdown mode, two circuit configuration, fuel combustion, boiler stable; flue insert spoiler, smoke slow speed, increasing the heat transfer, high thermal efficiency, reduced user cost. 4. The steam boiler is a horizontal shell-and refluxed for three full moisture pyrotechnic reflux pipe structure, not only improves the strength of the heat absorption of the boiler, but also meet the needs of the expanded heat transfer surface, a scientific and rational. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Durable.

Construction of gas 150 psi fired steam boilers steam requirements for the construction of a gas boiler requirements, gas steam boiler installation for the construction of the boiler room have certain requirements, must comply with national requirements in the construction process. Gas and steam 1, the construction of a gas steam boiler room requirements 1) boiler room must comply with the "boiler energy saving technical supervision and management regulations" and "industrial boiler room design specifications" requirement. Gas steam 2) boiler room should have sufficient light and good ventilation, have the necessary antifreeze measures. And boiler room should stay away from schools, housing and densely populated areas. 3) the position should be close to the boiler room heating equipment, in order to reduce head losses and heat loss from the hot oil piping circulating pump. 2, furnace heat carrier device is arranged in claim 1) the sump should be lower than the lowest position of the heat carrier furnace and heat system 1 m, in order to put the net organic heat boilers and systems, sump and furnace heat carrier spacing less than 5 m or separated by a partition wall. It should be fitted with a sump exhaust pipe, which exhaust pipe diameter should be large and specifications than the inflation tube. 2) position of the expansion tank should be higher than the other devices and the piping system, the system must be higher than the maximum bottom level 1.5 m. It should not be installed directly above any one boiler, organic heat carrier to prevent overflow cause a fire. 3) the sump vent pipe, expansion tank, should be connected to the outdoor safety. Can not be mounted on the vent pipe to the valve, to ensure that the tank, the expansion tank to atmosphere to ensure atmospheric pressure operation. 4) the high volume of the expansion tank should be greater than 1.3 times and all the organic heat carrier furnace heat the entire heating systems is at the operating temperature is increased due to thermal expansion of volume. 5) low volume tank furnace heat carrier to be less than 1.2 times the total amount of organic heat. 6) hot oil circulation pump should be at least four weeks for 0.5 m space, and the inspection to ensure the installation routine, the need for maintenance.

Other Products