12 Tons Heavy Oil Boiler


12 Tons Heavy Oil Boiler

Dairy production and processing sectors, need a lot of steam on food drying, sterilization, stereotypes, such as processing, steam 12 tons boiler essential. Xinjiang Ake Su Xinnong Dairy Co., Ltd. as a local brand, has a large market users. 2016, Akzo increased demand for dairy production, the original steam boiler company can not meet today's production needs. In the same year, Akzo dairy cooperation with our company, signed a series SZS 6 tons of steam pipe steam boilers, steam support for the dairy industry dairy production Aksu.

Center back 12 tons boiler combustion boiler is preferably small foreign structure, although the two-pass boiler, the heated area is small, but the use of the turbulator charming, the purpose of enhancing the turbulence of the flue gas, disrupt laminar flow boundary wall, reducing the thermal resistance, increasing the heat transfer coefficient, a smaller heating area to achieve the same high thermal efficiency. Lower exhaust gas temperature limit in theory, the exhaust gas temperature can be reduced to very low or even close to the ambient temperature, for maximum thermal efficiency. However, in practice, due to the reduction of the exhaust gas temperature, low temperature corrosion will cause, therefore, the exhaust gas temperature can drop too low, in order to ensure that the wall temperature is higher than the main boiler heating surface flue gas dew point temperature. Therefore, low-temperature corrosion has become a major obstacle to reduce exhaust gas temperature and improve the thermal efficiency of the boiler. Tail auxiliary heating surface increases, further reducing the exhaust gas temperature, fuel gas boiler SZS improve thermal efficiency because the oil, gas type SZS easy to burn the fuel gas boiler air preheater generally not disposed. The economizer means is a common energy, which can be recycled flue gas was able to effectively reduce exhaust gas temperature.

PRODUCT INTRODUCTION fuel gas-fired 12 tons boiler fuel gas-fired boilers and coal-fired steam boiler is not the same, gasoline and diesel and gas-fired burner must be poured into the fuel to the boiler furnace using a combustion chamber rather than grate facilities. Since the fuel gas-fired boiler is not easy to cause the fly ash lit, so no oil or gas boiler slag removal equipment. If mixed with air or exterminate within a certain range, it is introduced into the furnace petrochemical and gas easily the explosive. Thus, any gasoline and diesel and gas-fired boilers must be selected and automatic combustion control system. Compact boiler fuel gas, and the small boiler exhaust, drainage, control and auxiliary equipment installed at the distribution panel, and produce large and small boiler assembly. Fuel gas-fired boiler safety valve installation key point describes the installation of fuel gas-fired boiler safety valve sure to carry out in accordance with reasonable installation process, to prevent wrong and lead to risk. Fuel gas-fired boiler safety valve installation should pay attention to what matters? The following is a brief description: 1 oil-fired boiler safety valve having a lever bar to avoid self-weight and the mobile device guide body defining deviant lever, the spring valve lift handle and avoid the need for screw adjustment means random twist. 2. Rated evaporation than 0.5t / h gas boiler safety valve should be arranged at least 2, Rated evaporation gas boiler should be equal to or less than 0.5t / h, fitted with at least one safety valve. Separable economizer outlet and a steam superheater outlet valve should be installed. Sectional area of ​​the connecting pipe between the boiler safety valve 3. Fuel gas boiler can not be lower than the imported cross-sectional area of ​​the valve. If several valve mounted on each stub is directly coupled to the drum, the passage sectional area of ​​the stub is less than 1.25 times not all of the area of ​​the exhaust valve. 4. Oil and gas boiler safety valve should be mounted vertically in the height of the boiler drum and the header. Can not be mounted between the valve and the steam outlet conduit and the valve drum or header. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25 mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20 mm. 6. Fuel gas boiler safety valve should normally be established an exhaust pipe, the exhaust pipe should be directly connected security grounds, and there is sufficient cross sectional area to ensure the smooth flow of the exhaust gas. The bottom of the valve should be equipped with an exhaust pipe connected to the drain of a safe place. Valve must not be installed in the exhaust pipe or drain pipe.

Construction of gas steam 12 tons boiler steam requirements for the construction of a gas boiler requirements, gas steam boiler installation for the construction of the boiler room have certain requirements, must comply with national requirements in the construction process. Gas and steam 1, the construction of a gas steam boiler room requirements 1) boiler room must comply with the "boiler energy saving technical supervision and management regulations" and "industrial boiler room design specifications" requirement. Gas steam 2) boiler room should have sufficient light and good ventilation, have the necessary antifreeze measures. And boiler room should stay away from schools, housing and densely populated areas. 3) the position should be close to the boiler room heating equipment, in order to reduce head losses and heat loss from the hot oil piping circulating pump. 2, furnace heat carrier device is arranged in claim 1) the sump should be lower than the lowest position of the heat carrier furnace and heat system 1 m, in order to put the net organic heat boilers and systems, sump and furnace heat carrier spacing less than 5 m or separated by a partition wall. It should be fitted with a sump exhaust pipe, which exhaust pipe diameter should be large and specifications than the inflation tube. 2) position of the expansion tank should be higher than the other devices and the piping system, the system must be higher than the maximum bottom level 1.5 m. It should not be installed directly above any one boiler, organic heat carrier to prevent overflow cause a fire. 3) the sump vent pipe, expansion tank, should be connected to the outdoor safety. Can not be mounted on the vent pipe to the valve, to ensure that the tank, the expansion tank to atmosphere to ensure atmospheric pressure operation. 4) the high volume of the expansion tank should be greater than 1.3 times and all the organic heat carrier furnace heat the entire heating systems is at the operating temperature is increased due to thermal expansion of volume. 5) low volume tank furnace heat carrier to be less than 1.2 times the total amount of organic heat. 6) hot oil circulation pump should be at least four weeks for 0.5 m space, and the inspection to ensure the installation routine, the need for maintenance.

Other Products