1000Kw Boiler Oil Fired Boiler For Sale


1000Kw Boiler Oil Fired Boiler For Sale

How to prevent running back pass secondary combustion 1, 30% of the rated 1000kw boiler fired boiler for sale to deal with the amount of purge air before boiler ignition; the boiler must be 30% of rated air flow purge less than 5 minutes after the boiler fire, or allowed to boiler re-ignition. 2, fine-tuning the boiler and combustion systems pulverizing system operating conditions, to prevent incomplete combustion of oil and coal accumulating on the tail heating surface or flue. 3, boiler burning oil, adjust the proper air flow, fuel flow, confirming good gun oil spray, burning completely. If you find a bad oil spray gun should be discontinued immediately, and clean up. 4, when the oil application group administered powder, cast powder should be confirmed before the oil burner ignition good, or allowed to cast powder. 5, the oil powder boiler during cofiring, and check the fuel oil gun system of fire reinforcement. 6, normal operation, operation personnel in monitoring the economizer, an air preheater flue tobacco in different conditions of temperature, abnormal, should be checked to detect a fire-place. 7, air preheater sootblowing steam system normally put into operation, the soot-blowing pressure and temperature in a predetermined range. When the unit load or less prolonged 300MW kerosene mixed combustion, air preheater sootblowing steam to be continuous. 8, the air preheater into a reliable fire alarm device. 9, an air preheater inlet and outlet fume / air damper, and should be able to put an electric shutter can be open, closed tight. 10, if found preheater stall, should be put into operation again immediately, if not turn back, they should be isolated.

Our company has been committed to using environmentally friendly, a paper manufacturing process cleaner way, so we paid great attention to environmental protection 1000kw boiler fired boiler for sales and other properties in selected product when the boiler. The fast-party cooperation and boilers, our company is the right choice to make, party fast to the products we offer very environmentally friendly characteristics, and has high efficiency, for my company save a lot of costs. --customer feedback

What differences have low nitrogen 1000kw boiler fired boiler for sale with ordinary boilers? We all know now the boiler furnace oil and gas market sell very popular, especially for low NOx combustion of furnace oil and gas is in short supply. However, for many boiler manufacturers, the low nitrogen technology is even more difficult to overcome the problem, the birth of low nitrogen boiler is a milestone, a professional low nitrogen furnace boiler developed by the company's low-NOx combustion technology has been widely used in the industrial boiler application. 1, since the difference in emission layer burning combustion mode, combustion chamber, different circulating fluidized bed boiler, the furnace in different structures, the original NOx emissions which there are large differences, in general, not specifically for low NOX combustion furnace technology employed when , circulating fluidized bed low NOx raw emissions, NOx emissions to the original furnace chain represented slightly lower layer burner, pulverized coal-fired boilers industrial boilers room, the higher the NOx emissions original, well-known low nitrogen emissions from boilers are but Greatly reduced. 2, the different layers combustion boiler technology, combustion chamber, circulating fluidized bed boiler may be different with different low NOx combustion technique in accordance with the combustion mode, the combustion boiler for the air distribution layers using an air classifier, and more often to achieve low nitrogen Gas Recirculation combustion; under typical flue gas recirculation layer influence combustion boiler combustion zone, in conjunction with the air fractionation techniques for reducing NOx by catalytic char; super reduction furnace denitration technology in recent years, new furnace denitration technology, by combustion reasonable location of the flame spray region ammonia, direct denitration at a high temperature flame. Low Nitrogen mainly the secondary air boiler, the coal to the location and distribution of optimal adjustment of the mouth, or the like to increase the flue gas recirculation system. 3, at different central security layer after combustion, combustion chamber, low-NOx combustion furnace circulating fluidized bed boiler technology a large number of tests performed, it has been verified in engineering applications, in general, a low nitrogen boiler to safety higher, the reason why in recent years, its sales volume increasing, there are many users because of its high security, a small threat to the space environment to buy, and this is one of its important differences with ordinary boilers.

How to prolong the life of the 1000kw boiler fired boiler for sale low nitrogen Now, with demand increasing in industrial production, the traditional boiler has been completely unable to meet the higher requirements of these industries, and domestic professional low nitrogen boiler manufacturing enterprises not only to bring Conveniently, they also save some costs, it is widely used in various fields, but how we should extend the life of low nitrogen boiler it? 1: Check the power to do maintenance work because of the low nitrogen boiler acts as a very important role in the production of industrial, so companies before use, you must first do a good job security and troubleshooting, power checks and maintenance work, in order to ensure users personal safety and efficient operation of the boiler, Also, the various parts of the device to check all aspects of the work, to make the life of low nitrogen boiler becomes longer. 2: the device to keep dry and regularly check the patency of the smoke tube boiler when low nitrogen after completion, the operator should be promptly cut off the power, and when the apparatus until the temperature drops, dust and dirt need to clean the housing, the boiler also placed in a dry and ventilated place, the next device in order to ensure the normally open, secondly, due to the low nitrogen boiler exhaust gas is carried out primarily by the threaded pipe, so that the operator using the device after this, smoke tube should be cleaned regularly to avoid being blocked by dust and affect their effectiveness. 3: To add a lubricant for the component devices on a regular basis when low nitrogen boiler running at low load, disk prison staff must focus on and strengthen the analysis of each instrument, abnormal should promptly make the right judgments and treatment, in order to ensure the normal operation of the boiler and to extend the life of the enterprise in order to create greater economic benefits, in addition, also for the various components of low nitrogen boiler regularly add the oil in order to reduce the resistance of boiler operation and to improve its production efficiency. All in all, in addition to the user to do routine checks and maintenance work power, we should also keep drying equipment and do regularly check smoke tube patency, to make good quality and low prices of low nitrogen boiler to have a better use effect and longer life for enterprises to win the biggest economic benefits.

Other Products