1000Kg Electric Steam Boiler


1000Kg Electric Steam Boiler

Gas boiler shutdown normal shutdown process step is one step in the process of boiler operation is essential to understand the shutdown processing methods to ensure more long-term operating life of boiler. When the boiler the following faults can temporarily shutdown for maintenance. Expansion port, leakage rivet joints; tube, the waterwall tubes, damage to the heating surface tube leakage; drum in contact with the flue gas, set top box, a heat insulating material off the downcomer; water supply system, a combustion system, the occurrence of breakage safety accessories . Shutdown of the gas boiler normal (full shutdown, maintenance shutdown) Step 1, in order to stop the burner, for closing the valve. At the same time feed water to the boiler, 2cm above the normal water level reaches the stop water supply, reduce the pressure. 2, close the main steam valve, open the traps, steam boiler, water cut off. 3, the electric boiler feed water control valve closed and the manual valve, boiler feed water cut. 4, steam pressure may be lowered to the water supply and drainage operations alternately 0, the pot water temperature is gradually lowered. When the temperature dropped to 50 ℃ (not hot when hand potshell head with or touch), the entire pot of water may be drained. Should be preceded by opening the drain valve or air valve above the boiler, this time into the furnace maintenance, shutdown must be kept slow cooling, rapid cooling is prohibited. From the shutdown to be able to enter the furnace maintenance, cooling time is not less than 24 hours. 5, sales of more than 24 shutdown, to total gas supply valve is closed, opens the gas pipe to completely drain the subjective dispensing gas.

What problems should be paid attention to in maintenance Electric normal pressure Boiler

Nowadays, advanced electric atmospheric pressure boilers need to be used in industrial production as well as in daily life. However, the electric atmospheric pressure boiler is a highly operational mechatronics equipment, such as customer inspection, maintenance is not timely will result in equipment line aging, equipment oil circuit and oil pump wear and so on. Therefore, users need to pay attention to the maintenance of equipment when running boilers, then, what problems should users pay attention to in the maintenance of electric pressure boilers with good performance?

1, pay attention to stop furnace detection electric atmospheric pressure boiler in the maintenance, users should let the equipment according to the normal shutdown procedure operation to achieve slow cooling, at the same time, Users should use pot water circulation and furnace ventilation to gradually reduce the temperature in the pot and furnace. It is worth noting that when opening the door hole of the equipment, users need to pay attention to preventing the burning of steam, hot water and flue gas in the boiler.

2, note that when users maintain the insulation, the combustor and flue of the detected atmospheric pressure boiler should be separated from the total flue or the other running boiler flue. The test results are as follows: (1) the combustor and flue of the tested atmospheric pressure boiler should be separated from the main flue or other running boiler. And the flue gate should be closed tightly, and in the partition after ventilation. In addition, the blind plate used in equipment partition should have sufficient strength and hardness to avoid being bulged by high pressure medium in the operation of electric normal pressure boiler, and the partition position should be clearly indicated to avoid confusion.

3, note that the user must completely cut off the connection pipe between the vessel and the gas equipment, especially to the combustible and toxic medium equipment before the inspection of the atmospheric pressure vessel is carried out by the user of the equipment container. In addition, the equipment container not only needs to close the equipment valve, but also needs to use the blind plate of the equipment to close the valve so as to prevent the gas leakage into the container and cause the fire explosion or poisoning accident of the valve so as to cause the combustible or toxic gas to leak into the container.

WNS 1 ton steam boiler steam electric boiler price is based on the number of horizontal gas-based, but some parts of the operating costs for the gas business is far greater than the cost of electricity, which requires companies according to their current form Decided. Especially for natural gas is also used in some places it can also be electricity, which requires companies to consider operating costs between the different fuels. Recently, there is a business side to things faster 1000kg electric steam boiler boiler Advisory procurement, the situation is also encountered above mentioned, there can be used either electricity gas. Fast boiler understand the actual situation of the enterprise, the accounting of the business more cost effective electricity or steam boiler. Drawn is that the enterprise with electric steam boilers that meet one ton of production. The current price of the boiler model is about 100,000.

As one of Beijing's air pollution emission standards of the most demanding urban, environmental control is very strict. Beijing primary school campus Emerald City as one of the cradles of socialist culture successor, in terms of the quality of students' learning environment is put emphasis on one hundred percent. October 2017, Beijing primary school campus Emerald City with my company, signed a two Thalia T6 series vacuum hot water boiler for winter heating use.