10 Ton Gas Steam Boiler For Sell


10 Ton Gas Steam Boiler For Sell

Contrast gas 10 ton steam boiler for sell and gas steam boiler? Which is more cost-effective? There are new users will ask gas steam boiler and gas steam boiler which is more cost-effective in a number of economic operation? Believed to be ready to buy a steam boiler of every business relationship or personally, with you today, I will work together to analyze these two boilers in operating costs to do a comparison. First, the first point to analyze procurement costs: Because gas steam boiler in the annex above techniques and configurations to be clear leadership and gas steam boiler, gas steam boiler supporting a dedicated burner, a burner just put the cost price opened, so that the same tonnage of steam boilers, steam boilers high gas prices than gas steam boiler more. The second point to analyze construction costs: The costs mainly from the boiler room, boiler tubes of steam investment funds. In which the gas steam boiler because more appropriate auxiliary equipment, so in the boiler room construction funds to be more. There is a gas steam boiler automatic control operation, and automatic alarm and automatic protection function. Connected to the gas pipeline, the burner will automatically supply costs can effectively save staff. Gas-fired steam boiler because of the need of coal on the program, so in terms of personnel expenses wage will be larger. The third point to analyze the environmental cost: major review means that now more stringent gas steam boiler. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used. The fourth point to analyze fuel costs: gas steam boiler will be much higher than the steam boilers in gas fuels. After analyzing the above four points of view than the gas steam boiler Gas steam boiler in order to save more on operating costs, but gas steam boiler environmental protection, now increased pollution than gas steam boiler in environmental protection in recent years so the state more stringent control of environmental pollution, so in accordance with the requirements of environmental protection point of view has an advantage gas steam boiler.

Henan miss you Jujube Industry Development Co., Ltd. is mainly engaged in dates, nuts and other healthy food research and development, procurement, production and sales operations; jujube industry's first listed company. I miss you date industry is committed to providing health and hygiene products for people to date, in 2017, I miss you date industry decided to buy a few new clean and green, can provide high-quality 10 ton steam boiler for sell steam. Carefully selected is determined in cooperation with the fast boiler, signed two separate 10 tons of steam condensing gas steam boiler (WNS10-1.25-Y.Q).

Fuel gas control step and the blowing process air volume of the total fuel gas 10 ton steam boiler for sell steam boiler is achieved by adjusting a liquid coupling scoop blower. Organization fuel gas steam boiler combustion, is to make a, air pressure, air flow of secondary air with the good. Adjusting the amount of primary air should meet it carries the fuel into the furnace ignition of volatile oxygen required, and to maintain a certain speed, and without clogging the fuel discharge pipe of the jet having a certain rigidity. Primary air volume is too large and too small, the wind speed is too high and too low, should be avoided. In addition to adjusting the secondary air of combustion of the fuel should ensure that the oxygen demand, but must maintain a certain wind speed and primary air is mixed with the master time should have a strong stirring and mixing coke penetrate "the Gray" kinetic , which requires the case may be, each layer of the secondary air flow rate, in order to achieve stable combustion and flue gas excess oxygen appropriate destination. Fuel gas steam boiler, secondary air with what is better? Primary air volume air volume of the total share is called the primary air rate. A small air fraction, pulverized coal is heated to at least the heat required for the ignition point, fire faster, but the amount of primary air to satisfy the principle of combustion of volatiles. Secondary air mixed with the primary air time to the right. If it is mixed before ignition, means an increase in the amount of primary air, so that the ignition delay; hypoxia combustion secondary air if mixed will make late after ignition; if secondary air is mixed all at one position, since the secondary air temperature well below flame temperature, the flame temperature decreases, the combustion slows down, causing the fire. Therefore, the secondary air mixed with fuel should be based on the nature of the combustion zone as required timely sent, so that the combustion of oxygen, and will not reduce the flame temperature to ensure complete combustion and ignition stability. One or two wind speed with what is better? Fuel gas steam boiler once the wind speed is high, the fuel gas stream will catch fire in places far away from the burner, the ignition point postponed; once the wind speed is too low, it will cause a blocked ducts, and ignition point is too far forward, the burner will burn , but also easy to coke near the burner.

Gas 10 ton steam boiler for sell loading, installation considerations gas steam boiler is a very wide range of special equipment, usually built in the boiler room. However, its load, the installation process, some issues must be taken, otherwise it may cause a certain degree of economic losses. 1, the process of handling and transporting gas in a steam boiler to be noted the following: the lifting capacity of the lifting device should be matched to the weight of the boiler Lifting. Can not be used for lifting has a length marked with a lifting lug can not be used should be chosen on the boiler rope, rope length to avoid inappropriate, leading to scratching furnace. In the loading, unloading and handling process must ensure that the boiler without any damage. 2, installation of boiler maintenance reserve space, make sure there is enough space for maintenance around the boiler. 3, the base gas steam boiler, the base of the boiler and precautions to be installed on the basis of 100-150mm above the floor of the boiler on the premises, subject to prior confirmation boiler manufacturing company with technical personnel, in accordance with the basis for construction drawings. Must stay out of anchor bolts embedded hole basis. Foundation must be able to withstand the weight of the boiler and the largest holding water amount. When the mounting base, must first be positioned. After the alignment adjustment in the end the length of two diagonal lines of the same base, then the entire tightening the fixing bolt. Base mounting reference line marked for reference. 4. General Precautions Be careful not to tilt too boilers and accessories and be impact. Can not be placed outside the boiler fuel. Do not dirty oil and water boilers should generally be installed in a separate boiler room, the new gas steam boiler room should not be connected to the house. A boiler can not be connected, (B) and (C) use of flammable liquid fire risk room. If the production plant is connected to the other, separated by a firewall application. 5, fire resistance rating of the boiler room of the building and fire safety requirements should be consistent with "architectural design code for fire protection" and "design of tall buildings for fire protection" requirements. Gas-fired steam boiler room on the ground should be smooth, non-flammable, no water, load-bearing foundation should meet the requirements. Gas-fired steam boiler supply voltage should be stable, to avoid burn electrical components. The voltage instability, is recommended to install regulators. To set the boiler room ventilation equipment, to maintain the boiler temperature at 50 ° or less.

Other Products