1 Ton Gas Steam Boiler Supplier


1 Ton Gas Steam Boiler Supplier

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.

The design of the boiler room fire interval is how much? Section 13.1.1 boiler fire hazard classification and fire rating should meet the following requirements: a room, boiler production plant belongs to class D, to the 1 ton steam boiler supplier rated evaporation 4t / h, when the hot water boiler rated output is greater than 2.8MW, boiler room building fire resistance rating of not less than two; steam boiler equal to or less than the rated evaporation 4t / h, when the hot water boiler is equal to or less than the rated output 2.8MW, between the boiler building fire resistance rating of not less than three; II. when the inter-tank, and a pump room between the oil heater are class C production plant, its construction fire resistance rating of not less than two, disposed within said room between the auxiliary boiler room, a room should be set apart from other firewall; III. between the gas regulator production plant belonging to Group a, which is not less than two building fire rating, should be provided between the boiler room and the immediate neighborhood regulator firewall spaced boiler room, which doors open outwards and should not be passed directly the boiler room, the ground should not spark floor. Referring again to the provisions of Article 5.2.2 GB50016-2006 "architectural design code for fire protection," according to fire resistance rating.

10 t 10 t introduce gas boiler gas boiler 1 ton steam boiler supplier dedicated configuration computer controller, all Chinese, a large screen, backlit LCD display strong, rich display, operating status of the controller and the collected pressure, water and other states may be accurately visually displayed. Complete control functions, with intelligent boiler water level control, steam pressure control, low-limit water level alarm and interlock protection, high water level alarm, ultra-high pressure steam alarm and interlock protection, automatic control functions. Very convenient to use, may be provided continuously, the timing of the two states, the timing can be divided into four time periods, the boiler regular boot, time off, without full fireman, usually only have to press the start key turned on, press the stop button to stop very easy. Features: imported burner, automatic programmed control, automatic purge blower, electronic auto-ignition, spontaneous combustion and gas, (air) to automatically adjust the proportion of oil wind, good atomization, combustion, low NOX, energy saving . Under normal circumstances, when the boiler steam pressure reaches the set value, the burner combustion is automatically stopped, when the steam pressure is below the set value, the burner is automatically started. When the abnormal phenomenon of the fuel, air intake, fault lights, the output sequencer will immediately stop the fuel, burner shut down automatically. Advantages 1,10 tons of gas steam boiler furnace design and manufacture Three-pass boiler, wet back, eccentric furnace, asymmetric structures, waveform furnace, so that the flame produced a strong disturbance, and increased radiation heating surface, increased strength heat transfer coefficient, and can effectively prevent metal thermal expansion and contraction resulting in reduced life of the device. 2, the whole high degree of automation, security improved. Run fully automated process, with automatic replenishment, water shortage, overpressure, automatic power off and alarm, leakage protection and other security systems. 3, the whole body as glass wool type insulation, light weight, good thermal insulation effect, less heat loss; protection system: (1) protect the boiler water level indicator and integrated design of the boiler, the appearance of a more compact appearance, function accurately display the boiler The actual body of water. Coupled with dual independent electronic water level control system to achieve ultra-low water level in the boiler, low water level automatic adjustment function, the normal water level, high water level, ensure that the boiler in a variety of unforeseen circumstances foolproof, secure home. (2) steam pressure protection ☆ pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switch, other control lines or automatic control chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; the pressure controller may be single or double fire burning fire the actual operating pressure regulator. ☆ safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

The purchase of gas-fired boiler, we are more anxious shopping center, but for gas-fired boilers are not very understanding. After the introduction of others, we understand each other fast boiler more comprehensive, and more trust fast boiler. After the boiler put into use, it turns out, party fast products fully meet the needs of our shopping centers. --customer feedback

Other Products