1 Ton Diesel Fired Boiler In Mexico


1 Ton Diesel Fired Boiler In Mexico

Matters needing attention and standard flow of 1 ton diesel fired boiler in mexico periodic sewage discharge operationOperational notes and standardized procedures for boiler periodic discharge: 1. Periodic Sewerage notices 1. The main value of the furnace should be contacted before the discharge is discharged, and the steam turbine can be approved before it can be carried out. 2. When discharging water level is normal, after discharge, check whether each sewage door is closed tight. 3. Sewerage doors should not be opened to more than 30s, can not open two or more sewage doors at the same time, in order to prevent damage to the water cycle. 4. Open the drain door slowly in case of water shock. In case of water shock, close the valve until the shock disappears, and then slowly open the drain door. 5. When operating the valve, you should stand on the side of the valve, strictly prohibited Right to the valve. II. Discharge operation flow 1. After receiving the scheduling task, labor protection supplies dressed neatly, with a special F wrench, on the spot open the general gate. 2. Open all the doors, contact the DCS screen of the furnace to open the corresponding discharge electric door, after the discharge, first close the second door, then close the door, one by one, one by one. All sewerage is over, close once door of each discharge and main gate of sewerage 3. When discharging water, we should pay close attention to the water level. If there is any abnormal water level or accident, the discharge should be stopped. For 2 hours, the door cores of each discharge door shall be checked for leakage, and if the drain is lost, the drain door shall be opened promptly once. Note by removing residue that may be stuck in the core of the door (boiler principal value should be contacted before operation): the whole drainage process should be in close contact with the DCS operator.

The eco-friendly 1 ton diesel fired boiler in mexico produced by our company can be fueled by diesel, gasoline, liquefied petroleum gas (LPG), liquefied gas, natural gas, (LNG), methanol and so on. The following is a comparison of several kinds of fuels. Fuel point comparison: diesel fuel: ignition point 220 ℃; gasoline ignition point 427 ℃. However, gasoline is volatile, gasoline steam should be low to diesel fuel point, liquefied petroleum gas (LPG):) ignition point is 490 ℃, natural gas: burning point is 650 ℃.

Third, we should adjust the speed boost

During low nitrogen pressure inside the boiler rises, the need to go through several different stages, and the pressure is increased by certain units, the increase rate of the working medium corresponding saturation temperature is not the same, and the lower the pressure, the height of the unit pressure corresponding saturation temperature rise rate and the greater as the pressure increased, increase in the saturation temperature of the water will become increasingly smaller. Therefore, the national professional boiler manufacturers introduced low-nitrogen booster is very slow at the beginning of time, but wait until the situation under relatively high pressure can be suitably adjusted to improve the speed boost, because elevated pressure and elevated temperature has influence each other , it is not possible to separate transfers, must be considered to operate.

Six months from Hainan Sinochem Pharmaceuticals 1 ton diesel fired boiler in mexico equipment normally used in odd years, the equipment in good condition, our technical staff has repeatedly went to inspect the guidance. In the process of Hainan with the pharmaceutical companies, the other either for my company's product or service we are very satisfied with our company's reputation and expressed trust. --customer feedback

Other Products